ZKTECO X7 Access Control System User Manual
- June 6, 2024
- ZKTECO
Table of Contents
X7 Access Control System
User Manual
Equipment Installation
Wall-mount installation
Structure and Function
‘Access Control System Function:
- If a registered user is verified, the device will send a signal to unlock the door.
- The door sensor will detect whether the door is open or not. If the door is unexpectedly opened or improperly closed, the alarm will be triggered.
- If the device is dismantled, it will send an alarm signal.
- It supports the Exit Button; it is convenient to open the door inside.
- It supports Door Bell; visitors could call by the doorbell.
Lock Connection
Warning: No operation when power on!
- The system supports NO LOCK and NC LOCK For example the NO LOCK (normally open at power on) is connected with the NO terminal, and the NC LOCK is connected with the NC terminal.
- When the Electrical Lock is connected to the Access Control System, you need to parallel one FR107 diode (equipped in the package) to prevent the self-inductance EMF affect the system, do not reverse the polarities. Share power with the lock:
Connected with Other Parts Connect with Power
Instructions
Step 1: Power on after the device is completely installed on the wall.
Step 2: Change the administrator password, and configure access control
parameters, including unlocking duration, authentication mode, concealed mode,
door sensor mode, alarm, etc.
Step 3: Register users’ cards, fingerprints or eight passwords.
Operation Instructions
1. User Management
1.1 Administrator Operations
To ensure the data security of the device, you can operate the device only
after the administrator password is authenticated.
Administrator Authentication
Note: The initial administrator password is 1234. You are advised to
change the initial password at the beginning.
Change Administrator Password
Open the Door by Entering the Administrator Password
Note: This function can be used to open the door.
Administrator Password Is Forgotten?
If the administrator password is forgotten, please dismantle the device and
wait 30 seconds when there is a short beep, then press the Tamper Switch three
times to reset to the initial administrator password, note this operation must
be done within 30 seconds. Note: The initial administrator password is 1234.
1.2 Add Users
Register the fingerprint or card of a user or register cards in batches.
Add Users
Note:
- Press [#] to confirm after the user ID is entered.
- If the user ID is not available, the ID number increases automatically. It continues to register a new one once a user is successfully registered.
- The registration fails if the user ID, fingerprint, or card has been registered (the Indicator turns red and makes three short beeps). When the Indicator turns green, you can register the user again. If you fail in swiping the card, pressing fingerprint, or entering your user ID three times, the device will enter the standby state.
Register Cards in Batches (optional functions)
©Note:
- In the process of entering the total number of cards, three-digit numbers are automatically verified. For numbers with less than three digits, press (#1 to confirm. Press [`] to reenter the total number of cards.
- You must clear all the registered users before registering cards in batches. IDs of to-be-registered cards must be consecutive numbers.
1.3 Register Eight Passwords for Opening the Door
This device supports 8 passwords, each password has a Group ID ranging from 1-8. The default password value is 0 for all groups, which means passwords are disabled. You can modify the passwords under 8 groups to open the door.
Note: If a password is successfully changed, enter the Group ID to change the
next one.
1.4 User Authentication Card / Fingerprint / Password Authentication
after the device is powered on, it enters the authentication state for users
to unlock the door.
Note: Press [#] after entering a password for authentication. The door
opens if the entered password is identical with one of the eight passwords for
opening the door. The initial eight passwords for opening the door are empty.
1.5 Delete Users
Delete a user whose fingerprint or card is registered, or delete all users.
Delete a User Note:
- You can swipe the card, press fingerprint or input a user ID to delete a user. Five digits user ID is automatically verified, if the user ID is less than five digits, press [#] to confirm.
- The device automatically enters the process of deleting the next user when a user is deleted, or press M to exit.
Delete All Users
One Note: Press [9] for automatic confirmation. Other values are considered
invalid. If an invalid value is entered, the device indicator turns red, and
the device makes a long beep and exits the process.
Access Control Management
2.1 Configure Unlocking Duration
:2 Note Press [10] for automatic confirmation. For values with less than 10,
press [#] to confirm. Values greater than 10 are considered invalid.
2.2 Configure Authentication Mode
2.3 Configure Concealed Mode
If the Concealed mode is enabled, the indicator is off.
Note: An indicator blinks to indicate the status of this function when
users are authenticating their cards or fingerprints or passwords.
2.4 Configure Door Sensor Mode
The door sensor has three modes:
- NONE: The door sensor is disabled.
- NO (Normally Open): The door sensor will send an alarm signal if it detects the door is closed.
- NC (Normally Closed) : The door sensor will send an alarm signal if it detects the door is open.
Note: The door sensor mode configured here is used as the basis for the
door sensor alarm.
2.5 Configure Alarm
Note: If an alarm is triggered, the alarm can be terminated of ter the
user is authenticated.
Configure Alarm setting
The alarm switch is turned on by default. When it’s disabled, the Error
Operation-Triggered Alarm, Tamper Alarm, the Alarm Delay for the Door Status
Sensor will be disabled.
Configure Error Operation-Triggered
Alarm If this function is enabled, alarms will be generated if the
administrator fails the authentication upon three attempts; the administrator
authentication is not allowed within 20 seconds after an alarm is generated.
Configure Tamper Alarm
If this function is enabled, alarms will be generated when the device is
dismantled from the wall. Configure whether to enable the disassembly alarm.
Configure Alarm Delay for the Door Status Sensor DSM. Delay (Door Sensor
Delay):
It is to configure the time how long would the door sensor to check the door
status.
Note:
- Three-digit values are automatically verified. For values with less than three digits, press [ti] to confirm. Values greater than 254 are considered invalid.
- When an alarm is triggered, the device interior alarm will be triggered first, then 30 seconds later, the device exterior alarm equipment will be triggered.
ZK Building, Wuhe Road, Gangtou, Bantian, Buji Town,
Longgang District, Shenzhen China 518129