Efforts have been made to ensure the accuracy and reliability of the data contained in this publication; however, CityGrow Energy Systems Limited makes no representation, warranty, or guarantee in connection with this publication and hereby expressly disclaims any liability or responsibility for loss or damage resulting from its use or from the use of any product or methodology described herein; for any violation of any federal, state, or municipal regulation with which this publication may conflict; or for the infringement of any patent from the use of this publication. Nothing contained in this publication should be viewed as an endorsement by CityGrow Energy Systems Limited of any particular manufacturer’s products.

CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE

PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL

**** The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.

IMPORTANT SAFETY INSTRUCTIONS

READ BEFORE OPERATING EQUIPMENT

This product was designed and manufactured to meet strict quality and safety standards.

There are, however, some installation and operation precautions which you should be particularly aware of

  1. Read these instructions.
  2. Keep these instructions.
  3. Heed all warnings.
  4. Follow all instructions.
  5. Do not use this apparatus near water.
  6. Clean only with dry cloth.
  7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
  8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.
  9. Do not defeat the safety purpose of the polarized or grounding-type plug. If the provided plug does not fit into your outlet, consult an electrician for replacement of the outlet.
  10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
  11. Only use attachments/accessories specified by the manufacturer.
  12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
  13. Unplug this apparatus during lightning storms.
  14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

Introduction

Thank you for choosing CityGrow’s product. CG100H Series is highly-functional, user-friendly and installation-friendly. It is specially designed for scene control. User can program the plate button for performing group control on different devices, including lights, curtains, airconditioners, AV equipment and others

Description

  1. ZigBee wireless remote control.
  2. Based on IEEE 802.15.4.
  3. 2.4GHz radio frequency.
  4. CG100HTH – thermostat with inbuilt temperature sensor, operate with CG401S5-FCU Fan Coil Unit Controller.
  5. CG100HTHV1 – thermostat without sensor, operate with CG401S5-FCU Fan Coil Unit Controller which inbuilt with temperature sensor.
  6. CG100HTH-IR – thermostat without sensor, operate with CG102IR-AC ZigBee IR Transmitter to control air-conditioner.
  7. CG100HHB – doorbell.
  8. CG100Hx-MD – scene control.
  9. LED indicator for status indication.
  10. Plate button can perform two-way function.
  11. Plate button can perform scene control function.
  12. Powered by CG101AD external DC6V Mini Power Supply. (Purchase separately)
  13. Button graphics can be customized.
  14. With CG102BS-R Base Station, all devices support iOS/Android App control.
  15. Easy to install.

Understanding the product – CG100H4-MD

Understanding the product – CG100H4-MD

Understanding the product – CG100H4-MD

Understanding the product – CG100H4-MD

Understanding the product – CG100H4-MD

Understanding the product – CG100H8-MD

Understanding the product – CG100H8-MD Understanding the product –
CG100H8-MD Understanding the product –
CG100H8-MD Understanding the product –
CG100H8-MD

Understanding the product – CG100HTH/CG100HTHV1

Understanding the product – CG100HTH/CG100HTHV1 Understanding the product –
CG100HTH/CG100HTHV1 Understanding the product –
CG100HTH/CG100HTHV1 Understanding the product –
CG100HTH/CG100HTHV1

Understanding of product – CG100HHB

Understanding of product – CG100HHB

Dimensions

CG100H4-MD, CG100HTH, CG100HHB

CG100H8-MD
Dimensions

Wiring

Wiring

Wiring

Before getting started

WARNING! It must be installed by a qualified electrician in accordance to all applicable regulations and building codes. Improper wiring can result in personal injury or damage to control units or other equipment. Always turn off circuit breaker or remove main fuse from power line before doing any work. To avoid overheating and possible damage to equipment.
WARNING! Do not operate when any lamps removed or burned out; replace any burned out lamps immediately; use only transformers that incorporate thermal protection or fused primary windings. ! This product is designed for residential and commercial use, for indoor use only.
WARNING! Install in accordance to all national and local electrical codes.
IMPORTANT! CityGrow® is not liable for any damage incurred with the misuse of the product.
IMPORTANT! Pre-setup can only be done by a professional technician or manufacturer agent.

Installation

Please follow the instructions to install the product.

STEP 1: IMPORTANT! Turn off main power at the main switch board.

STEP 2: Loosen the screws of the original wall switch. Remove the switch and disassemble the wiring.

STEP 3: Connect the main power cable to the Live and Neutral terminals of the CG101AD Mini Power Supply. Then connect the DC output wires of the CG101AD to the DC input of the CG100H Series product.

For CG100H4-MD and CG100HTHInstallation

For CG100HHB
Installation

For CG100H8-MD
Installation

STEP 4: Fasten the screws of all terminals and check that the wires are properly secured. Retrofit the switch into the standard switch box and mount it on the wall by fastening the two screws at the rear of the switch box.
Installation

STEP 5: Power up the main switch board, the LED indicators on CG100H Series product should be lightened up. Program the CG100H Series product by using HomeNet Planner 2 software to setup the function of the buttons on the control plate.

Notes: Use Standard UK BS4662 wall box for installation (minimum 35m depth). It is recommended to embed the wall box with maximum depth fixed inside the wall for more sufficient installation space, preferably with 50mm depth for installation.

Operation instruction

CG100H4-MD 8-Scene Control Plate
  1. Number 1 to 8 are buttons location.

  2. Frame
    CONTROL PLATE COVER

  3. 4 pcs of Lock for fixing the main unit onto the wall bracket.

  4. Reset button

  5. Program port
    MAIN UNIT

Button number 1 to 8 can be programmed individually as power ON/OFF button, or Dim Up/Dim Down button or scene control button. The programming procedures should be done with HomeNET Planner 2 Software.

Press the button to activate the programmed function.

The backlit of the control plate will be lightened up.

  • BRIGHT LED indicates that the programmed function is ON.
  • DIMMED LED indicates that the programmed function is OFF.
CG100H8-MD 8-Scene Twin Control Plate
  1. Number 1 to 16 are buttons location.

  2. Frame
    CONTROL PLATE COVER

  3. Reset button

  4. Program port

  5. 8 pcs of Lock for fixing the main unit onto the wall bracket.
    MAIN UNIT

Button number 1 to 16 can be programmed individually as power ON/OFF button, or Dim Up/Dim Down button or scene control button. The programming procedures should be done with HomeNET Planner 2 Software.

Press the button to activate the programmed function.

The backlit of the control plate will be lightened up.

  • BRIGHT LED indicates that the programmed function is ON.
  • DIMMED LED indicates that the programmed function is OFF.
CG100HHB Doorbell Switch
  1. Doorbell button.

  2. Frame.

  3. MUR Make Up Room Indicator (For Hotel Only)

  4. DND Do Not Disturb (For Hotel Only)
    COVER PLATE

  5. 4 pcs Locks to fix the main unit onto the wall bracket.

  6. Reset button

  7. 7. Program port
    MAIN UNIT

For Hotel Use, this product will be pre-programmed.

When the Doorbell button is pressed for 1 second, the dry contact output will drive the doorbell to ring for 1 second.

For Home Use, this product can be programmed with control function and the programming procedures should be done with HomeNET Planner 2 Software.

Press the button to activate the programmed function.

The backlit of the control plate will be lightened up.

  • BRIGHT LED indicates that the programmed function is ON.
  • DIMMED LED indicates that the programmed function is OFF.
CG100HTH/CG100HTHV1 Thermostat
  1. Display window showing the temperate readings and settings.

  2. Frame

  3. Press Up/Down to control the fan speed at High/Mid/Low level.

  4. Press Up/Down to preset the room temperature.

  5. Power ON/OFF control of the airconditioner.
    CONTROL PLATE COVER

  6. 4 pcs of Lock for fixing the main unit onto the wall bracket.

  7. Reset button

  8. Program port
    MAIN UNIT

Display Window:
When no button is being pressed, the display window will show the set temperature.
Temp Up/Down button:
Press Up or Down to change the preset temperature.
Fan Speed Up/Down button:
Press Fan Speed Up/Down button will change the fan speed of the A/C. The fan speed will change in High -> Mid -> Low order. The display window will show the settings.
On/Off button:
Press the On/Off button will switch the A/C On or Off. When A/C is off, the display window will be off.

Adding the product to your Home Wireless ZigBee Network

STEP 1
Open the front cover, you will see a 5-pin connector.
STEP 2
Plug the CG101UT5 cable into the 5- pin connector of the product, and then plug the other end of the CG101UT5 cable into the mini USB end of the CG101UTC cable.
STEP 3
Plug the CG101UTC cable into the USB port of a PC which has been installed with CityGrow’s “HomeNET Planner 2” Software.
STEP 4
Refer to the user manual of “HomeNET Planner 2” Software to program and set the address of the product.

Specification

| CG100H4-MD| CG100H8-MD| CG100HTH CG100HTHV1

CG100HTH-IR

| CG100HHB
---|---|---|---|---
Description| ****

8-Scene Control Plate

| 8-Scene Twin Control Plate| Thermostat| ****

Doorbell Switch

Power supply| DC6V Powered by CG101AD external DC6V Mini Power Supply.
Maximum number of devices can be programmed in scene setting| 150| N/A
Features|

  1. 8 scenes control
  2. Curtain control

|

  1. High, Mid, Low, Cool, Heat control.
  2. Temperature preset.
  3. Room temperature display.

|

  1. Inbuilt contactor to drive ELV (low voltage door chime.
  2. Dry contact output
  3. for connection to door chime.

Remarks:|

  1. When “Up” button has been programmed as dimming up function, the “Down” button cannot be programmed with scene function.
  2. Each product can be programmed and control up to 150 devices.

|

  1. CG100HTH with inbuilt temperature sensor.
  2. CG100HTHV1 & CG100HTH-IR without temperature sensor.

|

  1. For hotel use.
  2.  DND and MUR.

Minimum dimming level setting| Support| N/A
Memory dim function| Support| N/A
LED Backlit| Support
Two-way control function| Support
Control communications| ZigBee, IEEE 802.15.4
Radio frequency| 2.4 GHz, 15 channel
Remote control distance

(line of sight)

| 100M
Operational temperature| 0°C to 40°C
Humidity| 5% to 95% non-condensing
Storage| -20°C to 70°C
Dimension

L X W x D (mm)

| 85x85x28