microlife MT 410 Antimicrobial Thermometer Instruction Manual
- June 6, 2024
- microlife
Table of Contents
microlife MT 410 Antimicrobial Thermometer
Description of this Thermometer
- ON/OFF button
- Display
- Battery compartment cover
- Measuring sensor/measuring tip
- Cleaning and disinfecting area (thermometer probe only)
This Digital Antimicrobial Medical Thermometer provides highly accurate readings over the human body temperature range. At the same time, it reduces the microbial flora and minimizes the dispersion of contagious microorganisms, providing high safety to the user.
Antimicrobial Copper Properties
Surfaces made or covered by special copper alloys, have strong anti-
microbial properties against a wide variety of microorganisms*. Copper alloys
emit antimicrobial copper ions Cu+ that whilst in contact with microbes and
bacteria rupture their cellular membranes, thus destroying these
microorganisms. This activity reduces the microbial flora on the coated area
and – due to the «halo phenomenon» – simultaneously causes a drastic reduction
in pathogens on the remaining body of the thermometer. Thermometers containing
parts with antimicrobial copper alloys drastically reduce microbial flora,
minimizing the dispersion of contagious microorganisms and thus providing high
safety to the end-user. Efstathiou A. Panos «The Role of Antimicrobial Copper
Surfaces in Reducing Healthcare-associated Infections», European Infectious
Disease, Volume 5, Issue 2, Autumn 2011.
Important Safety Instructions
- Follow instructions for use. This document provides important product operation and safety information regarding this device. Please read this document thoroughly before using the device and keep for future reference.
- This device is only to be used for measuring human body temperature through oral, rectal or axillary. Do not attempt to take temperatures at other sites, such as in the ear, as it may result in false readings and may lead to injury.
- Do not use this device if you think it is damaged or notice anything unusual.
- We recommend cleaning this device according to the cleaning instructions before first use for personal hygiene.
- The minimum measurement time until the beep is heard must be maintained without exception! Consider those different measurement locations may require continued measuring even after the beep, see section «Measuring methods / Normal body temperature».
- Ensure that children do not use this device unsupervised; some parts are small enough to be swallowed. Be aware of the risk of strangulation in case this device is supplied with cables or tubes.
- Do not use this device close to strong electromagnetic fields such as mobile telephones or radio installations. Keep a minimum distance of 3.3 m from such devices when using this device.
- Protect the device from impact and dropping!
- Avoid bending the thermometer probe more than 45°!
- Avoid ambient temperatures above 60 °C. NEVER boil this device!
- Use only the commercial disinfectants listed in the section «Cleaning and Disinfecting» to clean the device to avoid damage to the device.
- We recommend this device is tested for accuracy every two years or after mechanical impact (e.g. being dropped). Please contact Microlife- Service to arrange the test.
WARNING:
The measurement result given by this device is not a diagnosis! Do not rely
on the measurement result only. Batteries and electronic devices must be
disposed of in accordance with the locally applicable regulations, not with
domestic waste. domestic waste. Read the instructions carefully before using
this device. Type BF applied part
Turning on the Thermometer
To turn on the thermometer, press the ON/OFF button 1; a short beep signals
«thermometer ON». A display test is performed. All segments should be
displayed. The last measurement reading will be shown on display 2
automatically for 2 seconds with the «M» icon. Then at an ambient temperature
of less than 32 °C, an «L» and a flashing «°C» appear at the display field 2.
The thermometer is now ready for use.
Function Test
The correct functioning of the thermometer is tested automatically each
time it is turned on. If a malfunction is detected (measurement inaccuracy),
this is indicated by «ERR» on the display, and measurement becomes impossible.
In this case, the thermometer must be replaced.
Using the Thermometer
Before use, keep this thermometer out of any physical contact, for at least
2 hours. This utilizes the antimicrobial copper properties, as described in
chapter «Antimicrobial Copper Properties». The use of anti-microbial copper is
a supplement to and not a substitute for standard infection control practices;
users must continue to follow all current infection control and cleaning
practices. We recommend cleaning the thermometer as described in chapter
«Cleaning and Disinfecting». Choose the preferred measuring method. When
taking a measurement, the current temperature is continuously displayed and
the «°C» symbol flashes. If the beep is heard 10 times and the «°C» is no
longer flashing, this means that the measured increase in temperature is less
than 0.1 °C in 16 seconds. To prolong the battery life, turn off the
thermometer by briefly pressing the ON/OFF button 1. Otherwise, the
thermometer will automatically turn off after about 10 minutes.
Storage of Measured Values
If the ON/OFF button 1 is pressed for more than 3 seconds when turning on
the thermometer, the automatically stored maximum temperature during the last
measurement will be displayed. At the same time, a «M» for memory will appear
on the display. About 3 seconds after the button is released, the temperature
value disappears and the thermometer is ready for measurement.
Measuring methods / Normal body temperature
-
In the armpit (axillary) / 34.7 – 37.3 °C
Wipe the underarm with a dry towel. Place the measuring sensor 4 under the arm into the center of the armpit so the tip is touching the skin and position the patient’s arm next to the patient’s body. This ensures that the room air does not affect the reading. Because the axillary takes more time to reach its stable temperature wait at least 5 minutes, regardless of the beep sound. -
In the mouth (oral) / 35.5 – 37.5 °C
Do not eat or drink anything hot or cold 10 minutes before the measurement. The mouth should remain closed up to 2 minutes before starting a reading. Position the thermometer in one of the two pockets under the tongue, to the left or right of the root of the tongue. The measuring sensor 4 must be in good contact with the tissue. Close your mouth and breathe evenly through the nose to prevent the measurement from being influenced by inhaled/ exhaled air. Approx. measuring time: 10 seconds! -
In the anus (rectal) / 36.6 – 38.0 °C
Carefully insert the measuring sensor 4 of the thermometer 2 to 3 cm into the anal aperture. The use of a probe cover and the use of lubricant is recommended. If you are unsure of this measurement method, you should consult a professional for guidance/training. Approx. measuring time: 10 seconds! -
In the anus (rectal) / 36.6 – 38.0 °C
Carefully insert the measuring sensor 4 of the thermometer 2 to 3 cm into the anal aperture.
The use of a probe cover and the use of lubricant is recommended. If you are unsure of this measurement method, you should consult a professional for guidance/training.
Approx. measuring time: 10 seconds!
Cleaning and Disinfecting
For disinfection in-home use environment, use a 70% Isopropyl alcohol swab, or a cotton tissue moistened with 70% Isopropyl alcohol to wipe surface pollutants off the thermometer probe (note: consider the application and safety instruction of the disinfectant manufacturer). Always start wiping from the end of the thermometer probe (approx. at the middle of the thermometer) towards the thermometer tip. After-wards the entire thermometer probe (see number 5 in the drawing) should be immersed in 70% Isopropyl alcohol for at least 5 minutes (max. 24 hours). After immersion, let the disinfectant dry off for 1 minute before next use. Avoid immersing or wiping the display to protect it from fading. The thermometer is not intended for professional use.
Battery Replacement
When the symbol (upside-down triangle) appears in the display, the battery
is flat and needs replacing. To replace the battery remove the battery
compartment cover 3 from the thermometer. Insert the new battery with the + at
the top. Make sure you have a battery of the same type to hand. Batteries can
be purchased at any electrical store.
Technical Specifications
This device complies with the requirements of the Medical Device Directive 93/42/EEC. Technical alterations reserved.
Guarantee
This device is covered by a 5-year guarantee from the date of purchase. During this guarantee period, at our discretion, Microlife will repair or replace the defective product free of charge. Opening or altering the device invalidates the guarantee. The following items are excluded from the guarantee:
- Transport costs and risks of transport.
- Damage caused by incorrect application or non-compliance with the instructions for use.
- Damage caused by leaking batteries.
- Damage caused by accident or misuse.
- Packaging/storage material and instructions for use.
- Regular checks and maintenance (calibration).
- Accessories and wearing parts: Battery.
Should guarantee service to be required, please contact the dealer from where the product was purchased or your local Microlife service. You may contact your local Microlife service through our website: www.microlife.com/support Compensation is limited to the value of the product. The guarantee will be granted if the complete product is returned with the original invoice. Repair or replacement within the guarantee does not prolong or renew the guarantee period. The legal claims and rights of consumers are not limited by this guarantee.