FAST AG SOLUTIONS Raven RCM Rate Control Module Instruction Manual

June 5, 2024
FAST AG SOLUTIONS

FAST-AG-SOLUTIONS-Raven-Rate-Control-Module-LOGO

FAST AG SOLUTIONS Raven Rate Control Module

FAST-AG-SOLUTIONS-Raven-Rate-Control-Module-PRODUCT

RAVEN RCM SETUP

  • Enter the Profile Name:
  • FAST + Model Number
  • (Example: FAST 9518T, FAST 8313)FAST-AG-SOLUTIONS-Raven-Rate-Control-Module-FIG-1
  • Select Machine Type:
  • For Sprayers use: “Pull – behind Sprayer” For Applicators use: “Liquid Fert. Tool”
  • Enter the Application Width. Press Next.
  • Leave at “1” unless multiple ECU’s are used.
  • Press Next.FAST-AG-SOLUTIONS-Raven-Rate-Control-Module-FIG-4
  • Choose Application Mode.
  • FAST products only use “Liquid”.
  • Liquid choice selected. Press Next.
  • Enter number of sections (ball valves). FAST only uses “3-wire” valves.
  • If the sections are unequal widths, uncheck the box.FAST-AG-SOLUTIONS-Raven-Rate-Control-Module-FIG-8
  • Example setting:
  • 3 sections, 3-wire valve.
  • Box unchecked for unequal widths. Press Next
  • Enter the width of the sections.
  • For Sprayers: Enter number of tips per section x spacing = width of section.
  • The sum of the sections must equal the application width entered on (page 1).

FOR APPLICATORS

16 row, 17 coulter example, 30” spac-ing.

  • Section 1 = 5 full rate coulters = 150”. 5 x 30” = 150”
  • 1 half rate coulter = 15”.
  • 150” + 15” = 165”
  • 165” / 12” = 13.75 feet
  • Section 2 = 5 full rate coulters = 150”. 5 x 30” = 150”
  • 150” / 12” = 12.50 feet
  • Section 3 = 5 full rate coulters = 150”. 5 x 30” = 150”
  • 1 half rate coulter = 15”.
  • 150” + 15” = 165”
  • 165” / 12” = 13.75 feet

16 row, 15 coulter example, 30” spac-ing.

  • Section 1 = 4 full rate coulters = 120”. 4 x 30” = 120”
  • 1.5 rate coulter = 45”.
  • 120” + 45” = 165”
  • 165” / 12” = 13.75 feet
  • Section 2 = 5 full rate coulters = 150”. 5 x 30” = 150”
  • 150” / 12” = 12.50 feet
  • Section 3 = 4 full rate coulters = 120”. 4 x 30” = 120”
  • 1.5 rate coulter = 45”.
  • 120” + 45” = 165”
  • 165” / 12” = 13.75 feet

The sum of the sections must equal the application rate entered on page 1. Press Next.

  • Not used unless there are special require-ments.
  • Press Next.
  • Section summary per product.
  • If using a switch box, switch assignment is entered here.
  • Press Next.
  • Choose pressure sensor if installed.
  • FAST only uses 0-250 psi. Press Next.
  • FAST does not use auxiliary functions, leave unchecked.
  • Press Next.
  • Standard control valve setup.
  • If machine has a PWM pump, choose “PWM”.
  • PWM setup. Press Next.
  • If using ACE PWM pump, change the coil frequency to 122.
  • Max Pump PWM:
  • Enter a maximum PWM duty cycle percent to set the maximum desired output for a pulse width modulated (PWM) hydraulic control valve. This setting limits how far the PWM valve will open.
  • (Typically set at 100 psi. deadhead.)
  • Min Pump PWM:
  • Enter a minimum PWM duty cycle percent to set the minimum desired output (zero point or shutoff point) for a pulse width modulated (PWM) hydraulic control valve).
  • (Typically set at 20 psi. deadhead.)
  • PWM Standby:
  • Enter desired control valve PWM duty cycle percent when all sections are off. This is uti-lized when standby pressure control is not available (pressure sensor not available or direct injection is
  • installed).
  • (Typically set at within 10 psi of spray pressure.)FAST-AG-SOLUTIONS-Raven-Rate-Control-Module-FIG-21
  • Press Next.
  • Enter calibration number found on the flowmeter tag.
  • Flowmeter tag calibration number.
  • Choose “Flowmeter Pulse/Units”.
  • Flowmeter tag Pulse/Units number.
  • Flowmeter calibration number entered. Flowmeter Pulse/Units number entered. Press Next.FAST-AG-SOLUTIONS-Raven-Rate-Control-Module-FIG-26
  • FAST does not use a tank fill sensor.
  • Enter tank capacity.
  • Enter current tank level. Enter desired low tank level. Choose alarm.
  • Press Next.FAST-AG-SOLUTIONS-Raven-Rate-Control-Module-FIG-28
  • Enter the desired rates.
  • Enter the desired rate bump.
  • “Rate Bump” can be used if preferred over a predefined rate.
  • Decimal shift can be used for finer rates.
  • Example settings. Press Next.FAST-AG-SOLUTIONS-Raven-Rate-Control-Module-FIG-31
    NOTE: This setting will vary based on tip selection.FAST-AG-SOLUTIONS-
Raven-Rate-Control-Module-FIG-31

Sprayers:
Nozzle capacity at minimum psi, multiply by the number of nozzles.
Example:
For FAST installed tips, see tip chart. 18 x (number of tips) = minimum flow rate.

Applicators

Can be run without entering a minimum flow rate, but if desired, the same formula should be used.FAST-AG-SOLUTIONS-Raven-Rate-Control-Module-
FIG-32

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>