AMERICAN EXCHANGE 6005-01 IOT Gateway
Revision History
Version | Date | Change Description | Author |
---|---|---|---|
V1.0 | 2020/12/1 | Initial Release | S. Turner |
V1.2 | 2020/2/1 | Addition of Minusforty Label | S.Turner |
Purpose
This document describes the basic functions and physical interfaces of the IOTGateway and is intended to guide users through the installation and configuration process. .
Introduction
The IOTGateway is designed to connect a variety of commercial devices such as refrigerators and freezers to the Internet. The IOT Gateway supports connection to the cloud via Ethernet, Wi-Fi or LTE interfaces and can connect to a suitable industrial device via a TTL Modbus interface.
After correctly configuring, the IOTGateway will periodically connect to the industrial device, monitor operational parameters (via the TTL Modbus interface) and upload data to the cloud monitoring platform.
IOTGateway External Images
Electrical Specifications
External DC Power | +6V to +18V DC |
---|---|
USB Power | +5V (USB) |
LTE Modem | LTE B2/B4/B5 |
Wi-Fi Connection | 802.11n 2.4GHz |
Max Power Consumption | 5W |
Size | 1739040mm |
Material | ABS |
External interface
Network interface
The IOTGateway supports following ways to connect to the internet:
- Wi-Fi
- Ethernet cable
- LTE Cellular network (optional, only available when the LTE modem and adapter board is correctly inserted);
- The IOTGateway supports Wi-Fi Mesh Networking, which means one IOTGateway can connect to the internet via another IOTGateway. In this mode the master IOTGateway can share its LTE connection to a number of other IOTGateways connected over Wi-Fi
Power supply interface
There are two interfaces for power supply: macro USB interface and external +12V D C Supply
- The IOTGateway can be powered directly through the TTL Modbus connector. The external supply range is from +6VDC to +18VDC (details of the connector pinout can be found in section 7)
- The TTL Modbus connector also provides an isolated power fail detection circuit to provide an alert when the main power fails and the IOTGateway is powered from the external battery backup supply.
- Macro USB power supply, powered by the 5V/1A DC.
| Warning: The IOT can only use one of the two power supplies at the same
time. Please don’t insert two power supplies at the same time, otherwise the
IOTGateway may be damaged.
---|---
External connectors
The following connectors are located in the covered section at the base of the IOTGateway
TTL Modbus Connector Pinout
The IOTGateway includes a TTL Modbus connector as shown below to allow the
Gateway to communicate with an external industrial device such as a
refrigerator or freezer.
LED indicators
The gateway has 5 LED indicators. The LEDs are located to the right side of the case as shown below. The LEDs are located inside the plastic case to protect the water resistance of the case and can not be seen from the exterior of the case.
-
Blue Indicator Light
○ Indicates that the IOTGateway is successfully powered. -
White Indicator Light
○ Indicates that the IOTGateway Wi-Fi interface is active -
Yellow Indicator Light
○ Indicates that the IOTGateway LTE interface is active -
Green Indicator Light
○ Indicates that IOTGateway is successfully connected to the Cloud Application -
Red Indicator Light
○ Indicates that a power fail has occurred and the unit is powered from the backup
Reset and Factory Reset
The RESET button is situated next to the ethernet slot on the gateway as shown below. The reset button can be pressed using a suitable tool such as paperclip.
a) If the RESET button is pressed for less than 30 seconds a gateway
REBOOT is initiated. The IOTGateway takes approximately -1 minute to
reestablish a network connection and come back online after a reset.
b) If the RESET button is pressed for more than 30 seconds a factory
RESET is initiated. The factory reset erases all network credentials in
addition to cleaning up local files and logs on the device. .
Copyright by Caribou Technologies. public 9 / 16
Procedure to Insert LTE SIM card
Please note: This procedure is only for IOTGateway with USB adapter and LTE module installed. The SIM card installation procedure is outlined below.
-
Start with the IOTGateway closed and face down.
-
Slowly slide the electronics assembly from the case being careful to prevent antenna cables being entangled. The SIM card connector is positioned to the underside of the LTE adapter board. Situate the SIM card as shown.
-
Push the SIM card into the connector using a suitable plastic tool.
-
Slide the electronics assembly back into the case being careful to prevent damage to internal components or antenna cables.
-
The SIM Card assembly process is now complete.
Network Architecture
The IOTGateway can be configured via a web application running on the device.
A Chrome browser is recommended to use for the configuration either from a
computer or mobile device. The web configuration tool running on the
IOTGateway provides a variety of configuration settings such as Wi-Fi SSID and
Password, LTE APN and Network connection (Wi-Fi, Ethernet, LTE)
As shown above, each base station has two interfaces with different IP
addresses. One of these IP addresses (referred to as the WAN port) is used to
connect to the internet network (MQTT server), which has a series of firewall
rule protection. The other IP address (referred to as LAN port, also known as
the intranet interface) is used for Wi-Fi hotspot broadcasting.
WAN Port: This interface supports Wi-Fi, ETH (network wire) or LTE
Network. The IOTGateway can connect to a router via Wi-Fi or LAN network
cable. Alternatively, if equipped with an LTE modem,the IOT Gateway can
connect to the network via the LTE modem In all cases the IP addresses are
assigned by routers/Cellular Network. The base station is connected to the
MQTT/HTTPs server through this interface. For WAN address IP address
configuration see “12.2.1 configuring WAN port network connection”.
LAN port: This interface only supports Wi-Fi. The default IP address of
this interface is 192.168.8.1, a PC or mobile device can connect to this
interface through Wi-Fi, or the next IOTGateway can connect to the internet
via the upper layer IOTGateway.
The gateway can only be configured through the Wi-Fi interface. Configuration
via the ethernet port is not possible.
Connect to IOTGateway
After power on, the IOTGateway will automatically broadcast the Wi-Fi SSID
using the default Wi-Fi name “IOTGW_????????????” where ???????????? is the
serial number for the IOTGateway.
-
Select the required IOTGateway. The Wi-Fi interface is secured using WPA encryption.
The default password is set to “IOTGateway”. The default password can be modified in the configuration utility. -
The default IOTGateway configuration IP address is 192.168.8.1
-
Login in to the IOTGateway configuration utility by typing http://192.168.8.1 in the browser. The following logon screen will be displayed.
-
Contact technical support for default Username and Password to log into the configuration utility
Network interface Configuration
Configure WAN interface
Tap on Network to go to the network configuration page. You can choose to connect to the internet network using Wi-Fi /Ethernet/LTE connection.
Connect to internet by Ethernet
The IP address can be assigned as DHCP or static configuration.
**Connect to internet by Wi-Fi
**
Note: The device cannot connect to an WPA2-PSK (AES) encrypted network.
Connect to a hidden Wi-Fi AP:
You may see some Wi-Fi names like mac addresses; it means that Wi-Fi has been
hidden. You should input the Wi-Fi name and password if you want to connect to
it.
If your Wi-Fi AP name does not appear in the nearby WLAN list, please try to reboot the IOTGateway. (you can reboot the device from the “Others” tab)
Connect to internet by LTE
Please make sure your SIM card is inserted into the IOTGateway.
Setting Up a Hotspot to share and LTE Network Connection
The Hotspot box must be enabled in the Network tab to allow for LTE network sharing. If hotspot sharing has been selected, additional IOTGateways can connect to the LTE IOTGateway over Wi-Fi and access the internet via the shared LTE connection.
Configure IOTGateway Wi-Fi AP
The AP LAN IP address can be changed from the following screen.
Modifying the Web Portal Login Password
The following page can be used to configure a new user password
FCC Warning
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must
accept any inte rference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interferenceto radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm
between the radiator and your body.