HTRC P20 20Amp 12V-24V Battery Charger and Maintainer User Manual
- June 6, 2024
- HTRC
Table of Contents
HTRC P20 20Amp 12V-24V Battery Charger and Maintainer
Arsalan khan post
IMPORTANT INFORMATION
Technical Specifications
Model | P20/20AMP/N20 |
---|---|
AC Input Voltage: | 100-240V~50/60Hz |
Applicable battery type: | Lithium, LiFePO4, Lead-acid (AGM, GEL, EFB,MF, |
FLOODED, VRLA, SLA, WET, etc.)
Applicable battery voltage:| 12V,24V
Charging Current:| Max 20A(12V),Max 10A(24V)
Minimum Start Volt:| 2V
Input Power with Load:| Max 280W
Net weight:| 470g
Dimension:| 1589050mm
Interface description
Charge current switch. 3 levels are optional: 5A(12V)/3A(24V), 10A(12V)/5A(24V), 20A(12V)/10A(24V).
For charging 12V or 24V Lithium batteries, for batteries used on Battery Management Systems(BMS) only.
For ordinary lead-acid batteries/maintenance-free batteries including AGM, GEL, SLA, WET, DEEP CYCLE, EFB, Calcium, etc. For charging 12V or 24V LiFePO4 batteries.
For activation or maintenance of weak, old and idle batteries.
Can not repair severely damaged batteries. Only for lead-acid batteries.
Used to select a mode
Auto-Memory :The charger has a memory function and will automatically select the last mode
How to charge the battery?
- Connect the charger to the AC power.
AC:100-240V 50~60Hz
-
Adjust and select the appropriate charging current gear.
-
Select the corresponding mode according to the battery type.
-
Connect the charger and battery. (The charger automatically recognizes the battery voltage and selects 12V or 24V.)
Note :
- Don not charge for the lithium battery without battery protection board(BMS).
- Charge batteries with a capacity of less than 20AH with the minimum current.
Estimated Charging Time For Different Battery Capacities.
**** Battery Capacity (Ah) | Charging Time(H) |
---|---|
**** 12V 5A | **** 12V 10A |
24V 10A
50(Ah)| 6.5 H| 3.1 H| /| 10 H| 6.5 H|
3.1 H
120(Ah)| 15 H| 7.5 H| 4.2H| 25 H| 15 H|
7.5 H
150(Ah)| 19 H| 9.5 H| 5.0 H| 31.5 H| 19 H| 9.5 H
200(Ah)| 25 H| 12.5 H| 6.5 H| /| 25 H|
12.5 H
400(Ah)| /| 25 H| 12.5 H| /| /| 25 H
1000(Ah)| /| /| 38 H| /| /| 76 H
The estimated charging time is for reference only, please refer to the actual
time.
Features
- Supports Lithium,Lead-acid(AGM,GEL,SLA,Flooded,WET,EFB,etc.) and LiFePo4 battery.
- Fully automatic microprocessor control. 9-stage charging program provides the best and most efficient battery charging.
- Charging voltage automatically adapts to temperature to prevent over-or under-charging.
- With repair function to repair old, weak and idle batteries.
- With overcharge protection, reverse polarity protection, short circuit protection, sparks free contact, etc.
- With LCD screen showing voltage, current, battery power,temperature etc.
- Charge current can be selected.
- The charger has auto-memory function and will return to the last mode when connected.
Screen Icon Description
Charge Current
Battery Capacity
Battery Voltage
Battery Real-time Voltage
Standby
Repair process ended
Low Voltage
Battery Full
Winter Mode
Summer Mode
Charging inside Temperature
Charge Quantity
Repair
MoRepair Mode. An advanced battery recovery mode for repairing and storing
old, idle, damaged, stratified and sulfated batteries. The maximum repair time
is 24 hours. Only for lead-acid batteries. Can not repair badly damaged
batteries.
Wrong polarity, please change the connection of the clamps.
Defect battery, please let the battery be checked by a mechanic and if
necessary change the battery.
Bad connection, please check the connection between the charger and the
battery.
stage charging process optimizing battery power precisely and gently.
- Battery desulfation
- Soft start charging
- Bulk charging
- Absorption charging
- Trickle charge
- Battery test
- Recondition charging
- Float & maintenance charging
- Small current to maintain charging
WARNING
- Don not charge for the lithium battery without battery protection board(BMS).
- Charge the battery below 20AH with the minimum current.
- The charger is designed for 12V and 24V Lithium,Lead-acid, LiFePO4 batteries.
- Check battery specifications before using.
- Provide ventilation to prevent flames and sparks.
- Do not expose charger to the sun, or under high temperature environment.
- Battery acid is corrosive. Rinse immediately with water if acid comes into contact with skin or eyes.
- Do not charge a frozen or damaged battery.
- Do not charge non-rechargeable batteries.
- Do not place the charger on the battery while charging.
- Be extra cautious to reduce risk of dropping a metal tool on the battery. It might spark or short-circuit battery or other electrical part that may cause explosion.
- When working with a lead-acid battery, remove personal metalitems such as rings, bracelets, necklaces, watch…
- Do not smoke or allow a spark or flame while charging.
- In order to reduce risk of electric shock, unplug charger from AC outlet before doing any maintenance or cleaning .
- Not intended for children and anyone unable to follow the user manual.
Read User Manual Online (PDF format)