INTRODUCTION
This user manual tells you how to operate the PF400. Please read thoroughly before operating the unit. If you have any questions please contact our Customer Services Department at the address shown at the back of this manual.
IMPORTANT
Your PF400 is packed in a plastic wrapping – please ensure that it is disposed
of safely and where it will not be a danger to small children.
UNPACKING
Carefully remove the unit from its transit box and wrapping, and visually
check for any signs of transit damage. If there are any signs of damage DO NOT
attempt to operate the unit, call your supplier for advice. Retain the
packaging for further use, or dispose of it considerately.
GENERAL
The PF400 should only be operated in the horizontal position and with the unit
standing on a firm, level floor. A flexible duct can be attached to either
inlet or outlet in order to transport the air over longer distances.
Connection to the PF400 is done by using the quick release “Belted Cuff”,
unique to the Ebac PF400 Ventilator. Connect the power cord to a suitable
supply and the unit is ready for operation.
SWITCHING ON
The PF400 ON / OFF switch is located on the inside of the rear foot. To start
the unit, depress the switch.
Since the PF400 a considerable high suction power, always ensure that the
inlet grille is kept free of any obstruction during operation.
SWITCHING OFF
Set the ON / OFF to the OFF position. Turn off the power and disconnect.
ELECTRICAL CONNECTIONS
-WARNING-
THIS APPLIANCE MUST BE EARTHED
IMPORTANT – The wires in the mains lead are coloured in accordance with the following code:-
Blue Neutral
Brown Live
Green & Yellow Earth
As the colours of the wires in the mains lead of this appliance may not
correspond with the coloured markings identifying the terminals in your own
plug, proceed as follows.
The wire which is coloured Green & Yellow must be connected to the terminal
marked E or by the Earth Symbol or coloured Green or Green & Yellow.
The wire which is coloured Blue must be connected to the terminal in the plug
which is marked with the letter N or coloured Black.
The wire which is coloured Brown must be connected to the terminal in the plug
which is marked with the letter L or coloured Red.
You must safely dispose of the non-rewireable plug once it has been removed
from the flexible cord. It is dangerous to attempt to insert the plug into any
electrical socket.
CHANGING THE FUSE
Only 13amp fuses that are STA approved to BS1362 should be used.
NON REWIREABLE PLUGS
The fuse cover must be refitted after replacement of the fuse.
SERVICE
This machine should be serviced by qualified Ebac personnel or other persons
having technical competence.
SPARES
Full spare parts listings are available upon request by contacting one of the
Ebac Service Centres listed in this manual.
SAFETY
-WARNING-
THE FAN IS NOT FLAMEPROOF
- DO NOT use this unit in an environment for the extraction of FLAMMABLE FUMES.
- DO NOT use the unit if the cabinet or power cord is damaged.
- DO NOT insert objects into any the grille on the machine.
- DO NOT cover or obstruct airflow from the grilles.
- DO NOT operate the unit with the covers removed.
- DO NOT attempt any repairs should the unit fail to operate.
- DO NOT stand on the unit.
- DO check the plug on the equipment matches the supply.
- DO use this unit for the purpose for which it was designed.
- DO ensure the power cord and supply is earthed correctly.
- DO use a residual current device “RCD” where possible.
TECHNICAL SPECIFICATION
| 1092630| 1092640| 1092640EU
---|---|---|---
Height:| 355 mm| 355 mm| 355 mm
Width:| 363 mm| 363 mm| 363 mm
Depth:| 350 mm| 350 mm| 350 mm
Weight:| 19 Kg| 19 Kg| 19 Kg
Power:| 550 W| 550 W| 550 W
Voltage:| 110 V| 230 V| 230 V
Airflow:| 3500 m3/hr| 3500 m3/hr| 3500 m3/hr
Static Pressure:| 40 mm/wg| 40 mm/wg| 40 mm/wg
Fan Blade Diameter:| 280 mm| 280 mm| 280 mm
Noise Level:| >70 Dba| >70 Dba| >70 Dba
Finish:| Epoxy Coated Zintec Steel
Mobility:| Light Construction – Static Use Only
Manufactured in the United Kingdom
Spare parts available online
www.EIPLDIRECT.com
WARNINGS
This appliance can be used by children from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of
the application in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without
supervision.
If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified person in order to avoid hazard.
EBAC SERVICE CENTRES
Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland
County Durham
DL14 9AD
Tel: +44 (0) 1388 664400 Fax: +44 (0) 1388 662590
www.eipl.co.uk
sales@eipl.co.uk
Ebac Industrial Products Ltd. Gartenfelder Str. 29-37 Gebäude 35
D-13599, Berlin
Germany
Tel: +49 3043 557241
Fax: +49 3043 557240
www.eip-ltd.de
sales@eip-ltd.de
Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News
Virginia, 23606-2575
USA
Tel: +01 757 873 6800 Fax: +01 757 873 3632
www.ebacusa.com
sales@ebacusa.com
Charmex S.A. Venezuela, 31-35 08019 Barcelona Espana
Tel: +34 93 203 4406 Fax: +34 93 266 4687
CONTACTING EBAC CUSTOMER SERVICES
If you have any further queries please contact the Ebac Customer Services
Department on 01388 664400 and have the following information at hand:-
- Part Number and Serial Number of the machine (located on the rating plate at the front of the machine)
- Full name and address where your machine was purchased.
References
- EIP Group - Industrial Dehumidifiers
- EIP Group - Industrial Dehumidifiers
- EIPL - Industrial Dehumidifiers
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>