Hydro Tab NMEA 2000 Air Unit Max (With Fx Series) Instruction Manual

June 5, 2024
Hydro Tab

Hydro Tab NMEA 2000 Air Unit Max (With Fx Series)

Disclaimer

The interceptor units are also steering equipment and it is the sole responsibility of the navigator-operator to ensure that, at any point, any problem that will alter the boat’s course, rising from the malfunction of interceptors, should be dealt with immediately by the operator. Under no circumstances, the fault of our interceptor equipment leading to any kind of accident creates liability for the manufacturer.

Trademark Notice

The hydro tab is a registered trademark of Olympic Engineering Ltd, Greece. All other trademarks, trade names, or company names referenced herein are used for identification only and are property of their respective owners.

Patent Notice

The Hydro tab products are protected by patents and industrial design patents, patents pending or design patents pending.

Declaration of conformity

This product conforms to the following Electromagnetic Compatibility (EMC) regulations and standards for use in marine environments. CE EN 60945

Technical information and Documentation

The technical information provided in this document was accurate and correct at the corresponding production time of the Hydro tab interceptors. Our operating principal for improving the manufactured product may lead to changes regarding its specifications without prior notice. Liability will not be accepted for any inaccuracy considering the product and the user manual.

Fair use statement

This manual can be printed or copied for your own use only. Copies should not be provided to third parties and manual should not be commercialized.

Product Disposal

Waste removal of this product must be according to the Waste Electrical and Electronic Equipment (WEEE) Directive.

Product Registration

Please register your product online in order for the warranty to be valid.

Air Unit Max Installation

WARNING

THE AIR UNIT MUST BE INSTALLED IN A COMPARTMENT FREE OF EXPLOSIVE OR FLAMMABLE GASES. WARNING: THE AIR UNIT MUST BE INSTALLED 20cm BELOW ANY SURFACE THAT LOCATES ABOVE IT. PLEASE ENSURE THAT THE AIR UNIT IS INSTALLED ACCORDING TO THE IP30 LIMITATIONS IP30.

Find a clear surface, place the Air Unit Max, and mark the holes with a pencil.

Hydro Tab NMEA 2000 Air Unit Max \(With Fx
Series\)-Fig3

Make holes with an Ø3 drill.

Hydro Tab NMEA 2000 Air Unit Max \(With Fx
Series\)-Fig4

Mount the Air Unit Max with the given screws.

Hydro Tab NMEA 2000 Air Unit Max \(With Fx
Series\)-Fig5

Pneumatic Connection

Technical Data & Dimensions

Hydro Tab NMEA 2000 Air Unit Max \(With Fx
Series\)-Fig7

A B C
259 mm 143 mm 459 mm

Air Unit Max DataSheet

Compressor power| 380 W
Air compressor type| Brushless, oil-free
Voltage| 24 V
Amps| 15 A
In-Line Fuse| 30 A
Max pressure| 4 bar

Direct Installation Diagram

Hydro Tab NMEA 2000 Air Unit Max \(With Fx
Series\)-Fig8

In case a new NMEA 2000 instrument is to be added, a proper NMEA Network must be built.

Installation diagram on existing NMEA Network

Hydro Tab NMEA 2000 Air Unit Max \(With Fx
Series\)-Fig9

Hydro Tab NMEA 2000 Air Unit Max \(With Fx
Series\)-Fig10

SYMBOL Part No Description
C1, C3 PNE-01202 SOLENOIDS 24V
C2, C4 PNE-01196 SOLENOIDS 24V
C5 PNE-01243 EXHAUST SOLENOID 12V
PCB PCB-00029 AIR-N2K
TIMER ELE-00698 ELECTRONIC DELAY
M PNE-01242A BRACELESS COMPRESSOR, 380W
T1 ELE-00550 THERMISTOR
NMEA 2000 ELE-00535 NMEA 5-POLE CABLE
F1 ELE-00701 CYLINDRICAL FUSE 3A

Spare Parts – Valves Assembly

Hydro Tab NMEA 2000 Air Unit Max \(With Fx
Series\)-Fig12

BOX ID| PartNo| Description| QTY.| BOX ID| PartNo| Description| QTY.
---|---|---|---|---|---|---|---
17| ELE-00535| M12, 5PIN PCB MALE CONNECTOR| 1| 31| ELE-00057| CABLE GLAND PG13.5| 1
18| ELE-00647| MINI USB PORT, FEMALE| 1| 33| PNE-00633| ELBOW MALE ADAPTOR, 1/4-8/6| 1
19| ELE-00698| RELAY TIMER| 1| 41| PNE-01242A| COMPRESSOR, BST300| 1
23| ELE-00707A| TERMINAL BLOCK 20A| 1| 42| PNE-01242B| TRANSFORMER| 1
24| GEN-00405| 4DHC CONTROLLER COVER| 1| 44| PNE-01242C| FILTER (1/2″)| 1
25| GEN-00529| AIR UNIT MAX VENTURI TUBE| 1| 67| RUB-00162| PCB RUBBER BASE| 1
26| PCB-00029| PCB FOR NMEA 2000 SYSTEM| 1| 68| RUB-00163| VENTURI RUBBER SUPPORT| 1
BOX ID| PartNo| Description| QTY.
---|---|---|---
27| PNE-00092| SAFETY VALVE, 1/8| 1
28| PNE-00101| NIPPLE, TAPER, 1/4 (M) – 1/8 (M)| 4
29| PNE-00136| FITTING, ELBOW, Φ10-1/4| 1
30| PNE-00188| REDUCER (TAPER) 1/8-1/4| 2
32| PNE-00222| ELBOW MALE ADAPTOR 6/4-1/8| 3
34| PNE-01202| FLUID CONTROL VALVE NC 1/4 Φ8 24VDC| 2
45| PNE-01243| FLUID CONTROL VALVE NC 1/4 12VDC| 1
46| PNE-01292| FITTING, ANGLE, 1/4-F12| 2
47| PNE-01298| TEE MALE ADAPTOR Φ10-1/4| 2
51| REV-00583| 20×20 FITTING ADAPTER 1/4, CUSTOM| 1
59| REV-00584| 20×20 FITTING ADAPTER 1/4, CUSTOM| 1
60| REV-00585| 25×25 FITTING ADAPTER 1/4, CUSTOM| 1
71| PNE-01196| VALVE 1/4 V24/DC| 2
72| REV-00614| VENTURI MANIFOLD| 1

Troubleshooting

Hydro Tab NMEA 2000 Air Unit Max \(With Fx
Series\)-Fig14

Warranty conditions

FW, TS, and BT Series Interceptor units (and not complete systems) are covered by a 5-year Warranty. SR Series Interceptor units (and not complete systems) are covered by a 2-year Warranty. Recoil springs, electrical/electronic parts, and devices come with a 2-year warranty. Anodes (consumables) are not included in the warranty (for BT, FW, TS Series). Hydro tab’s warranty only covers the repair or replacement of spare parts.

System selections

It is the sole responsibility of the buyer to choose the correct system and even with Hydro tab’s suggestion for a system, the overall responsibility is with the buyer.

Limited warranty

Provided that the system has been installed in accordance with the installation manual we provide, and no damage has been caused due to improper handling or practices, the Hydro tab will replace any defective parts or parts that failed due to improper manufacturing within the applicable warranty period. The hydro tab only covers the parts’ replacement. Fitting or shipping costs are not covered by the warranty. The hydro tab will select if we will repair or replace any given part. Repaired or replaced products will assume the remainder of the warranty time and under no conditions will the full time warranty be renewed.

Limited warranty periods

  • The limited warranty period is two years (2 years) from the product shipment from our premises
  • Extended limited warranty period

It is provided in case

  1. A hydro tab trim system is included as equipment of a newly purchased boat directly by from the boat-builder or his reseller.
  2. The hydro tab trim system has been purchased through a Hydro tab dealer.
  3. The extended limited warranty period is valid for three (3) years from the shipping date, provided that the customer has downloaded, completed and submitted the online registration form within one month (30) days from the purchase in the following URL.
  4. In case the dealer sells separate units of Interceptors, Air Units, and Controllers that constitute a full system that is not initially sold (as a complete system) by the Hydro tab, the dealer has the responsibility to provide the separate Serial Numbers for the Interceptors, Air Units, and Controllers and guide the end-user for the proper registration of his serial numbers for the extended warranty to be valid.
  5. The authorized dealer is responsible for the product’s service.
  6. For any services or spare parts requirements and replacements during the warranty period, the original invoice is necessary to be presented. For the replacement of any part of the system (interceptors, Air Unit, any controller, etc.) under warranty, the replaced parts must be returned to Hydro tab Marine Engineering for inspection, otherwise, the warranty is not valid. Cost of dismantling – assembly and spare parts transportation is borne by the user.
  7. The warranty does not foresee, under any circumstances, replacement of the whole Hydro tab system

What is not covered by the warranty

Damage caused by the lack of non-replacement of worn anodes (for BT, FW, TS Series). Damage caused by improper installation and use is not consistent with the manual. Damage with externally visible deformation of the product caused by misuse of the user or other external causes. Damage to any component caused during transportation, installation, or repair from non-authorized personnel. Conversions or modifications made after the initial sale.

  • Triantafillou Ltd (Hydro tab Marine Engineering) is not liable for any incidental, indirect, or consequential damages or losses, including, without limitation: travel expenses, transport, lifting and hauling, costs, loss of income, loss of time, loss of property, loss of profits, personal injury or damage of any products, different from those that the company distributes. Any further (except the above-mentioned) commitment of the intermediate dealer regarding the sale terms or servicing of Hydro tab products does not create any liability for our company.

Hydro Tab NMEA 2000 Air Unit Max \(With Fx
Series\)-Fig15

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals