metos PROFF WD-N Water Dispenser User Manual
- June 6, 2024
- metos
Table of Contents
metos PROFF WD-N Water Dispenser
General
Carefully read the instructions in this manual as they contain important information regarding proper, effi cient and safe installation, use and maintenance of the appliance. Keep this manual in a safe place for eventual use by other operators of the appliance. The installation of this appliance must be carried out in accordance with the manufacturer’s instructions and following local regulations. The connection of the appliance to the electric and water supply must be carried out by qualifi ed persons only. Persons using this appliance should be specifi cally trained in its operation. Switch off the appliance in case of failure or malfunction. The periodical function checks requested in the manual must be carried out according to the instructions. Have the appliance serviced by a technically qualifi ed person authorized by the manufacturer and using original spare parts. Not complying with the above may put the safety of the appliance in danger.
Symbols used in the manual
This symbol informs about a situation where a safety risk might be at hand.
Given instructions are man-datory in order to prevent injury. This symbol
informs about the right way to perform in order to prevent bad results,
appliance damages or hazardous situations. This symbol informs about
recommendations and hints that help to get the best performance out of the
appliance. This symbol explains the importance of careful and regular cleaning
of the machine to meet hygiene requirements.
Symbols used on the appliance
This symbol on a part informs about electrical terminals behind the part. The
removal of the part must be carried out by qualifi ed persons only.
Checking the relationship of the appliance and the manual
The refrigerant in the appliance must fi rst be checked on the rating plate of
the appliance. The rating plate of the appliance indicates the serial number
of the appliance. If the manuals are missing, it is possible to order new ones
from the manufacturer or the local representative. When ordering new manuals
it is essential to quote the serial number shown on the rating plate.
Safety
Safe use of the appliance
The appliance must be connected to an earthed socket. When moving or servicing
the appliance, always unplug it from the power supply.
WARNING
The refrigerant and charge is declared on the rating plate. Refrigerant R290
(propane) is highly fl ammable. Handle equipment that contains R290 with extra
care. Under no circumstances should the value set at the factory of the
refrigeration unit be set colder. Chang-ing the setpoint can cause the
refrigeration unit to freeze and the actuators connected to it, such as the
taps, to break. At worst, water damage can result. ” Modifying the equipment
without the approval of the manufacturer invalidates the manufacturer’s
product liability. Dangerous situations may arise if the given instructions
are not followed. The manufacture declines all responsibility for any
operations carried out on the appliance without following the instructions in
this manual.
Disposal of the appliance
The appliance contains parts and components, the disposal of which requires
special treatment. Contact local authorities to obtain instructions on how to
dispose of the appliance.
Functional description
Intended use of the appliance
The appliance is intented for cooling and dispensing drinking water.
Structure and operating principle
WD, WD-E, WD-N, WD-EN, WD-2, WD-E2, WD-N2, WD-EN2 are free-standing models and
designed to be situated in a serving line. Models D-I WD ,D-I WD-E, D-I WD-N,
D-I WD-EN, D-I WD-2, D-I WD-E2, D-I WD-N2, D-I WD-EN2 are delivered without an
outer casing and are designed for insertion into a line structure.
Electronic faucet (models PWD-04A-E, PWD-04A-EN, D-I WD-E, D-I WD-EN)
The faucet is turned on and off by means of a solenoid valve actuated by a
photocell. When a glass is held within the photoce ll’s sensing range, the
solenoid valve opens and water starts to fl ow. The faucet turns off
automatically after the adjusted fl ow period. The faucet works best with a fl
at-bottomed glass.
Operating instructions
Operation
- Mechanical faucet: Push the lever with a glass.
- Electronic faucet: Hold a glass under the faucet.
After operation
Cleaning the exterior surfaces
Clean the stainless steel surfaces with neutral, liquid detergents. Abrasive or corrosive agents must not be used.
Cleaning the condenser (to be performed by a service technician)
Depending on circumstances, the condenser should be cleaned once a year or more often, if necessary. Condenser clogging is apparent when compressor running times get longer, the cooling effect decreases and the condensing temperature rises. Finally, condenser clogging can damage the compressor. When cleaning the condenser with a brush, be careful not to damage the condenser. The condenser can also be cleaned using a vacuum cleaner.
Replacing the fi lter (option) (to be performed by a service technician)
If the appliance is supplied with an optional fi lter, we recommend replacing
it at the intervals of 4800 litres or once the fi lter is clogged. The fi lter
is clogged when the water output starts to decrease and the water fl ow becomes
weaker. Depending on the frequency of use, the fi lter should be replaced ap-
proximately every six months.
- Holder
- Filter
- Cover
Cut off the incoming water and run water from the faucet to release the pressure. Screw the cover (3) off the holder (1). Remove the old fi lter (2). Insert a new fi lter inside the cover and screw the cover (3) to the holder (1).
Installation
General
The appliance is designed to function in locations with temperatures of 10°C
to 35°C. The appliance must not be installed close to appliances that generate
heat, e.g. ranges. If the water pressure at the installation site exceeds 5
bar, the device’s water connection must be equipped with a pressure reducing
valve
Storage
The appliance should be stored in a dry place, at a temperature over +1°C. If
the appliance has been exposed to a temperatures below 0°C, it must be drained
(allowed to melt). After melting, before taking the appliance into use, make
sure that there is no damage to or leakage in piping.
Unpacking the appliance
The appliance should be transported to the installation site in its transport
package. Do not remove pack-ing until just before installation to prevent dust
in the installation place from damaging the appliance. The appliance should be
stored and transported in an upright position.
Installation
The appliance should be placed in a well ventilated room. Avoid placing the
appliance in direct sunlight. The appliance must be installed in a vertical
position with an accuracy of ±3°. Greater skewness may cause malfunctions.
When installing D-I models care must be taken that the machinery is not
positioned directly on the floor, but an air gap of at least 10 cm is left
between the machinery and the floor. This is to make sure that water, possibly
dripping onto the fl oor, would not damage the electrical components of the
machinery and cause hazardous situations. The compressor is equipped with
damping of vibrations, but in some cases vibrations can transfer to other
structures. A rubber mat placed under the appliance can absorb vibrations and
noise (needed in special cases only). The thermostat has been set at the
factory for ordinary operating circumstances. When installing refrigerated D-I
models, special attention must be paid to condenser air circulation. Make sure
that the condenser air inlet is not blocked and that warm air can freely exit
the compressor compartment. The temperature of inlet air is of crucial
importance to the cooling effect of the appliance.
Ensure suffi cient air inlet/air circulation for the condenser.
Condenser air circulation Do not mount the condenser on a closed plinth, as this will prevent condenser air circulation. Air venting takes place below the appliance and air intake at the front. Do not block the condenser air inlets.
Opening for the drip basin (D-I models)
An opening must be made for the drip basin on the table top. The water cooler is installed inside the counter. The necessary openings are marked on the pictures with solid lines and the shape of the drip basin with broken lines.
Make a water connection between the faucet and the water cooler. Installation sequence:
- Assemble the faucet
- Attach the faucet to the drip basin
- Attach the pipe connector to the faucet
- Attach the pipe connector to the machinery outlet
- Connect the faucet and the machinery outlet with a CU-pipe Ø 10 mm (not included in delivery)
Connect the water cooler only to a cold water supply. A pressure reducer is
needed if the water supply pressure is above 5 bar. The connection of the
appliance to the water supply must be carried out by qualifi ed persons only.
NOTE. Do not remove the spacer ring of the electronic faucet during
installation!
Electrical connections
The appliance is designed to function in the electrical power network 1/N/PE
AC 230V 50Hz. Connect the appliance to the power supply with an earthed
socket.
First start up
The water tank of the cooler has to be filled before start up.
Note that the water tank has to be filled manually, it does not fi ll even
though the cooler is connected to the water supply. Fill the tank through the
pipe located behind the front panel. Check the water level on the pipe. The
tank volume i approx. 9 litres..
Adjusting the glass filling rate (mechanical faucet)
Water filling rate can be adjusted with the help of a screw (1) located on top of the faucet by turning the screw with a screwdriver. If, after installation, some air comes out of the faucet, allow water to run until no air is coming and the water is clear.
Adjusting the electronic faucet for the glass used
To be performed by an authorised service technician or installer.
Adjusting the water flow (electronic faucet)
To be performed by an authorised service technician or installer.
Troubleshooting
In case the appliance does not function as expected, review the following list of problems to fi nd out if the appliance can be put in order without a service call. In this way you can avoid unnecessary service calls and costs. In all enquiries, please contact the nearest Metos service. Most problems can be mana-ged on the phone.
POBLEM | POSSIBLE CAUSE | ACTION |
---|---|---|
No water comes out of the faucet | Water line obstructed (faucet is closed) |
Open the faucet
Not enough water in the tank| Check and fill
Too little water coming| Filter (option) clogged (water flow gradually
decreases)| Replace the filter
Water flow adjusted to a too low flow rate| Adjust the flow rate correctly
Too much water coming| Water flow wrongly adjusted| Adjust the flow rate
correctly.
Water is warm| Power cable is not properly plug- ged in the socket| Put the
cable properly in the socket
Defective fuse| Replace the fuse
Condenser covered by dust| Clean the condenser
Defective thermostat| Call the service
Defective compressor| Call the service
The cooler is installed in a too warm environmet or otherwice not suitable
location| Call the service
The appliance does not contain parts that can be serviced by the user. Service must be carried out by an authorised service company.
Technical specifications
- Refrigeration circuit diagram
- Connection diagram S00354 A3 (Mechanical faucet)
- Connection diagram S00196 A2 (Electronic faucet)
- Dimensions, machinery
- Installation drawing
ITEM | TYPE | SPECIFICATION |
---|---|---|
Electric connection | Cooling and electronic | 1/N/PE AC 230V 50Hz |
Power input | Cooling and electronic | 0,16 kW |
Extraction capacity | Cooling | 180 W, +7°/54° |
Exterior | Cooling | R290 |
Ulkovuoraus | All | Stainless steel |
Control unit | Cooling | Thermostat |
Capacity | 40 litres / hour | |
Drain | Floor drain | |
Water connection | Cold water, max. 5 bar | |
Sensing range | Electronic | preset, range 0-40 cm |
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>