Thank you for using our product. For better use, please carefully read this instruction. If you have any issues not mentioned here, please contact the provider. All parts of this booklet are reserved by our company, including words, pictures and graphics. Without written permission, no unit or individual shall extract, copy, translate or edit the content in this instruction.

Parts list

No. Name Quantity
1 Host 1
2 Power adapter 1
3 User manual 1
4 certificate 1
5 Installation sticker 1
6 Hexagonal wrench 1
7 3*12 Self-tapping screw 1
8 4*30 Cross countersunk self-tapping screws 4
9 Expansion pipes 4

Dimensional Drawing

Platform/ rm/Software Operating Instruction

Please mark the need for a software version when place the order. For more detailed platform/software

Appearance description

Instruction

Illumination intensity

The recognized face, of which, the illumination intensity “intensity” in short) shall not be lower than 30 Lux when the device put in a totally dark environment, the face illumination intensity, 0.5m distance to the device, is about 100 Lux. The nearer to the device, the higher the intensity is. If there is overexposure on the face, the face characteristics will be unable to be extracted and may lead to hard recognition.
Intensity test
The test standard is as shown on the picture: the angle between dotted line A and dotted line B is 90 ° , the test adopts the common light meter with full- spectrum, and applies U30 standard light source, adjust the distance between source light and test object, subject to the illumination intensity of the object face at this time.
Reference to intensity

Illumination intensity in actual scenarios
image and registered image; backlight, side-light and (Analysis: from the view of human eyes, the color changes on face skin may result in wrong recognition of identity; unclear exposure area, no matter large or small, may result in the identity judgment.) Light issues may lead to big differences between site strong light will influence the recognition experience.

Improvements

  1. Install the device in a place with little impact from light source.
  2. Add a registered image according to the site condition, and it is suggested to use this product to enroll images.
  3. Properly lower the threshold value according to usage.

Position

The device shall be installed in places avoiding backlight, side-light, and strong light.

This place, 3m away from the window, or does not influence by sunlight can be considered for installation
Backlight, side-light, or direct strong light, not suitable for installation.
Other areas, install in suitable places according to actual light impact.

Sunlight shines indoor
When the sunlight shines indoor through the window, the face recognition terminal device shall not be installed in shown black shadow area, instead, shall be installed in place with little sunlight impact, no side-light and no backlight. (Glass window can be deemed as no walls)

Glass window
If the room has glass wall, there is no shield for sunlight, then it is suggested to hang curtains over the window, and install the recognition. (Glass window can be deemed as no walls) Sunlight shines through the door, with glass window at one side Sunlight shines through the door, the device shall be installed at the place with shields and little light impact. Glass window can be deemed as no shields, the device shall be installed at the side without glass window or with a curtain hung.

Sunlight shines through the door
Sunlight shines through the door, the device shall be installed at the place with shields and little light impact.

Height

Suggested installation height (distance between the screen and the ground) is 1.4m, as their cogniZable body height range, 0.5m distance away from the device, is 1.3m-1.7m; the recognizable body height range, 1m distance away from the device, is 1m-2m. (There are some deviations)

Steps

Paste hole papers, and keep the horizontal line parallel with the ground and the red line 1.4m distance to the ground. Drill 4 screw holes on the wall according to the reminder of hole paper, drill 1 outlet hole according to wiring need. If the wall is a hard foundation, use an expansion pipe in the parts to knock into the hole.

Connect the power cable, network cable, and other wirings. ****

Move the support (device) to align the 4 holes on it with holes on the wall, and use the screws to fix the support (device) on the wall.

Attention: If the wall has a hard foundation, self-tapping screws shall be used together with expansion pipe; if the wall has a soft foundation, use self-tapping screws directly.
Fix the device, manually adjust the device angle to reach the optimal recognition angle.

Wiring connection

Wiring for magnetic door

System installation schematic drawing for magnetic door
Wiring for automatic door

System installation schematic drawing for automatic door

Wiring schematic drawing for touching switch of magnetic door

Wiring schematic drawing for sensor switch of automatic door

Wiring schematic drawing for the mechanical switch of magnetic door

Installation notes

1. When arranging the wires, if the 12V power supply cable of the host does not adopt the “Special power strip” and is in long-distance, resulting in large resistance, then abnormal phenomena may occur easily such as insufficient voltage (<11V), repeat restart, system crash and so on. The wiring connection of voltage metering is shown as follow.

2. The power adapter is put together with the device which is optional, such as EU standard, American standard, UK standard, and so on.

  • power supply for the host end, and abnormal phenomena like repeat restart, system crash may occur.

  • If the power is far away from the device, the power cable can be extended (strong current).

  • may cause repeat restart.

  • multi-strand cable in parallel or use copper core bold cable, to ensure voltage >11V.
    Attention: If using a network cable, the extension cable uses a 4-strand cable as a positive pole and a 4-strand cable as the negative pole.

  •  If not clear with how to extend, please contact the provider to change “Special power strip”.

Features

  • Characteristics
    Infrared and RGB dual-camera, live face detection; completely solve image frauds in all kinds of carriers; recognition accuracy is 99.99% (passing rate is 99.77% under 1% false accept rate; the passing rate is 99.27%under 0.1% false accept rate).

  • Store records in local
    (a) Device using cloud platform supports storing 100 thousand pieces of face images (smaller than 400KB), 1 million pieces of recognition records (0.45KB) and about 100 thousand pieces of site capture images; (b) Device using LAN support storing 100 thousand pieces of face images (each image by 100KB) and 1 million pieces of recognition records (including the latest 10 thousand pieces of site capture images).

  • Quick recognition speed
    Recognition speed less than 1s.

  • Secondary development (integrated)
    Support the interface connection in HTTP; supports 232 serial output, Wiegand 26 and

  • Complete functions
    saving the site images of face recognition and stranger detection.

  • High extensibility
    Supports deployment methods like public network and LAN; supports screen display

  • Temperature measurement
    The device should be used indoors to avoid the disturbance from the heat radiation source, Measurement distance is around 30-150cm, the range is around 30~45ºC, and the accuracy is ±0.5ºC.

  • Try to restart and reset
    When the device stops in some interface for a long time, users can plug out the can short circuit the tails or long-press RESET hole for 8-12s to restart the

  • Drop resistance
    Please avoid operations such as falling, breaking, bending, heavily pressing and so on.

  • Cleaning
    Please use a soft cloth or such materials, lightly wipe the display screen or panel, and to avoid scrubbing with water and cleaner.

  • Working temperature
    The normal working temperature for this device is -20ºC~50ºC, if the actual device. To ensure measurement accuracy, the device is recommended for indoor use to avoid interference of heat sources.

Do not dirty or damage the display screen with oil-water or sharp objects
Do not use the unknown power adapter to avoid burning out the device

FCC Warning

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance 20cm between the radiator & your body.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

UFACE User Manuals

Related Manuals