S0500-230V-EU Labnet GyroMini Nutating Mixer
Specifications
-
Motion: 3-dimensional rocking motion
-
Speed: S0500 – 120V~, 50/60 Hz, 0.03A, 3.6W; S0500-230V –
230V~, 50/60 Hz, 0.017A, 4W -
Platform Tilt Angle: N/A
-
Platform Dimensions: N/A
-
Mixer Dimensions (L x W x H): N/A
-
Mixer Weight: N/A
-
Platform Load Capacity: N/A
-
Platform Capacity without Stacking: N/A
-
Temperature Range: N/A
-
Electrical: IP21
-
Protection Class: N/A
Product Usage Instructions:
Installation:
Plug the unit into a properly grounded outlet of the appropriate voltage as
shown on the unit’s data plate label.
FAQ:
Q: Can I stack tubes on the platform?
A: Tubes can be stacked on the platform, but ensure they are secured with
rubber bands or bungie cords to prevent accidents.
introduction
The Labnet GyroMini™ Nutating Mixer is a 3-dimensional mixer typically used for maintaining the uniform suspension of blood components in blood collection tubes without foaming. This Nutating Mixer is also ideal for mixing large strands of DNA into solution in microcentrifuge tubes or mixing blood into a buffer in large centrifuge tubes. The Nutating Mixer achieves its 3-dimensional mixing by combining the rotating motion of an orbital shaker with the rocking motion of a platform rocker.
Symbols and Conventions
The electrical warning indicates the presence of a potential hazard which
could result in electrical shock.
CAUTION: This symbol refers you to important operating and maintenance
(servicing) instructions within this Instruction Manual. Failure to heed this
information may present a risk of damage or injury to persons or equipment.
This symbol identifies a Protective Earth (PE) terminal, which is provided for
connection of the supply system’s protective earth (green or green/yellow)
conductor.
Technical Specifications
The Labnet GyroMini Nutating Mixer is designed to be safe at least when operated under the following conditions:
- Indoor use only
- Altitude up to 2,000 meters
- Pollution degree 2
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. The equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the user manual, may cause harmful interference to radio communications. Operation of equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference.
CAUTION: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme à la norme NMB-001 du Canada.
Installation
The Labnet GyroMini™ Nutating Mixer can be used on a bench, in a cold room, or
in an incubator up to 40°C. Place the unit on a flat stable surface and be
sure to leave sufficient room around the unit to allow the platform to run
freely. A minimum of 4 inches (10 cm) clearance on all sides of the mixer is
advised.
Plug the unit into a properly grounded outlet of the appropriate voltage as
shown on the unit’s data plate label.
Operating Instructions
Tubes may be placed directly on to the dimpled mat. The dimple pattern is configured to allow blood tubes and centrifuge tubes to be securely placed on the mat without additional strapping in most cases. If tubes are to be stacked, they should be secured with rubber bands or bungie cords. Holes in the corners of the platform edges are provided for this purpose.
NOTE: Always load the platform in a uniform and balanced fashion.
Use the power switch to turn the unit on. The direction of rotation in which
the unit starts is random and does not affect mixing.
If desired, the rotational direction can be reversed by holding the unit’s
base and very briefly touching the rotating platform on the bottom at one
corner. This technique can also be used to select the quietest direction of
rotation.
Cleaning and Maintenance
NOTE: Always disconnect the cord from the power source before maintaining or
servicing.
The Labnet GyroMini Nutating Mixer requires no maintenance other than
occasional cleaning with a damp cloth with mild detergent. The dimpled mat may
be washed with soap and water. Do not immerse the unit in water or spill
liquids over the unit. Be sure the unit is dry before reconnecting to power.
Limited Warranty
-
Corning Incorporated (Corning) warrants that this product will be free from defects in material and workmanship for a period of
one (1) year from date of purchase. CORNING DISCLAIMS ALL OTHER WARRANTIES WHETHER EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. Corning’s sole obligation shall be to repair or replace, at its option, any product or part thereof that proves defective in material or workmanship within the warranty period, provided the purchaser notifies Corning of any such defect. Corning is not liable for any incidental or consequential damages, commercial loss or any other damages from the use of this product. -
This warranty is valid only if the product is used for its intended purpose and within the guidelines specified in the supplied instruction manual. This warranty does not cover damage caused by accident, neglect, misuse, improper service, natural forces or other causes not arising from defects in original material or workmanship.
-
This warranty does not cover motor brushes, fuses, light bulbs, batteries or damage to paint or finish. Claims for transit damage should be filed with the transportation carrier.
-
n the event this product fails within the specified period of time because of a defect in material or workmanship, contact Corning Customer Service at: USA/Canada 1.800.492.1110, outside the U.S. +1.978.442.2200, visit www.corning.com/lifesciences, or contact your local support office.
Corning’s Customer Service team will help arrange local service where available or coordinate a return authorization number and shipping instructions. Products received without proper authorization will be returned. All items returned for service should be sent postage prepaid in the original packaging or other suitable carton, padded to avoid damage. Corning will not be responsible for damage incurred by improper packaging. Corning may elect for onsite service for larger equipment. -
Some states do not allow limitation on the length of implied warranties or the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights. You may have other rights which vary from state to state.
-
No individual may accept for, or on behalf of Corning, any other obligation of liability, or extend the period of this warranty.
For your reference, make a note of the serial and model number, date of purchase, and supplier here.
- Serial No. __
- Model No. _____
- Date Purchased ___
- Supplier _____
Equipment Disposal
According to Directive 2012/19/EU of the European Parliament and of the
Council of 4 July 2012 on waste electrical and electronic equipment (WEEE),
this product is marked with the crossed-out wheeled bin and must not be
disposed of with domestic waste.
Consequently, the buyer shall follow the instructions for reuse and recycling
of waste electronic and electrical equipment (WEEE) provided with the products
and available at www.corning.com/weee
To request certificates, please contact us at
www.labnetlink.com.
Warranty/Disclaimer: Unless otherwise specified, all products are for research
use or general laboratory use only. Not intended for use in diagnostic or
therapeutic procedures. Not for use in humans. These products are not intended
to mitigate the presence of microorganisms on surfaces or in the environment,
where such organisms can be deleterious to humans or the environment. Corning
Life Sciences makes no claims regarding the performance of these products for
clinical or diagnostic applications. For a listing of US medical devices,
regulatory classifications or specific information on claims, visit
www.corning.com/resources.
Corning’s products are not specifically designed and tested for diagnostic
testing. Many Corning products, though not specific for diagnostic testing,
can be used in the workflow and preparation of the test at the customers
discretion. Customers may use these products to support their claims. We
cannot make any claims or statements that our products are approved for
diagnostic testing either directly or indirectly. The customer is responsible
for any testing, validation, and/or regulatory submissions that may be
required to support the safety and efficacy of their intended application.
Corning Incorporated
Life Sciences
www.corning.com/lifesciences
NORTH AMERICA t 800.492.1110 t 978.442.2200
ASIA/PACIFIC
Australia/New Zealand t 61 427286832
Chinese Mainland t 86 21 3338 4338
India t 91 124 4604000
Japan t 81 3-3586 1996
Korea t 82 2-796-9500
Singapore
65 6572-9740
Taiwan
886 2-2716-0338
EUROPE
CSEurope@corning.com
LATIN AMERICA
grupoLA@corning.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>