ADA 3D LINER 2V Line Laser Level Instruction Manual
- June 6, 2024
- ADA
Table of Contents
Operating manual
Line Laser Model: 3D LINER 2V,3V,4V
3D LINER
Manufacturer
Address: WWW.ADAINSTRUMENTS.COM
Kit
ADA 3D LINER 2V,3V,4V, aluminum carrying case, laser glasses, alkaline
batteries, target, operating manual.
Applications
With ADA 3D LINER you can take horizontal and vertical marking. You can use
the instrument inside and outside.
Specifications
Laser beam
Light sources
Laser safety class
Accuracy
Self-leveling range
Working range (with detector)*
Rotation/Fine adjustment
Power supply
Service time
Mounting thread
Operating temperature
Weight| 2V/3V/4V1H1D
635nm/floor point 650nm
2
±0.2mm/1m
±3°
radius 70m; without detector 40m
360°
3 X AA batteries
approx 8h with all lines ON
5/8″
-10°C ~ +40°C
0.9kg
---|---
Functional description
- 2, 3 or 4 vertical lines (the number of lines depends on the model of the instrument), 1 horizontal line, plumb down.
- Can be used both for operation indoor and outdoor. Use the receiver for outdoor operation up to 40 m.
- An electronic compensator ensures quicker self-leveling.
- When the instrument inclines more than ±2 the laser lines automatically gleam.
- 360° rotating fine adjustment mechanism makes it easier to find objects correctly.
- When turning off the power, a built-in locking system can automatically lock the compensator to avoid vibration during transportation.
Laser lines
Features
- Carry belt
- Power switch
- Vertical laser window
- Horizontal laser window
- Adjusting legs
- Circular level|
- Fine adjustment
Keypad
- Indoor/outdoor key (D)
- V laser lines switch
- Detector LED
- Power LED
Operation
- Take out the battery lid. According to the sign ” +,-“, insert four alkaline batteries or rechargeable batteries to the battery socket, then cover the battery lid.
- Set up the instrument on the floor or the tripod. When using a tripod, put the bottom part of the instrument on the tripod. Twist in the screw of the tripod into the centering nut of the instrument.
- If you hear the sound alarm while turning on the instrument, it means that the inclination of the laser level is more than ±2°. Adjust the instrument with the help of the instrument legs or tripod.
- Aim the down point on the selected point on the floor. Move the upper part of the instrument to adjust vertical lines. Use a fine adjustment mechanism for accurate adjustment of the instrument.
- ADA 3D Liner has several operating modes. The horizontal line is On when turning on the instrument. Press button V to select the desired operating mode: H/V/2HV/3VH. There is no plumb down in the H mode.
TO CHECK THE ACCURACY OF LINE LASER LEVEL
Set up the instrument between two walls, the distance is 5 m. Turn on the Line
Laser and mark the point of the cross laser line on the wall.
Set up the instrument 0,5-0,7m away from the wall and make, as described
above, the same marks. If the difference {a1-b2} and {b1-b2} is less then the
value of “accuracy” (see specifications), there is no need in calibration.
For example: when you check the accuracy of Line Laser the difference is
{a1-a2}=5 mm and {b1-b2}=7 mm. The instrument’s error: {b1-b2}-{a1-a2}=7-5=2
mm. Now you can compare this error with standard error.
If the accuracy of Line Laser isn’t corresponding with claimed accuracy,
contact the authorized service center.
TO CHECK LEVEL
Choose a wall and set laser 5M away from the wall. Turn on the laser and the
cross laser line is marked A on the wall. Find another point M on the
horizontal line, the distance is around 2.5m. Swivel the laser, and another
cross point of the cross laser line is marked B. Please note the distance of B
to A should be 5m. Measure the distance between M to cross laser lune, if the
difference is over 3mm, the laser is out of calibration, please contact with
the seller to calibrate the laser.
TO CHECK PLUMB
Choose a wall and set laser 5m away from the wall. Mark point A on the wall,
please note the distance from point A to ground should be 3m. Hang a plumb
line from A point to the ground and find a plumb point B on the ground. turn
on the laser and make the vertical laser line meet point B, along the vertical
laser line on the wall and measure the distance 3m from point B to another
point C. Point C must be on the vertical laser line, it means the height of C
point is 3m. Measure the distance from point A to point C, if the distance is
over 2 mm, please, contact the seller to calibrate the laser.
CARE AND CLEANING
Please handle measuring instruments with care. Clean with a soft cloth only
after any use. If necessary damp cloth with some water. If the instrument is
wet clean and dry it carefully. Pack it up only if it is perfectly dry.
Transport in original container/case only.
Note: During transport On/Off compensator lock (3) must be set to
position “OFF”. Disregard may lead to damage of compensator.
SPECIFIC REASONS FOR ERRONEOUS MEASURING RESULTS
- Measurements through glass or plastic windows;
- Dirty laser emitting window;
- After the instrument has been dropped or hit. Please check the accuracy.
- Large fluctuation of temperature: if the instrument will be used in cold areas after it has been stored in warm areas (or the other way round) please wait some minutes before carrying out the measurements.
ELECTROMAGNETIC ACCEPTABILITY (EMC)
- It cannot be completely excluded that this instrument will disturb other instruments (e.g. navigation systems);
- will be disturbed by other instruments (e.g. intensive electromagnetic radiation nearby industrial facilities or radio transmitters).
- Laser class 2 warning labels on the laser instrument.
LASER CLASSIFICATION
The instrument is a laser class 2 laser product according to DIN IEC
60825-1:2007. It is allowed to use the unit without further safety
precautions.
SAFETY INSTRUCTIONS
Please follow up on the instructions given in the operators’ manual. Do not
stare into the beam. The laser beam can lead to eye injury (even from greater
distances). Do not aim the laser beam at persons or animals. The laser plane
should be set up above the eye level of persons. Use the instrument for
measuring jobs only. Do not open instrument housing. Repairs should be carried
out by authorized workshops only. Please contact your local dealer. Do not
remove warning labels or safety instructions. Keep instruments away from
children. Do not use instruments in an explosive environment.
WARRANTY
This product is warranted by the manufacturer to the original purchaser to be
free from defects in material and workmanship under normal use for a period of
two (2) years from the date of purchase. During the warranty period, and upon
proof of purchase, the product will be repaired or replaced (with the same or
similar model at manufactures option), without charge for either part of
labor. In case of a defect please contact the dealer where you originally
purchased this product. The warranty will not apply to this product if it has
been misused, abused, or altered. Without limiting the foregoing, leakage of
the battery, bending, or dropping the unit are presumed to be defects
resulting from misuse or abuse.
EXCEPTIONS FROM RESPONSIBILITY
The user of this product is expected to follow the instructions given in the
operators’ manual. Although all instruments left our warehouse in perfect
condition and adjustment the user is expected to carry out periodic checks of
the product’s accuracy and general performance. The manufacturer, or its
representatives, assumes no responsibility for the results of faulty or
intentional usage or misuse including any direct, indirect, consequential
damage, and loss of profits. The manufacturer, or its representatives, assumes
no responsibility for consequential damage, and loss of profits by any
disaster (earthquake, storm, flood …), fire, accident, or an act of a third
party and/or usage in other than usual conditions. The manufacturer, or its
representatives, assumes no responsibility for any damage, and loss of profits
due to a change of data, loss of data and interruption of business, etc.,
caused by using the product or an unusable product. The manufacturer, or its
representatives, assumes no responsibility for any damage, and loss of profits
caused by usage other than explained in the users’ manual. The manufacturer,
or its representatives, assumes no responsibility for damage caused by wrong
movement or action due to connecting with other products.
WARRANTY DOESN’T EXTEND TO THE FOLLOWING CASES:
- If the standard or serial product number will be changed, erased, removed, or will be unreadable.
- Periodic maintenance, repair, or changing parts as a result of their normal runout.
- All adaptations and modifications with the purpose of improvement and expansion of the normal sphere of product application, mentioned in the service instruction, without the tentative written agreement of the expert provider.
- Service by anyone other than an authorized service center.
- Damage to products or parts caused by misuse, including, without limitation, misapplication or negligence of the terms of service instruction.
- Power supply units, chargers, accessories, wearing parts.
- Products, damaged from mishandling, faulty adjustment, maintenance with low-quality and non-standard materials, presence of any liquids and foreign objects inside the product.
- Acts of God and/or actions of third persons.
- In case of unwarranted repair till the end of the warranty period because of damages during the operation of the product, its transportation, and storing, the warranty doesn’t resume.
For more information, you can visit our website WWW.ADAINSTRUMENTS.COM or write a letter with your questions on info@adainstruments.com
WARRANTY CARD
Name and model of the product __
Serial number ____date of sale____
Name of commercial organization ____stamp of commercial
organization
Warranty period for the instrument explotation is 24 months after the date of
original retail purchase.
During this warranty period, the owner of the product has the right to free
repair of his instrument in case of manufacturing defects.
Warranty is valid only with original warranty card, fully and clear filled
(stamp or mark of the seller is obligatory).
Technical examination of instruments for fault identification which is under
the warranty is made only in the authorized service center.
In no event shall the manufacturer be liable before the client for direct or
consequential damages, loss of profit, or any other damage which occurs as the
result of the instrument outage.
The product is received in the state of operability, without any visible
damages, in full completeness. It is tested in my presence. I have no
complaints to the product quality. I am familiar with the conditions of
warranty service and i agree.
purchaser signature
Before operating you should read service instructions! If you have any
questions about the warranty service and technical support contact the seller
of this product
ADA MEASUREMENT FOUNDATION
WWW.ADAINSTRUMENTS.COM
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>