PHILIPS ProChamber Valved Holding Chamber
OVERVIEW
Cleaning instructions
Prior to first use and once each week, wash ProChamber and optional mask according to the cleaning instructions.
- Remove the MDI adapter. Remove the optional mask.
- Soak parts for 15 minutes in warm water with liquid detergent. Agitate gently.
- Rinse with clean water and shake out excess moisture. Let all parts air dry thoroughly.
- Replace the MDI adapter (and optional mask) when completely dry and ready for use.
- Masks Detachable masks are available in the following sizes for patients who are unable to use ProChamber with the mouthpiece alone. Ensure you use the correct mask.
Accessories
- Pediatric mask
- Small Pediatric mask
- Medium Adult mask
- Large
Recommended Ages
- 0-18 months
- 12 months-6 years
- 6 years +
chamber and Masks are not made with natural rubber latex.
Intended use
ProChamber is intended to be used in combination with Metered Dose Inhalers
(MDIs) to assist in respiratory drug delivery. ProChamber can be used by all
patients using MDIs, i.e. children and adults. Settings for use include the
home, clinics, and hospitals.
ProChamber should be replaced after 1 year of use.
ProChamber product dimensions: Length 5.75”(146 mm), Diameter 2” (50.8 mm)
Symbol glossary
Date and country of manufacture, to indicate the date on which a product was manufactured, and to indicate the country of manufacture of the product
- Manufacturer indicates the medical device manufacturer Indicates that relevant information for use of the product is available in electronic form
- Operator‘s manual Attention: consult instructions for use
- Catalogue number Indicates the manufacturer‘s catalogue number so the medical device can be identified
- Medical Device Indicates that the device is a medical device
- Unique Device Identifier Indicates the device unique device identifier information
- Packaging unit To indicate the number of pieces in the package
- Authorized Representative in the European Community
- Authorized importer in the European Community
CAUTION: Federal law (USA) restricts this device to sale by or on the order of a physician or licensed healthcare professional.
CAUTION: Prior to use, read these instructions thoroughly. If you do not
understand them, please contact your home care provider or healthcare
professional. If you need to contact Philips Respironics directly, contact
International customer service at
1-800-345-6443 (the USA or Canada only)
or
+1-724-387-4000 or go to
www.respironics.com to find your local customer service contact information.
INSTALLATION
- Adult supervision is necessary when a child uses ProChamber. Do not allow children to play with this product.
- Only disassemble parts according to the cleaning instructions.
- If parts are damaged or missing, do not use and replace them immediately.
- Ensure exhaust valves are seated properly as shown in Fig. A.
- Dispose of this device in accordance with local collections and recycling regulations. For more information visit www.philips.com/recycling.
- An electronic copy of these instructions can be found at: www.philips.com/IFU.
- Any serious incident that has occurred in relation to this device should be reported to Philips and the competent authority of the Member State in which the user and/or patient is established.
- Read the instructions that came with your medication before using ProChamber (a valved holding chamber).
- Pull off the protective caps.
- Always check the inside of the chamber for any debris before use.
- Insert the MDI actuator into the chamber’s MDI adapter until it is securely inserted.
- If a mask is needed, slide the mask onto the chamber mouthpiece until it is completely over the mouthpiece.
- Shake the chamber with the MDI actuator in place 4 or 5 times or follow the instructions for use that came with the medication.
- Place the chamber in your mouth and form a seal with your lips around the mouthpiece. Exhale. Actuate the MDI, and immediately begin to inhale. Breathe in slowly. Hold breath for 8-10 seconds.
- Or if using a mask, press and hold the mask against the face for at least 6 breaths following actuation of the MDI.
- Repeat steps 5-6 after 1 minute if additional medication doses have been prescribed. Store ProChamber in a suitable container when not in use.