ECO16BTD Combined Thermostat Ensto
16A for DIN Rail Mounting
Instruction Manual RAK128
10.6.2021
© 2021 Ensto
|
---|---
|
Safety Instructions
Electrically skilled person
- The installation must only be done by an electrician with the appropriate qualifications.
- Read this manual carefully before starting the installation work.
- Follow the instructions in this manual, and make sure that the installation complies with national safety regulations, installation methods, and restrictions.
- The information provided in this manual in no way exempts the installer or user from the responsibility to follow all applicable safety regulations.
- This manual is a part of the product and must be stored in a safe location so that it is available for future installation and service.
WARNING
Danger of electric shock! Risk of fire!
- Disconnect the power supply before any installation and maintenance work on this thermostat and associated components.
- Do not switch on the power supply before the installation work is completed.
- Improper installation can cause personal injury and property damage.
- Do not operate a defective thermostat.
Delivery contents
- ECO16BTD combination thermostat
- Floor sensor
- Installation and Operating Instructions
Note! If you want to use the thermostat as a room or combination thermostat, you need to order an additional room sensor, product number ECOAC2.
Installation
Mount the thermostat onto a DIN-rail.
The thermostat does not have the main switch on the product itself. Install
the main switch elsewhere in the circuit.
Connect the thermostat in accordance with figure 1.
- The thermostat has screw connectors. The stripping length is 8mm.
- Connect the floor sensor to the Floor S1 and S2 connectors.
- Connect the room sensor to the Room S1 and S2 connectors.
- Connect external temperature control to the connector marked with ΔT. You can use any phrase for external temperature control. The default for external con- trol is 10 °C. You can modify the settings with the Ensto Heat Control application.
- A fault current switch with a nominal operating current of max. 30 mA must be installed.
Make sure that the heating load is equivalent to the thermostat power rating.
Measure the insulation resistance and the circuit resistance of the heating
load controlled by the thermostat. See the correspondence between temperature
and the sensor resistance value in Table 1.
Put the floor sensor cable in a dry protective tube between heating cables.
Note! Make sure, that there is no water in the protective tube.
Route the room sensor cable in a protective tube to the room to be heated.
Install the sensor in an appliance box for example with a cable tie. Install
the sensor at the height of approximately 1,5m measured from the floor.
Protect the sensor with a center plate, product number LS994BWWFI. You need
also a cover frame to complete the assembly, product number LS981WW85FI.
Commissioning and Operation
-
Turn on the thermostat with the separate main switch.
• The default mode for the thermostat is “Floor”. You can change the operation mode with the Ensto Heat Control application.
• The LED indicator B is green when the thermostat is on and the heating is off.
• The LED indicator B is red when the heating is on. -
Adjust the floor temperature by turning the adjustment wheel C. The thermostat switches on the heat, when the floor temperature measured by the floor sensor is lower than the set value.
-
The thermostat uses a 47 kOhm NTC floor sensor by default. If another type of the sensor is connected to the thermostat, change the sensor type accordingly with the Ensto Heat Control application ”Settings / Sensor type”.
-
When you use the thermostat in “Combination” or ”Floor” mode, the inbuilt fault detector detects if the floor sensor is defective or missing. The thermostat indicates the fault by blinking the red LED indicator B and blue LED indicator A alternatively. The blinking stops when the fault has been repaired.
User Interface, figure 2
A | Blue LED indicator |
---|---|
B | Red / Green LED indicator |
C | Adjustment wheel |
User Instructions for Ensto Heat Control Application
With this application, you can program and change the settings of your
thermostat. Bluetooth technology is used for wireless connections. You can
connect to one device at a time. The range in free space is approximately 5m.
Commissioning the Application
-
Download the Ensto Heat Control application from Apple Store or Google Play, figure 3.
Note! Pair your mobile device and thermostat only via the Ensto Heat Control application. DO NOT pair the thermostat using the device’s own Bluetooth menu. If you have paired the thermostat from the mobile device’s own Bluetooth menu, the application is not able to contact the thermostat. To correct the situation first remove the thermostat from the mobile device’s own Bluetooth menu and then pair it via the application. When paired via the application the connection works. The thermostat also appears in the mobile device’s own Bluetooth menu.
When pairing allow the Ensto Heat Control application to use the location service if the application requests it. It depends on the mobile device if the application needs permission to use the location service from the mobile device itself in order to use the Bluetooth low energy radio on the mobile device. If you do not give the permission, the application is not able to use the Bluetooth low energy radio and the application is not able to connect to the thermostat. The Ensto Heat Control does not collect the user’s location information and does not need the location service itself, but the application requires the Bluetooth low energy radio for wireless data transfer between the application and the thermostat. -
Open the application. In the “DEMO” mode you can practice using the application.
The Tutorial video shows the application’s features and guides you through the commissioning. At any time, you can go back to the Tutorial through the “Support” menu. -
After the Tutorial, pair your mobile device with your thermostat, figure 4:
• Switch on the thermostat with the separate main switch.
• Press the adjustment wheel C on the thermostat for 1 second [1]. The blue LED indicator A blinks [2].
• When the application has found your thermostat, your mobile device displays the default name ”New thermostat”.
• Press the ”New thermostat” button within 45 seconds [3].
• The blue LED indicator A turns off when the pairing is completed or 45 seconds is exceeded.
• Now you can find your thermostat in ”Devices / My devices”.
Home Screen, figure 5
Change the operation mode from the menu ”Settings/Mode”.
-
In ”Floor” mode the thermostat adjusts the heating according to the floor temperature. Select the floor setting temperature with the adjustment wheel C.
-
In “Room” mode the thermostat adjusts the heating according to the room temperature. In this case a room sensor is needed. Select the room setting temperature with the adjustment wheel C. In “Combination” mode the thermostat adjusts the heating according to the room temperature as well as according to the minimum and maximum floor temperatures. Define for the floor material appropriate minimum and maximum temperatures from “Settings / Floor temperature limits”.
-
If the floor temperature rises higher than the set temperature, the blue LED indicator A blinks four times per minute as a warning and the load switches off until the floor temperature has dropped sufficiently. This operation method is intended to protect sensitive floor materials such as parquet. Most parquet manufacturers recommend the maximum temperature of floor covering approximately 27°C.
Note! The floor sensor only measures the concrete temperature. The floor covering material temperatures are usually about 5°C lower than the concrete temperature, in which case the maximum limitation temperature can be set at about +32°C. It is recommended to set the limitation as low as possible and raise the value afterwards if necessary. However, each flooring material is unique, so when an accurate temperature limit is required, the floor temperature must be checked with a separate thermometer. -
In “Power” mode the thermostat adjusts the heating without sensors according to power. Select the length of the power cycle from “Settings / Power mode cycle time”. Select the desired heating power 0 – 100% with the adjustment wheel C. The heating operates in cycles of the selected period of time. The heating power (%) you select determines how long the heating is on and off during one cycle. For example, if you select 60 minutes for the cycle time and 60% for the heating power, the heating is on for 36 minutes and off for 24 minutes
Temperature Change with Calendar, Boost, and Vacation Functions
You can change the setting temperature adjusted with the adjustment wheel C on the thermostat.
- The change may be either a rise or a drop in temperature.
- The blue LED indicator A is on when the temperature change is connected.
You can carry out temperature changes in different ways depending on what kind of a change is needed.
- ”Calendar” is intended for weekly reoccurring events. For example, on weekdays you can drop the temperature overnight and while you are away, during weekends you may want to drop the temperature overnight. Note! When making settings for overnight, the night must be in two sections.
- ”Boost” is intended for a temporary temperature change. For example, after a shower, you can raise the temperature in the bathroom so that the floor will dry faster.
- “Vacation” is intended for long-term changes in temperature, e.g for a weekend break or an annual holiday.
The “Calendar”, “Boost” and “Vacation” buttons are on/off buttons. When
the temperature change is activated, the “Calendar” and “Vacation” buttons are
green, the “Boost” button is orange.
Press the button on the home display to enter the editing mode.
When the function ”Adaptive temperature change” is active, the thermostat will
advance the heating, so that the desired temperature has been reached at the
scheduled time. By default, the function is on.
External Temperature Control
You can use external temperature control if an external voltage is connected
to the thermostat.
- Disable / Enable the function from “Settings/External control”.
- From “Temperature” you can set the desired temperature value. The default temperature setting for external control is 10 °C.
- “Temperature change” can be either a rise or a drop in the setpoint temperature.
- The blue LED indicator A is on when the temperature change is in use.
- If the external control is enabled you cannot use the adjustment wheel for setting temperature.
Resetting the Factory Settings
Reset the factory settings:
- Press the adjustment wheel C on the thermostat.
- After 7 seconds, the blue LED indicator A starts to blink quickly.
- Paired devices, consumption information, and calendar settings are removed. The thermostat is in “Floor” mode.
Battery
-
The purpose of the battery is to maintain the time during power cuts. If the clock does not keep the correct time, the battery must be replaced. The battery change interval is several years and is usage dependent.
The battery may only be replaced by a skilled or instructed person.
Disconnect the power supply before replacing the battery. -
Replace the thermostat battery, figure 6.
• Remove the thermostat cover carefully by using a screwdriver.
• Replace the battery with the same type of battery as the original, CR1225.
• Put the cover in place.
• Dispose of the empty battery according to local recycling guidelines.
Figures
- Connection diagram
- User interface
- Installing the Ensto Heat Control application
- Pairing the thermostat with your mobile device
- Ensto Heat Control Home display
- Replacing the battery
- Dimensions
LED Indicators
Warranty
The warranty period for Ensto ECO thermostats is 2 years from the date of purchase but no longer than 3 years from the date of manufacture. Warranty conditions, see the product card www.ensto.com.
Disposal
Do not dispose of electrical and electronic devices including their
accessories with the household waste.
The product’s cardboard packing is suitable for recycling.
When a heating system is at the end of the life cycle the cables, conduits and
electronic components must be disposed of properly according to local
recycling guidelines.
Declaration of Conformity
Hereby, Ensto Building Systems Finland Oy declares that the radio equipment ECO16BTD is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.ensto.com.
Technical Data
Supply voltage | 230 V -15%, +10%, 50 Hz |
---|---|
Switch | Not on the device, a separate main switch must be installed |
Rated current | 16 A |
Maximum load | 3600 W |
Operating temperature range | -20 … +30 °C |
Thermostat adjustment range | 5 … 35 °C room 5 … 50 °C floor |
Floor max. limitation range | +25 … +50 °C |
Floor min. limitation range | +5 … +40 °C |
Floor sensor | NTC, 47 kf1/25°C, cable 4 m (extendable to 25 m) |
Sensor resistance values | Table 1, on page 2 (sensor not connected) |
Fuse | Max. 16 A |
Ingress Protection | IP20 |
Pollution degree rating | 2 |
Rated impulse voltage | 4 kV |
Power in standby | < 0,5 W |
Radiofrequency range | 2,4 … 2,483 GHz |
Radio max. power | +3 dBm |
Dimensions WxHxD | 36 x 90 x 58 mm |
Accessories
ECOAC2 | Room sensor: NTC, 47 kf2/25°C, cable 4m (extendable to 25 m) |
---|---|
LS994BWWFI | Blank center plate, white |
LS981VVW85F1 | Cover frame, 85mm, white |
Ensto Building Systems Finland Oy
Ensio Miettisen katu 2, P.O. Box 77
FIN-06101 Porvoo, Finland
Tel. +358 204 76 21
www.ensto.com
References
- Ensto – Leading Expert for Distribution System Operators
- Ensto – Leading Expert for Distribution System Operators
Read User Manual Online (PDF format)