blueiot BT1000-g Card Bluetooth Location Tag User Manual
- June 6, 2024
- blueiot
Table of Contents
- **Tag Introduction
- Tag Usage
- Basic function
- Operation Conditions
- Trouble Shooting
- Safety Instructions
- Disposal and Recycling Information
- Limited Warranty
- Statement on Intellectual Property Rights
- Responsibility Statement
- Product Parameters
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BT1000-g Card Bluetooth Location Tag
User Manual
**Tag Introduction
**
General
BT1000-g Card Bluetooth Location Tag (CBL Tag) is mainly used for locating
people. With BlueIOT anchor, it is able to realize personnel locating, alarm,
reminder, and other functions. Its appearance is small and exquisite. It is
simple and easy to carry and wear.
1.2. Panel
Tag Usage
Turn on
The first use of the tag, double-click the front panel button to boot. When turned on, the tag will vibrate and beep 4 times.
When turned on, the tag will remain active, the user can not turn it off. If
any need to close the tag, please contact the system administrator, realizing
through the BlueIOT anchor and related software.
2.2. Recharge
When using the tag, note that the tag battery should have power. The LED indicator on the tag flashes every 5 seconds to indicate the current battery level.
The indicator light flashes in blue and green, indicating that the charging is
normal;
The indicator turns to solid green, indicating that the battery is fully
charged.
The indicator turns red, indicating that the battery needs recharging as soon
as possible. If the battery is completely exhausted before charging, it will
take a while to get enough power to make the indicator light work.
Follow the steps below to charge:
- Please use the original power adapter and charging cable, check if they are in good condition, clean and dry
- Insert the Type-C port of the charging cable into the charging port on the bottom panel of the label
- Insert the USB port of the charging cable into the power adapter
- Power on
WARNING: Using the wrong size or a poor-quality charger to charge the tag may
cause the tag battery to swell, heat up, or even catch fire. Use the original
charger to charge the tag!
Please avoid leaving the battery of the device uncharged for a long time.
Basic function
Locating
After the tag is turned on, it automatically enters the normal mode of locating. In the normal mode, the tag sends a locating signal to the BlueIOT anchor at a certain refresh interval. The refresh interval defaults to 200 milliseconds. This value can be set on the service configuration software.
When the tag stays static for a long time, it will automatically switch to sleep mode. In sleep mode, the tag will enter a low power consumption status. The refresh interval for the tag to send locating signals to the anchor will be extended to 10 seconds; when the tag moves or vibrates, it will immediately get back to the normal mode from the sleep mode. The static time from normal mode to sleep mode is 15 seconds by default, and this value can be set on the server configuration software.
SOS Alarm
Press the tag’s alarm button and hold it for more than 3 seconds, the tag will upload the emergency alarm information. After the alarm takes effect, the LED indicator of the tag will flash orange, indicating that it is currently in the distress alarm status.
Tag Configuration
The tag can be configured on the service configuration software, and the instructions of are issued to the tag through the BlueIOT anchor. For specific configuration functions, please refer to the “Service Configuration Software Manual”
Swipe Card
The tag has a built-in RFID coil, which can be used for radio frequency identification through a card reader.
Data Privacy
Tag data will only be uploaded to the server designated by the user.
When using tags, please consider and abide by local regulations related to
data privacy.
Operation Conditions
Exposure to liquid The CBL Tag is not water-resistant. Always avoid
exposing CBL Tag to liquids and moisture.
Cleaning and care Keep CBL Tag clean and dry but avoid damaging CBL Tag.
Observe the following:
Don’t clean CBL Tag while it’s charging.
Don’t dry CBL Tag using any external heat source (for example, a hairdryer).
Don’t use cleaning products, ultrasonic cleaners, or compressed air when
cleaning your CBL Tag.
Disinfection The following situations should be strictly avoided when
disinfecting parts such as areas around the button and charging interfaces:
Spray or wipe the CBL Tag directly with disinfectant liquid (such as diethyl
ether alcohol, chlorine-containing disinfectant, peracetic acid, etc.).
Carry out fire, boiling, flowing steam, high heat steam, dry heat sterilization,
etc. on CBL Tags and accessories.
Place the CBL Tag under ultraviolet light.
Any other disinfection practices that may cause damage or safety issues.
Use the button Do not press the button on the CBL Tag hard or crack it
violently.
Charging cable If the cable is bent repeatedly in the same area, it could
become hard and brittle. Please roll up the electric wire into downy curve.
Please check the cables and connectors regularly to prevent them from
knotting, breaking, bending or other damages. If any damage is found, do not
continue to use the cable.
Operating temperature CBL Tag is designed to work best in ambient
temperatures between -10°C (14°F) and +60°C (140°F) and be stored in
temperatures between -20°C (-4°F) and +70°C (158°F). CBL Tag can be damaged
and battery life could be shortened if stored or operated outside of these
temperature ranges. Avoid exposing CBL Tag to dramatic changes in temperature
or humidity.
Trouble Shooting
- The CBL Tag will flash the status light once every 5 seconds. If the status light does not flash for a long time, please double-click the button. If the status light of the CBL Tag is still off, the battery power of your CBL Tag has been used up, or the CBL Tag is out of order. Please contact your system administrator in time.
- Bluetooth wireless may penetrate some objects to establish a connection, such as wooden boxes, shelves, hollow walls, etc. However, it may cause an increase in location error.
- If the CBL Tag you are wearing is squeezed hard or entered with liquid, resulting in the short circuit of the vibration motor. Please contact the manager in time in this case.
Safety Instructions
Failure to follow these safety instructions could result in electric shock, fire, injury, or damage to CBL Tag or other properties. Read carefully all the information about safety below before using the CBL Tag. The seller shall not be liable for any damages caused by misuse or violation of the instructions contained herein.
【 Safety 】
-
not use CBL Tags when you are close to gasoline or liquid. Strictly follow all the indicated instructions and tips when you are in the petrol station.
-
The CBL Tag is integrated equipment. Neither the battery nor the back cover can be removed. Removing the back cover of the CBL Tag may damage the battery and lead to material leakage that may cause allergic reactions.
-
This equipment and its accessories may contain some small parts.
Please keep the equipment and its accessories including the small parts out of reach of children. Children may inadvertently damage the equipment and its accessories, or swallow small parts that cause suffocation or other dangers. -
Do not store or transport equipment and its accessories in the same box with flammable gases, liquids or explosives.
-
When disinfecting the equipment, do not spray or wipe it directly with flammable liquid to avoid fire.
-
Never disinfect the equipment during the charging process to avoid equipment damage or casualties.
-
Keep the CBL Tag in a dust-free place when not using it, and do not leave it in an abandoned status. Please pay attention to the weather and environmental conditions (nature, dust, rain seeping, wet, rain, seawater, etc.). The recommended operating temperature range is -10°C (14°F) to + 60°C (140°F) and the storage humidity range is 5%-95%.
Damage might be caused when it is used in an environment exceeding + 60°C (140°F). -
The CBL Tag and the accessories comply with applicable surface-temperature standards and limits. However, even within these limits, sustained contact with warm surfaces for long periods of time may cause discomfort or injury. Continuous alert of the CBL Tag may make the equipment feel warm. Remove the CBL Tag if it becomes uncomfortably warm.
-
Please use the charger in the original package when charging. Usage of non-conforming third-party chargers may cause personal safety damage and/or battery damage.
【 Battery 】
- Never discard, replace or open the battery at will, nor try to penetrate the equipment with sharp tools, as the electrolyte inside the battery in the equipment may damage skin and clothes.
- The equipment should be stopped from using if it is noticed to be hot, smelly, discolored, deformed or in any other abnormal status.
- If the battery leaks, do not expose the leaked liquid to your skin or eyes. If exposed to skin or eyes, rinse immediately with clear water and take medical treatment at the hospital.
- Do not expose the batteries to high temperature or place it close to any heating equipment, such as sunshine, heater, microwave oven, oven and water heater etc. Overheating batteries may cause an explosion.
- Do not drill or incinerate the equipment or battery. Please consult the local waste treatment department in accordance with the applicable local regulations including laws and policies when disposing of your equipment/battery. Batteries must be recycled or disposed of separately from household waste.
【 Charging 】
-
Please charge the battery in accordance with the requirements of the instructions. Please use the provided (in the same product package) CBL Tag charging cable and power adapter. When charging, remember to place the CBL Tag, CBL Tag charging cable, and power adapter in a well-ventilated environment. Using a damaged CBL Tag
charging cable or charging when humidity is high may cause fire, electric shock, injury, or damage to the CBL Tag and other properties. -
Always keep the ports of the CBL Tag and power adapter clean. Without adult monitoring, do not let children charge the CBL Tag.
-
As long as the applicable surface-temperature standards and limits are met, CBL Tags, CBL Tag charging cables, and power adapters will function normally. However, please still try to avoid continuous contact with hot surfaces even within the indicated limits as this may lead to discomfort or injury. After the power supply is plugged in, the CBL Tag, the CBL Tag charging cable and the power adapter will gradually heat up, but will not break the indicated limits.
-
Avoid wearing a CBL Tag when charging, or allowing your skin to contact the CBL Tag, CBL Tag charging cable, or power adapter for a long time while charging. For example, when the CBL Tag is charging, or when the CBL Tag charging cable, or the power adapter is powered on, do not lie on it or place it under a blanket or pillow, etc. Please be especially careful if your body has conditions that affect your ability to sense heat. If the temperature of the CBL Tag makes you uncomfortable, please remove it.
【 Maintenance 】
Do not open the CBL Tag and try to repair it yourself. Disassembling the CBL Tag may cause damage injury. If the CBL Tag is damaged or out of normal status, please contact your seller in time.
【Warning】
Radiofrequency interference Observe signs and notices that prohibit or restrict the use of electronic equipment. Although CBL Tag is designed, tested, and manufactured to comply with regulations governing radio frequency emissions. Emissions from CBL Tag could potentially negatively affect the operation of other electronic equipment within a certain distance.
Medical equipment interference CBL Tag contains components and radios
that emit electromagnetic fields. CBL Tag has certain coverage of radio
frequency bands. These electromagnetic fields may interfere with medical
equipment, such as pacemakers and defibrillators etc. Consult your physician
and medical equipment distributor for specific
information related to your medical equipment and confirm whether you need to
maintain a safe distance between the medical equipment and the CBL Tag and the
CBL Tag charging cable. Should you have any suspects or doubts, you are
recommended not to use this product (including all parts and all accessories).
Explosive and other atmospheric conditions Charging or using CBL Tag n any environment with explosive risk is strictly prohibited. CBL Tag functionalities might be damaged or impaired when exposed to an environment with high concentrations of industrial chemicals. Obey all relevant signs, instructions, and restrictions.
Choking hazard Some CBL Tag accessories may present a choking hazard to babies or children. Keep them out of reach of babies and small children.
Skin sensitivities Some people may experience allergies or reactions when
their skin is touched by certain materials used in jewelry, watches, or any
other wearable items. This can be caused by allergies, environmental factors,
extended exposure to irritants, or other causes. If you have past experiences
with skin sensitivities, please take special care
when wearing CBL Tag. You might be more likely to experience irritations.
Keeping CBL Tag clean and dry could reduce the possibility of skin
irritations.
Equipment safety The CBL Tag contains high-sensitivity electronic components. Falling, burning, puncturing or rolling could cause equipment damage.
Bluetooth equipment may be prohibited on the aircraft. The use of Bluetooth equipment has to be compliant with the relevant regulations from the national radio management authorities and relevant aviation management departments.
Not medical equipment The CBL Tag is NOT designed as medical equipment
and should not be used as a replacement for professional medical assessment or
judgment.
It is not intended for use in the diagnosis of disease or other medical
conditions, or in the cure, mitigation, treatment, or prevention of any
medical / health conditions or disease. Please consult your healthcare
provider for all questions related to your health before considering using the
CBL Tag.
Disposal and Recycling Information
CBL Tag disposal and recycling
Your CBL Tag should not be disposed of with household waste. Dispose of your CBL Tag in accordance with local environmental laws and guidelines.
European Union—Disposal Information
The symbol above means that according to local laws and regulations your product and/or its battery shall be disposed of separately from household waste. When this product reaches its end of life, take it to a collection point designated by local authorities. The separate collection and recycling of your product and/or its battery at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment.
Limited Warranty
(Warranty information )
Warranty does not apply to:
- Surface damage, such as scratches, dents, and depressions.
- Consumables such as batteries, except if the product is damaged due to defects materials or manufacturing processes.
- Damage caused by accident, abuse, misuse, inflow, flooding, fire, or external factors.
- Damage caused from repairing by non-BlueIOT authorized warranty personnel.
- Damage caused by modification or alteration of the product without the seller’s written consent.
- In addition, the seller reserves the right to refuse the warranty application for products or services obtained and/or used in violation of the laws of any country. This warranty provides you with specific legal rights, but this right may vary from region to region. The seller will not be responsible for any accidental, special, indirect or derivative damage (which may result from the use, misuse, don’t know how to use, or product defects). The seller reserves the right to overhaul or replace (new products or newly overhauled replacement products) equipment or software. This is the sole and exclusive remedy for any breach of the warranty terms. Please consult your local seller ‘s authorized seller when applying for warranty service.
【Warranty card】
Product name (including spare parts) | Limited warranty period |
---|---|
CBL Tag (as entire product) | 1 year |
Accessories (e.g. adapter, charging cable) | No warranty |
*Non-human factors, one-year warranty period; the cost of logistics (shipment) shall be borne by the users.
Note: If your device is purchased through a local seller, please contact the
local seller for the warranty service acquisition method. If your device was
purchased directly by the manufacturer, please get in touch via: info@blue-
iot.com.
Disclaimer: Depending on the design of usage location/environment and the way
how it is used, there could be false positives due to tissue, walls,
structures, or other factors and false negatives due to bodily interference,
electromagnetic interference, or other factors. BlueIOT warranties that the
CBL Tag performs to the requirements listed on the CBL Tag spec sheet. All
sales are final.
Statement on Intellectual Property Rights
Copyright Statement
Copyright ©2020 BlueIOT (Beijing) Technology Co., Ltd. All rights reserved.
Any part of this manual, including text, pictures, graphics, etc., belongs to BlueIOT (Beijing) Technology Co., Ltd. Without written permission, any unit or individual may not extract, copy, translate, or modify this manual in whole or in part by any means. Unless otherwise agreed, the Company makes no representations or warranties of any kind, express or implied, with respect to this manual.
Trademark statement
“BlueIOT” trademarks, logos, and trademark combinations are registered
trademarks of BlueIOT (Beijing) Technology Co., Ltd.
Liability statement
To the maximum extent allowed by law, the products (including hardware,
software, etc.) described in this manual are provided “as is”, there may be
defects, errors or malfunctions, the company does not provide any form of an
express or implied warranty, The “BlueIOT” series of products (hereinafter
referred to as “equipment”) provided by our
the company is management aids, which cannot replace the safety management
system, measures, and rescue programs of dangerous operations, nor can they
replace the supervision system in operation management and measures.
During the use of this product, please remind the operator not to reduce
safety awareness due to the use of auxiliary tools, timely charge the device
when the device is low, and regularly check the device. If you have any
questions, please contact our company for repair or replacement.
Responsibility Statement
Disclaimer
-
The product is an auxiliary tool, which cannot replace any safety management system, measure, and rescue solution for hazardous operation or supervision system and measure for operation management. Please do not reduce safety awareness while using the product, and timely charge the product and check its operation state when the power is low.
-
Measurement data and results of this product are for reference only.
Products described in the Manual (including hardware and software) are all provided in the “current situation” within the maximum range allowed by laws, and there may exist defects, errors, or faults. The Company does not provide an express or implied guarantee in any form
or compensate for any special, incidental, accidental, or indirect
damages caused by using the Manual or products of the Company. -
The Company does not undertake any responsibility for any damage to person or property interests of one’s own or third party caused by failing to use the product according to the Manual and warning statement.
-
The Company does not undertake any responsibility for any product operation abnormality, information disclosure, or other problems caused by network attack, hacker virus infection, or other unknown risks due to Internet access during product use.
-
The product promoting pictures and advertisements are used only for instruction and promotion. Physical products prevail in all cases.
-
The data in the Manual are all theoretical values obtained by the internal lab of BlueIOT in specific testing environments. However, there may exist differences due to individual product differences, software version, using conditions, and different environmental factors, and actual using conditions shall prevail in all cases.
-
The Company will not send special notice in the case of being necessary to modify and adjust the above.
-
For more information, please contact info@blue-iot.com.
Product Parameters
BT1000-g Card Bluetooth Location Tag
Frequency Range| 2.4GHz – 2.485GHz
Positioning Precision| Average LOS precision up to 10cm
Refresh Rate| 5Hz by default
Status Indication| LED /vibration/buzzer
Size| 85mmx54mmx6mm
Weight| 30g excluding accessories
Power Endurance| 3 months on average (©5Hz)
Battery Capacity| 480mAh/Rechargeable lithium battery
Charging Interface| USB Type-C
Charging Voltage| 5±0.1 V, 1000mA
Charging Time| 4 – 6 Hours
Operating Temperature| -10 – 60°C
Storage Temperature| -20 – 70°C
Operating Humidity| 10% – 90% Non-condensing
Storage Humidity| 5% – 95% Non-condensing
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment
The devices have been evaluated to meet the general RF exposure requirement, the device can be used in portable exposure conditions without restriction
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>