HJGSG Stericharger Instruction Manual
- June 6, 2024
- GSG
Table of Contents
- Product information
- Principle of sterilization
- Principle of sterilization
- Product display chart and function button introduction
- Instructions
- Security protection mode
- Voice description
- Technical parameter
- Packing list
- Reminder
- FCC Warning protection.
- Table of harmful substances and contents in products
- Product Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HJGSG Stericharger Instruction Manual
Product information
This product is a portable, easy to operate hand-held disinfection. The sterilization rate is 99.9%. The product has no radiation and is well cared for Your health.
Principle of sterilization
Apply to object surface disinfection, such as cabinet, hotel bed sheet, bath Objects such as vats, baby carriages and sofas.
Principle of sterilization
It can destroy the DNA or RNA of bacteria through the deep ultraviolet light of LED Because of the substructure, the bacteria can not replicate and reproduce to achieve the purpose of disinfection
Product display chart and function button introduction
Instructions
- Use 5v-2a adapter to fully charge the product.
- Press and hold the power key for 3 seconds, and the power key light turns blue For normal opening.
- Press and hold the general mode button for 3 seconds, and the general mode button The lamp turns blue, and after 5 seconds of beeping, the ultraviolet disinfection lamp lights up, Enter disinfection state.
- Short press the general mode button for 1 second, and the general mode key The lamp goes out, the ultraviolet disinfection lamp goes out, and exits the disinfection state.
- With the back of the product facing up, press the gravity mode button for 1 second, Gravity mode button light turns blue, beep 5 seconds later, purple The external line disinfection lamp lights up, enters the disinfection state, after 59 seconds ultraviolet Line disinfection light is off, gravity mode key light is off, back off Out of the disinfection state; in the disinfection state, press the 1 second gravity mode Key, gravity mode button light off, ultraviolet disinfection The lamp is off and out of the disinfection state.
- Press the infrared mode button for 1 second, and then press the infrared mode button The lamp turns blue, and after 5 seconds of beeping, the ultraviolet disinfection lamp lights up, Enter the disinfection state, after 59 seconds, the the ultraviolet disinfection lamp goes out, red In the disinfection state, press the infrared mode button for 1 second, and the infrared mode key light will turn off, and the ultraviolet disinfection lamp will turn off, and exit the disinfection status State.
- Press the Bluetooth key for 1 second, and the Bluetooth key light turns blue, Turn on Bluetooth mode and connect the product with related app After that, relevant operations can be carried out on the mobile phone
Security protection mode
- Gravity sensing mode: press button, gravity induction mode works Under the state, the the product will automatically exit the disinfection state after turning over
- Infrared induction mode: press button, infrared induction mode work When the human body is close to it, it will automatically exit the disinfection state.
Voice description
When the first mock exam is open and closed, the product will be “buzzing”. There is a beep
Technical parameter
- Product Name: Portable disinfectant
- Product model: Stericharer UVC
- Main material: ABS + PC
- Product size: 144 x 94 x 22.25 mm
- Body weight: 200g
- Input power: 5V — 2A
- Charging protocol: support apple, Samsung and bc1.2 interface specification
- Power supply interface: Micro USB
- Battery capacity: 5000mAh
- Filling time: less than 3 hours
- Bluetooth: ble 5.0
- UV lamp use time: about 150 minutes
- Standby power consumption: less than 1mA
- Working current: less than 2.5A
- UV wavelength: 275-285nm
- Safety protection: output over-current, overvoltage, over discharge, short-circuit protection; input under voltage, overcharge, over-current discharge protection; battery charging NTC protection.
- Battery parameters: Battery standard voltage: 3.7V Battery charging limit voltage: 4.2V Nominal capacity of battery: 5000mAh Battery energy: 9wh Battery executive standard: GB / t18287-2013
- Number of LED beads: 10
- Service life of UV lamp beads: 10000 hours
- Temperature: working temperature (0 ~ 40 ), storage temperature (- 20 ~ 55 )
Packing list
- Fuselage
- USB line
- Instruction manual x1
- Hand held handle x1
Reminder
- Please use the adapter that meets the voltage for charging, otherwise it may be damaged Bad products
- Please fully charge the product before use.
- Keep away from magnet when using.
- Please keep the product manual carefully
- In order to improve the performance of the product, there is a function of the product in Production For any changes, please refer to the goods in the packing box.
FCC Warning protection.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Any Changes or
modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment. This equipment has
been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.
Table of harmful substances and contents in products
This form is prepared according to SJ / t11364
O: It means that the content of the harmful substance in all homogeneous
materials of the component is in accordance with GB / T 26572 The limit
requirements are as follows
X: It means that the content of the harmful substance in at least one
homogeneous part of the component exceeds the provisions of GB / t26572 Limit
requirement Note: the reason why this product is marked with “X” is that there
is no alternative technology or component available at this stage
Product Warranty
Warranty details Thank you for purchasing our products, in order to let you
rest assured that the use of this product, better To protect your rights and
interests, our company will abide by the joint information production of AQSIQ
On the basis of industry department, after-sales service is implemented.
Not within the scope of services
- Has exceeded the limited service or free maintenance period
- Failure or damage caused by failure to use, maintain and keep in accordance with proper instructions The consumer takes apart the product by himself.
- It is considered that the product is defective due to factors (such as operation error, bump, improper input Voltage)
Product model:
Purchase date:
Distributor:
User name:
Contact number:
User address:
This certificate is an important basis for product after-sales service. Please keep it properly!
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>