MOXA IEX-402-SHDSL Series SHDSL Ethernet Extender Installation Guide
- June 6, 2024
- MOXA
Table of Contents
- MOXA IEX-402-SHDSL Series SHDSL Ethernet Extender
- Overview
- Package Checklist
- IEX-402-SHDSL Panel Layout
- Mounting Dimensions (unit = mm [inches])
- DIN-Rail Mounting
- ATTENTION
- DSL Port Connection
- Restore Factory Defaults Button
- LED Indicators
- DSL Speed/SNR LED Indicator
- Specifications
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MOXA IEX-402-SHDSL Series SHDSL Ethernet Extender
Overview
The Moxa IEX-402-SHDSL series Ethernet Extender consists of one
10/100BaseT(x) port and a DSL interface that provides an economical solution
for your Ethernet connections. Utilizing SHDSL technology over copper wires,
the IEX-402-SHDSL series supports data rates of up to 15.3 Mbps and long
transmission distance of over 8 km. Advanced managed functionality provides
highly reliable communication for networks.
The IEX-402-SHDSL series has a wide operating temperature range of -40 to
75°C, and supports 12/24/48 VDC redundant power supplies. The rugged hardware
design makes the IEX-402-SHDSL Series perfect for ensuring that your Ethernet
equipment can withstand critical industrial applications.
Package Checklist
The Moxa IEX-402-SHDSL series are shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance.
- IEX-402-SHDSL Ethernet Extender
- Panel mounting kit (optional—must order separately)
- Quick installation guide (printed)
- Warranty card
IEX-402-SHDSL Panel Layout
Front Panel View
- Terminal block for power input (PWR1, PWR2)
- Power input PWR1/PWR2 LED
- State LED
- Fault LED
- 10/100BaseT(X) Port
- DSL speed/SNR LED
- Detachable 2-contact DSL Port
- Link/ACT LED
- TP port’s 10/100 Mbps LED
- DSL Port(RJ-45/RJ-11 connector)
- CO/CPE LED
- Model name
- Grounding screw
- Power input PWR1/PWR2
- RS-232 Console Port
- DIP Switches
- Reset button
- Screw hole for wall mounting kit
- DIN-Rail Kit
Top Panel View
Rear Panel View
Mounting Dimensions (unit = mm [inches])
DIN-Rail Mounting
The aluminum DIN-Rail attachment plate should already be fixed to the back panel of the IEX-402-SHDSL when you take it out of the box. If you need to reattach the DIN-Rail attachment plate, make sure the stiff metal spring is situated towards the top, as shown in the following figures.
STEP 1: Insert the top of the DIN-Rail into the slot just below the stiff
metal spring.
STEP 2: The DIN-Rail attachment unit will snap into place as shown below.
To remove the Moxa Ethernet Extender from the DIN-Rail, simply reverse Steps 1
and 2.
Wall Mounting (optional)
For some applications, you will find it convenient to mount the IEX-402-SHDSL
on the wall, as shown in the following figures.
STEP 1:
Remove the aluminum DIN-Rail attachment plate from the IEX-402-SHDSL rear
panel, and then attach the wall mount plates as shown in the diagram at the
right.
STEP 2:
Mounting the IEX-402-SHDSL on the wall requires 4 screws. Use the switch, with
wall mount plates attached, as a guide to mark the correct locations of the 4
screws. The heads of the screws should be less than 6.0 mm in diameter, and
the shafts should be less than 3.5mm in diameter, as shown in the figure at
the right.
NOTE Before tightening the screws into the wall, make sure the screw head
and shank size are suitable by inserting the screw into one of the keyhole-
shaped apertures of the wall mounting plates.
Do not screw the screws in completely—leave about 2 mm to allow room for
sliding the wall mount panel between the wall and the screws.
STEP 3:
Once the screws are fixed in the wall, insert the four screw heads through the
large parts of the keyhole-shaped apertures, and then slide the IEX-402-SHDSL
downwards, as indicated. Tighten the four screws for added stability.
Wiring Requirement
ATTENTION
Safety First!
Be sure to disconnect the power cord before installing and/or wiring your Moxa
Ethernet Extender. Calculate the maximum possible current in each power wire
and common wire. Observe all electrical codes dictating the maximum current
allowable for each wire size. If the current goes above the maximum ratings,
the wiring could overheat, causing serious damage to your equipment
Be sure to read and follow these important guidelines:
-
Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the wires are perpendicular at the intersection point.
NOTE : Do not run signal or communications wiring and power wiring through the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately. -
Use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together.
-
Keep input wiring and output wiring separate.
-
When necessary, you should label the wiring to all devices in the system.
Grounding the Ethernet Extender
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from the ground
screw to the grounding surface prior to connecting devices.
This product is intended to be mounted to a well-grounded mounting surface,
such as a metal panel.
Wiring the Redundant Power Inputs
Both power inputs can be connected simultaneously to live DC power sources. If
one power source fails, the other live source acts as a backup and
automatically supplies the IEX-402-SHDSL with power.
The two 2-contact terminal block connectors on the IEX’s top panel are used
for IEX’s two DC power inputs. The top and front views of the terminal block
connectors are shown here.
Step 1: Insert the negative/positive DC wires into the V-/V+ terminals
Step 2: To keep the DC wires from pulling loose, use a small flat-blade
screwdriver to tighten the wire-clamp screws on the front of the terminal
block connector.
Step 3: Insert the plastic terminal block connector prongs into the
terminal block receptor, which is located on IEX’s top panel.
Before connecting the IEX-402-SHDSL to the DC power inputs, make sure the DC power source voltage is stable.
Auto MDI/MDI-X Connection
The Auto MDI/MDI-X function allows users to connect the
IEX-402-SHDSL’s 10/100BaseTX ports to any kind of Ethernet device, without
needing to pay attention to the type of Ethernet cable being used for the
connection. This means that you can use either a straight-through cable or
cross-over cable to connect the IEX-402-SHDSL to Ethernet devices.
Communication Connections
IEX-402-SHDSL models have one 10/100BaseT(x) Ethernet port, and one DSL port.
10/100BaseT(X) Ethernet Port Connection
The 10/100BaseT(X) ports located on the IEX’s front panel are used to connect
to Ethernet-enabled devices.
Next, we show pinouts for both MDI (NIC-type) ports and MDI-X (HUB/Switch-
type) ports, and also show cable wiring diagrams for straight-through and
cross-over Ethernet cables.
MDI Port Pinouts
Pin | Signal |
---|---|
1 | Tx+ |
2 | Tx- |
3 | Rx+ |
6 | Rx- |
MDI-X Port Pinouts
Pin | Signal |
---|---|
1 | Rx+ |
2 | Rx- |
3 | Tx+ |
6 | Tx- |
8-pin RJ45
RJ45 (8-pin) to RJ45 (8-pin) Straight-Through Cable Wiring
RJ45 (8-pin) to RJ45 (8-pin) Cross-Over Cable Wiring
DSL Port Connection
The DSL port located on the IEX-402-SHDSL has two connection options. One is
the RJ45 connector interface (2-wire on pin 4 and pin 5), the other is the
screw detachable interface. Pinouts are illustrated below.
RJ11 (RJ45 connector) DSL Port Pinouts
Pin | Signal |
---|---|
1 | – |
2 | – |
3 | – |
4 | Ring |
5 | Tip |
6 | – |
7 | – |
8 | – |
Wiring the 2-Contact DSL Port
The 2-contact terminal block connectors on the IEX’s top panel are used for
the IEX’s DSL port wiring. Top and front views of the terminal block
connectors are shown here.
Step 1: Insert the wires into the Ring/Tip terminals
Step 2: To keep the wires from pulling loose, use a small flat-blade
screwdriver to tighten the wire-clamp screws on the front of the terminal
block connector.
Step 3: Insert the plastic terminal block connector prongs into the
terminal block receptor, which is located on the IEX’s top panel.
RS-232 Console Port Connection
The IEX-402-SHDSL has one RS-232 (10-pin RJ45) console port, located on the
top panel. Use either an RJ45-to-DB9 (see the cable following wiring diagrams)
to connect the IEX-402-SHDSL‘s console port to your PC’s COM port.
You may then use console terminal software, such as Moxa PComm Terminal
Emulator, to access the IEX-402-SHDSL’S serial console.
RJ45 (10-pin) Console Port Pinouts
Pin | Description |
---|---|
1 | DCD |
2 | DSR |
3 | RTS |
4 | GND |
5 | TxD |
6 | RxD |
7 | GND |
8 | CTS |
9 | DTR |
10 | – |
RJ45 (10-pin) to DB9 (F) Cable Wiring
RJ45 (10-pin) to DB25 (F) Cable Wiring
Restore Factory Defaults Button
Press and hold the Reset button for 5 seconds to load the factory default settings. Use a pointed object, such as a straightened paper clip or toothpick, to depress the Reset button. This will cause the STATE LED to blink once a second. After depressing the button for 5 continuous seconds, the STATE LED will start to blink rapidly. This indicates that factory default settings have been loaded and you can release the reset button.
NOTE Do NOT power off the Ethernet extender when loading default setting
DIP Switches Settings
The IEX-402-SHDSL series provides 4 hardware DIP switches for quick
configurations, based on terminal type (CO/CPE), DSL signal measurement type
(Speed/SNR), communication media type (ANNEX A/ANNEX B) and data rate mode
(STD/Turbo).
NOTE Reboot the system after changing any of the DIP switch configurations.
Auto-Negotiation Mode
The SHDSL Ethernet extenders operate in pairs. One of the units needs to be
configured as a CO and the other as a CPE. By factory default,
IEX-402-SHDSL are configured as COs.
To make configuration easier, the IEX-402-SHDSL supports CO/CPE auto
negotiation. Enable the factory setting CO mode on the CO/CPE DIP switch for
both connected extenders, and the system will auto-negotiate and assign CPE to
one of the devices in each pair.
IEX-402-SHDSL Series DIP Switches
The following table explains the default setting and meaning of each DIP switch.
DIP switch (CO/CPE)| CO(Central Office)
The default value. Designates the IEX-402-SHDSL as CO.
| CPE (Customer Premises Equipment)
Designates the
IEX-402-SHDSL as CPE role
---|---|---
DIP switch (SNR/ SPEED)| SNR(signal-to-noise ratio): The default value. The
DSL SPEED/SNR LED indicator will show SNR information when
this is enabled.
| SPEED:
The DSL SPEED/SNRLED
indicator will show speed when this is enabled.
DIP switch (ANN B/ ANN A)| ANN B (ANNEX B)
The default value. The device connects with European-type cables (0.4 mm).
| ANN A (ANNEX A)
The device connects with U.S.-type cables (0.5mm)
DIP switch (STD/ TURBO)| STD:
The default value. The data rate follows defined standard mode value
| TURBO:
The data rate follows the defined Turbo mode value
LED Indicators
LED | Color | State | Description |
---|
PWR1
| ****
AMBER
| On| Power is being supplied to the power
input PWR1
Off| Power is not being supplied to the power
input PWR1
PWR2
| ****
AMBER
| On| Power is being supplied to the power input PWR2
Off| Power is not being supplied to the power
input PWR2
STATE
| ****
GREEN
| On| System has passed self-diagnosis test
on boot-up and is ready to run
Blinking
| 1. System is undergoing the
self-diagnosis test when booting up.
2. Blinks continuously when pressing the reset button 5 seconds to reset to factory default.
RED
| ****
On
| 1. System failed self-diagnosis on boot-up.
2. Link Fault Pass Through active, link
fault on the opposite unit
Blinking| Link Fault Pass Through active, link fault
on this unit
FAULT
| ****
RED
| On| System is in the event of failure, or is under quick inspection
Off| System is in normal operation
10/100M
(TP port)
| ****
GREEN
| On| The corresponding port’s link is active
Blinking| The corresponding port’s data is being
transmitted
Off| The corresponding port’s link is inactive
LINK/ACT
| ****
GREEN
| On| The corresponding port’s link is active at
Turbo speed
Blinking
| The corresponding port is auto negotiating for the optimized speed (Blink
every 1 sec)
The corresponding port’s data is being
transmitted
Off| The corresponding port’s link is inactive
AMBER
| On| The corresponding port’s link is active at
Standard speed
Blinking
| The corresponding port is auto negotiating for the optimized speed
(Blink every 1 sec)
The corresponding port’s data is being
transmitted
Off| The corresponding port’s link is inactive
CO/CPE
| GREEN| On| The IEX-402 is set as CPE
Off| The corresponding port’s link is inactive
AMBER| On| The IEX-402 is set as CO
Off| The corresponding port’s link is inactive
DSL Speed/SNR LED Indicator
Five Levels of SNR/SPEED Setting
| Turbo Speed
(K bits)
| STD Speed
(K bits)
---|---|---
5| 10297 – 15304| 4609 – 5760
4| 5697 – 10296| 3073 – 4608
3| 3457 – 5696| 2049 – 3072
2| 1025 – 3456| 769 – 2048
1| 192 – 1024| 192 – 768
| SNR (dB)
---|---
5| 18 – 30
4| 14 – 17
3| 10 – 13
2| 6 – 9
1| 3 – 5
Specifications
Technology
Standards| IEEE802.3, 802.3u, 802.3x, 802.1p, ITU-T
G.991.2, G.SHDSL and G.SHDSL.bis
SHDSL Data Rate| 192kbit/s to 15304kbit/s
Protocols| SNMPv1/v2c/v3, DHCP Client, SNTP, HTTP,
Telnet, Syslog, LLDP, Modbus/TCP, IPv6
MIB| MIB-II
Flow Control| IEEE802.3x flow control, back pressure flow control
Interface
RJ45 Port| 10/100BaseT(X) auto negotiation speed, F/H
duplex mode, and auto MDI/MDI-X connection
DSL Port| RJ-11 (RJ-45 connector) or
detachable 2-contact terminal block
Console| RS-232 (RJ45)
LED Indicators| PWR1, PWR2, FAULT, 10/100M (TP port),
STATE, CO/CPE, LINK/ACT, DSL SPEED/SNR
DIP Switches| Reset button, CO/CPE, SNR/SPEED, ANN B/ANNEX A, STD/TURBO
Power
Input Voltage| 12/24/48 VDC (9.6 to 60 VDC)
Input Current| 0.36 A @ 24 V
Connection| Two removable 2-pin terminal block
Overload Current
Protection
| Present
Reverse Polarity Protection| Present
Physical Characteristics
Housing| Metal, IP30 protected
Dimension| 35 x 130 x 105 mm
Weight| 0.29 kg
Installation| DIN-Rail, Wall Mounting (optional kit)
Environmental Limits
Operating Temperature| -10 to 60°C (32 to 140°F);
-40 to 75°C (-40 to 167°F ) for -T models
Storage Temperature| -40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
| 5% to 95% (non-condensing)
Altitude| Up to 2000 m, contact Moxa for products
guaranteed to function at higher altitudes
Regulatory Approvals
Safety| UL 508
EMI| FCC Part 15 Subpart B Class A, CISPR (EN 55032) class A
EMS| EN 61000-4-2 (ESD), Level 3
EN 61000-4-3 (RS), Level 3
EN 61000-4-4 (EFT), Level 3
EN 61000-4-5 (Surge), Level 3
EN 61000-4-6 (CS), Level 3
EN 61000-4-8
Shock| IEC 60068-2-27
Freefall| IEC 60068-2-32
Vibration| IEC 60068-2-6
Warranty| 5 years
ATTENTION
This device complies with Part 15 of the FCC rules. Operation is subject to
the following conditions:
- This device may not cause harmful interference.
- This device must accept any interference received including interference that may cause undesired operation.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>