Puravent PF400 Power Ventilator User Manual

June 6, 2024
puravent

Puravent LOGO

Puravent PF400 Power Ventilator

www.eipl.co.uk

Get In Touch

Call: 0845 6880112
Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH

INTRODUCTION

This user manual tells you how to operate the PF400. Please read thoroughly before operating the unit. If you have any questions please contact our Customer Services Department at the address shown at the back of this manual.

IMPORTANT
Your PF400 is packed in a plastic wrapping – please ensure that it is disposed of safely and where it will not be a danger to small children.

UNPACKING
Carefully remove the unit from its transit box and wrapping, and visually check for any signs of transit damage. If there are any signs of damage DO NOT attempt to operate the unit, call your supplier for advice. Retain the packaging for further use, or dispose of it considerately.

GENERAL
The PF400 should only be operated in the horizontal position and with the unit standing on a firm, level floor. A flexible duct can be attached to either inlet or outlet in order to transport the air over longer distances. Connection to the PF400 is done by using the quick release “Belted Cuff”, unique to the Ebac PF400 Ventilator. Connect the power cord to a suitable supply and the unit is ready for operation.

SWITCHING ON
The PF400 ON / OFF switch is located on the inside of the rear foot. To start the unit, depress the switch.
Since the PF400 a considerable high suction power, always ensure that the inlet grille is kept free of any obstruction during operation.
SWITCHING OFF
Set the ON / OFF to the OFF position. Turn off the power and disconnect.

ELECTRICAL CONNECTIONS
-WARNING-
THIS APPLIANCE MUST BE EARTHED

IMPORTANT – The wires in the mains lead are coloured in accordance with the following code:-

Blue                            Neutral
Brown                        Live
Green & Yellow        Earth

As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your own plug, proceed as follows.
The wire which is coloured Green & Yellow must be connected to the terminal marked E or by the Earth Symbol or coloured Green or Green & Yellow.
The wire which is coloured Blue must be connected to the terminal in the plug which is marked with the letter N or coloured Black.
The wire which is coloured Brown must be connected to the terminal in the plug which is marked with the letter L or coloured Red.
You must safely dispose of the non-rewireable plug once it has been removed from the flexible cord. It is dangerous to attempt to insert the plug into any electrical socket.

CHANGING THE FUSE
Only 13amp fuses that are STA approved to BS1362 should be used.

NON REWIREABLE PLUGS
The fuse cover must be refitted after replacement of the fuse.

SERVICE
This machine should be serviced by qualified Ebac personnel or other persons having technical competence.

SPARES
Full spare parts listings are available upon request by contacting one of the Ebac Service Centres listed in this manual.

SAFETY

-WARNING-
THE FAN IS NOT FLAMEPROOF

  • DO NOT use this unit in an environment for the extraction of FLAMMABLE FUMES.
  • DO NOT use the unit if the cabinet or power cord is damaged.
  • DO NOT insert objects into any the grille on the machine.
  • DO NOT cover or obstruct airflow from the grilles.
  • DO NOT operate the unit with the covers removed.
  • DO NOT attempt any repairs should the unit fail to operate.
  • DO NOT stand on the unit.
  • DO check the plug on the equipment matches the supply.
  • DO use this unit for the purpose for which it was designed.
  • DO ensure the power cord and supply is earthed correctly.
  • DO use a residual current device “RCD” where possible.

TECHNICAL SPECIFICATION

| 1092630| 1092640| 1092640EU
---|---|---|---
Height:| 355 mm| 355 mm| 355 mm
Width:| 363 mm| 363 mm| 363 mm
Depth:| 350 mm| 350 mm| 350 mm
Weight:| 19 Kg| 19 Kg| 19 Kg
Power:| 550 W| 550 W| 550 W
Voltage:| 110 V| 230 V| 230 V
Airflow:| 3500 m3/hr| 3500 m3/hr| 3500 m3/hr
Static Pressure:| 40 mm/wg| 40 mm/wg| 40 mm/wg
Fan Blade Diameter:| 280 mm| 280 mm| 280 mm
Noise Level:| >70 Dba| >70 Dba| >70 Dba
Finish:| Epoxy Coated Zintec Steel
Mobility:| Light Construction – Static Use Only

Manufactured in the United Kingdom
Spare parts available online
www.EIPLDIRECT.com

WARNINGS
This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person in order to avoid hazard.

EBAC SERVICE CENTRES

Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland
County Durham
DL14 9AD
Tel: +44 (0) 1388 664400 Fax: +44 (0) 1388 662590
www.eipl.co.uk
sales@eipl.co.uk

Ebac Industrial Products Ltd. Gartenfelder Str. 29-37 Gebäude 35
D-13599, Berlin
Germany
Tel: +49 3043 557241
Fax: +49 3043 557240
www.eip-ltd.de
sales@eip-ltd.de

Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575
USA
Tel: +01 757 873 6800 Fax: +01 757 873 3632
www.ebacusa.com sales@ebacusa.com

Charmex S.A. Venezuela, 31-35 08019 Barcelona Espana
Tel: +34 93 203 4406 Fax: +34 93 266 4687

CONTACTING EBAC CUSTOMER SERVICES
If you have any further queries please contact the Ebac Customer Services Department on 01388 664400 and have the following information at hand:-

  • Part Number and Serial Number of the machine (located on the rating plate at the front of the machine)
  • Full name and address where your machine was purchased.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals