Seben 2301167 1200P Carbon Dioxide Detector Instruction Manual

June 6, 2024
Seben

Seben 2301167 1200P Carbon Dioxide Detector

INSTALLATION

First steps
Thank you for your purchase!
This product can be used to monitor the CO2 concentration, relative humidity, temperature and room air quality.

Packing list

  • CO2 monitor unit
  • USB cable for power supply
  • User manual
  • Mains adapter

Functions at a glance

  • Large display
  • Functions of the push-buttons
  • 15° angled construction for easy reading
  • Low-drift NDIR sensor with long service life
  • Acoustic alarm
  • Diagram with variable time zoom levels
  • CO2/RH/temperature monitor tracer
  • Auto calibration and manual calibration
  • Max/Min value display over a set time

Overview

Monitor sketch and component listSeben-2301167-1200P-Carbon-Dioxide-
Detector-1

Item Description Item Description
1 Front side 9 Good value
2 LCD 10 Low value
3 button 11 USB port
4  button 12 Hole for wall mounting
5  button 13 Hole for screws
6  button 14 Buzzer grille
7 Operating display 15 Label
8 High value 16 Holes for sensors

Operation and settings

  • Use the USB cable supplied to connect up the device. The device is ready for operation as soon as the countdown reaches zero. See p. 3.
  • Press to switch between time axis and CO2/RH/TEMP. The trend chart showsthe recorded values over time for each of the three parameters. See p. 5.
  • Reset to factory settings: Hold pressed for 3 seconds until an acoustic signal sounds.
  • Press once to display the main menu. Press to select the desired function. See p. 7.
  • Press to switch between Persons and Plants mode . See p. 8.
  • Press to change the high/low alarm limits for persons and plants . See p. 11.
  • Press to switch from loud to mute . See p. 8.
  • Press to select °C or °F for the temperature display. See p. 11.

Instruction Manual

  1. Plug in the device using the USB cable supplied as shown  on the right.
  2. After connection, the operating display and the 3 LEDs flash in turn.
  3. The main display shows a countdown. You can use the product as soon as the countdown has reached zero. NO CALIBRATION necessary

LCD monitor

Item Name Item Name
17 CO2/RH/TEMP chart 23 Plants mode
18 Max. value of the chart 24 Persons mode
19 Min. value of the chart 25 Acoustic alarm ON/OFF
20 RH (relative humidity) 26 CO2 value in ppm
21 TEMP (Temperature in °C / °F) ****

27

| Displays the timeline of the chart
22| Main menu

Trend chart display
The trend chart displays the measured values to date for each of the three parameters  (CO2/RH/Temp). There are 4 modes that can be selected with the button: CO2, TEMP, RH and “Cycle symbol” (-> alternates automatically between CO2/Temp/RH).Seben-2301167-1200P-Carbon-Dioxide-
Detector-4

The available zoom levels for all the parameters CO2/RH/Temp and the increments in the different levels can be seen in the table below:

Zoom level (time interval) Time per increment
1M (minute) 5 sec/increment
1H (hour) 5 m/increment
1D (day) 2 h/increment
1W (week) 0.5 d/increment

Max/Min
Two numerical indicators can be seen in the top right-hand corner of the display:
MAX and MIN. When the zoom level is changed, the MAX and MIN values reflect the highest and lowest values in the table for the selected parameter (CO2, RH and Temp).

Functions in the main menu

Seben-2301167-1200P-Carbon-Dioxide-
Detector-5

To select a function, press while it is underlined by the flashing cursor. Note that if no  button is pressed within 1 minute, the main menu disappears and the device returns to normal mode. Seben-2301167-1200P-Carbon-Dioxide-
Detector-6Seben-2301167-1200P-Carbon-Dioxide-
Detector-7 Seben-2301167-1200P-Carbon-Dioxide-
Detector-8 Seben-2301167-1200P-Carbon-Dioxide-
Detector-9

Specifications

Typical test conditions: ambient temperature: 23 +- 3°C, RH=50%~70%, altitude= 0~10 metres

Measurement Specifications
Operating temperature 32°F ~ 122°F (0°C ~ 50°C)
Storage temperature -4°F ~ 140°F (-20°C ~ 60°C)
Relative humidity 0-95% (non-condensing)

CO2 measurement
Measuring range| 0-5000 ppm
Display resolution| 1 ppm (0-1000); 5 ppm (1000-2000); 10 ppm (>2000)

Precision

| 0~3000 ppm: ± 50 ppm ± 5% of the reading (take the max. value)
(>3000) ppm: ± 7% of the reading
Repetition accuracy| 20 ppm at 400 ppm
Temperature compensation| ±0.1% of the reading per °C ±2 ppm per °C, referenced to 25°C
Reaction time| < 2 min for 63% of the level changes and < 4.6 min for 90%
Warm-up time| < 20 seconds
Temperature measurement

Operating temperature| 32°F ~ 195°F (0°C ~ 90°C)
Display resolution| 0.1°F (0.1°C)
Reaction time| < 20 minutes (63%)
RH (relative humidity) measurement
Measuring range| 5 ~ 95%
Precision| ±5%
Display resolution| 1% main menu display, 0.1% max/min display
Operating voltage| 5±0.25 V DC
Dimensions| 1209035 mm
Weight| 170 g (6.0 oz) (without AC adapter)

Annex

No. Meaning Value for high/low alarm Variable
0 Persons mode 800-1200 ppm Yes
1 User-defined plants 600-900 ppm Yes
2 Beans 600-900 ppm No
3 Chillies 800-1000 ppm No
4 Cucumbers 1000-1500 ppm No
5 Grapes 800-1400 ppm No
6 Orchids 800-1400 ppm No
7 Potatoes 1200-1800 ppm No
8 Strawberries 800-1200 ppm No
9 Tomatoes 800-1200 ppm No

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals