ZKTECO TS 1000-2000 Pro series Tripod Turnstile Installation Guide
- June 6, 2024
- ZKTECO
Table of Contents
TS 1000-2000 Pro series Tripod Turnstile
Installation Guide
Installation Guide
Applicable Models: TS 1000/2000 Pro series Tripod Turnstile
Version: 1.1
Due to regular upgrades of systems and products, ZKTeco could not guarantee
exact consistency between the actual product and the written information in
this manual.
Installation
1.1 Installation Conditions
When installing the tripod turnstile against the wall, please reserve at least
100 mm space for opening the cover. As shown in Figure 1-1.
1.2 Cabling
Power supply and communication wire suggested to deployed underground then
into the cabinet of device.
1.3 Drilling Holes
Drill holes based on the locations of the screw holes.
1.4 Fix the Device
Fix the device on the ground by 4 expansion screws. Note: The tripod
turnstile must be connected to the Ground (earth), there is a wiring interface
near the power switch.
Installation Notes
In order to keep the arm won’t be damaged during transportation. The arm wasn’t installed on the device.
- Put arm kit into the hole of the cabinet, make sure the screw holes match with the mechanism core, then tighten 3 hex screws, as shown in Figures 2-1.
- Please make sure that the power requirements are strictly met to avoid permanent damage to the unit. Input voltage: AC 100~120V/200~240V.3.
- Power on and wait for 30s for the tripod turnstile to finish the self-check program.
- . Lift the arm manually, as shown in Figures 2-2.
Figure 2-2 Note: If the arm can not be lifted, please push the arm to close to the cabinet direction first, then lift the arm manually.
Control Board Introduction
3.1 Function Description of the Turnstile Control Board
If you are using the standard device without RFID or Fingerprint reader, you
need to connect the access control system to the mainboard, please check the
content in this chapter carefully. The turnstile control board’s diagram is
shown in Figure3-1.
Counter
Right direction indicator
External alarm & drop arm
Proximity sensor signal input
Left solenoid| Counter
Passing indicator
RS485 port
24V DC input
Drop arm solenoid| Left direction indicator
Opening signal input
12V DC output
Right solenoid
---|---|---
Figure3-1 Note: The third-party access control system lock relay trigger time
should be 1 second or less than 1 second.
3.2 Connection Diagram of the Access Controller Note: The lock relay
duration of the access control device needs to be set to 1s. Forbidden using
electrically charged objects to connect to the port of Opening Signal Input,
otherwise will damage the control board.
Maintenance
Forming maintenance consciousness
The tripod turnstile needs to be maintained regularly and repaired once it is
damaged. It is recommended that warning signs be placed at conspicuous
positions for prompting passers-by to pass in a proper way and in good order.
Reasonable maintenance consciousness helps to guarantee long-term usage of the
tripod turnstile.
Regular maintenance
A cleaning and protection liquid dedicated for stainless steel is recommended
to wipe the outer shell of the equipment regularly. The tripod turnstile used
outdoors or in an environment with lots of dust must be maintained once a year
at least, for example, clean up the dust and add appropriate lubricating oil
to Disk Wheel. Note regular maintenance should be performed after powering off
the equipment, as shown in Figure4-1.
Turnstile-opening Solenoid
Troubleshooting
Symptom | Troubleshooting |
---|---|
The indicator is not lighted when the equipment is powered on. | It may be |
caused by the power supply or circuit.
Check whether the connection cable and power cable between are damaged, or the
wiring is loose.
The arms of the tripod turnstile cannot be lifted manually after the equipment
is powered on.| It may be caused by the problem of relative components or
drop-arm solenoid.
Check whether the drop-arm solenoid is operating, and check the work status of
the solenoid, as shown in Figure 4-1.
The tripod turnstile does not open after authentication.| It may be caused by
a lack of permission or a circuit problem.
1. Check whether the user has permission to open the turnstile.
2. Use a multimeter to check whether the NO and COM ports of the access
control system has a relay signal output.
3. Short-circuit the ports “Kl, GND” and “K2, GND”, if the turnstile is
successfully opened, it would be a problem of the controller.
The turnstile allows people to continue passing one-way side during use.| 1.
Check the Turnstile-opening Solenoid.
2. Check the access controller ‘Lock driving duration’, whether set to 1 s.
3. Check whether the Turnstile-opening solenoid is operating and check
whether the Turnstile-opening solenoid is stuck, as shown in Figure 4-1.
ZKTeco Industrial Park, No. 32, Industrial Road,
Tangxia Town, Dongguan, China.
Phone : +86 769 – 82109991
Fax : +86 755 – 89602394
www.zkteco.com