ELATION Chorus Line 8 LED Bar Light User Manual

June 5, 2024
ELATION

ELATION Chorus Line 8 LED Bar Light

ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ELATION brands and product names are trademarks or registered trademarks of their respective companies.

ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040 323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands + 31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu Elation Professional Mexico | AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000
+ 52 728-282-7070

DOCUM ENT VERSION

Due to additional product features and/or enhancements, an updated version of this document may be available online. Please scan the QR Code with your mobile device or visit
www.elationlighting.com for the latest revision/update of this manual before installation and/or programming.


Date

| ****

Document Version

| ****

Software Version ≥

| DMX

Channel Modes

| ****

Notes

---|---|---|---|---
10/19/17| 1| 1.02| 16 / 18 / 46| Initial release.
01/26/18| 1.2| 1.03| NO CHANGE| Added sACN, Pixel Flip, Art-Net/Kling- Net dual control.
07/25/18| 1.4| 1.08| NO CHANGE| Updated manual format.
06/25/20| 1.6| N/C| NO CHANGE| Updated thermal
10/16/20| 1.8| N/C| NO CHANGE| Updated specifications
05/24/21| 2.0| 1.09| NO CHANGE| Updated Software
08/26/21| 2.2| 1.12| NO CHANGE| Updated Software

GENERAL INFORMATION

INTRODUCTION
This fixture has been designed to perform reliably for years when the information in this manual are followed. Please read and understand all the instructions and guidelines carefully and thoroughly before operating this unit. This manual contains important information regarding safety, installation, use, and maintenance.
UNPACKING
Each fixture has been thoroughly tested and shipped in perfect operating condition. Carefully check the outer shipping carton for signs of any damage that may have occurred during shipping. If the outer carton appears to be damaged, carefully inspect the fixture for damage and be sure all included accessories have arrived intact. In the event damage has been found and/or parts are missing, please contact our customer support team for further instructions. Please do NOT return this fixture to your dealer without first contacting customer support at the number listed below. Please do NOT discard the outer shipping carton in the trash. Please recycle whenever possible.
CUSTOMER SUPPORT
Elation Professional provides a customer support line to provide set up help and answer any setup or operation questions. You may also visit us on the web at www.elationlighting.com for any comments or suggestions. For service-related issue please contact Elation Professional.
ELATION SERVICE USA – Monday – Friday 8:00am to 5:00pm PST
Voice: 323-582-3322 Fax: 323-832-9142
E-mail: support@elationlighting.com
ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET
Voice: +31 45 546 85 30 Fax: +31 45 546 85 96
E-mail: support@elationlighting.eu
WARRANTY REGISTRATION / RETURNS
Please register online: http://www.elationlighting.com/Login.aspx to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem, as well as the R.A. number, must also be written down on a piece of paper and included in the shipping container. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. Items returned without a R.A. number clearly marked on the outside of the package will be refused and returned at customer’s expense. You may obtain a R.A. number by contacting customer support.

LIMITED WARRANTY ( USA ONLY)

  1. Elation Professional hereby warrants, to the original purchaser, Elation Professional products to be free of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation Professional product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months (180 days), from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
  2. For warranty service, send the product only to the Elation Professional factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional shall have no liability whatsoever for loss and/or or damage to any such accessories, nor for the safe return thereof.
  3. This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner which Elation Professional concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation Professional factory unless prior written authorization was issued to purchaser by Elation Professional; if the product is damaged because not properly maintained as set forth in the product instructions, guidelines and/or user manual.
  4. This is not a service contract, and this warranty does not include any maintenance, cleaning, or periodic check-up. During the periods as specified above, Elation Professional will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional. All products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to that effect.
  5. Elation Professional reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
  6. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation Professional in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Elation Professional be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product.
  7. This warranty is the only written warranty applicable to Elation Professional products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.

SAFETY GUIDELINES

This fixture is a sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual. Elation Professional is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original rigging parts (omega brackets) included with this fixture should be used for installation. Any modifications to the fixture and/or the included mounting hardware will void the original manufactures warranty and increase the risk of damage and/or personal injury.

  • PROTECTION CLASS 1 – FIXTURE MUST BE PROPERLY GROUNDED

  • THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT.
    DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURES WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURES WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.

  • DO NOT PLUG FIXTURE INTO A DIMMER PACK! NEVER OPEN THIS FIXTURE WHILE IN USE!
    UNPLUG POWER BEFORE SERVICING FIXTURE!
    NEVER TOUCH FIXTURE DURING OPERATION, AS IT MAY BE HOT! KEEP FLAMMABLE MATERIALS AWAY FROM FIXTURE!

  • NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK – MAY INDUCE BLINDNESS! SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK!

  • INDOOR / DRY LOCATIONS USE ONLY! DO NOT EXPOSE FIXTURE TO RAIN AND/OR MOISTURE!

  • DO NOT TOUCH the fixture housing during operation. Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before serving.

  • DO NOT shake fixture, avoid brute force when installing and/or operating fixture

  • DO NOT operate fixture if the power cord is frayed, crimped, damaged and/or if any of the power cord connectors are damaged and do not insert into the fixture securely with ease. NEVER force a power cord connector into the fixture. If the power cord or any of its connectors are damaged, replace it immediately with a new one of similar power rating.

  • DO NOT block any air ventilation slots.

  • All fan and air inlets must remain clean and never blocked.

  • Allow approx. 6” (15cm) between fixture and other devices or a wall for proper cooling. When installing fixtures in a suspended environment, always use mounting hardware that is no less than M10 x 25 mm, and always install fixture with an appropriately rated safety cable.

  • Always disconnect fixture from main power source before performing any type of service and/or cleaning procedure. Only handle the power cord by the plug end, never pull out the plug by tugging the wire portion of the cord.

  • During the initial operation of this fixture, light smoke or smell may emit from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time. Consistent operational breaks will ensure fixtures will function properly for many years.

  • ONLY use the original packaging and materials to transport the fixture in for service.

MAINTENANCE GUIDELINES

DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!

CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output, and extended life. The frequency of cleaning depends on the environment in which the fixture operates: damp, smoky or particularly dirty environments can cause greater accumulation of dirt on the fixture’s optics. Clean the external lens surface at least every 20 days with a soft cloth to avoid dirt/debris accumulation. NEVER use alcohol, solvents, or ammonia-based cleaners.
MAINTENANCE
Regular inspections are recommended to insure proper function and extended life.
There are no user serviceable parts inside this fixture, please refer all other service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from your local Elation dealer. Please refer to the following points during routine inspections: A detailed review by an approved electrical engineer every three months, to make sure the circuit contacts are in good condition and prevent overheating. Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall. Check for any deformations on the housing, color lenses, rigging hardware and rigging points (ceiling, suspension, trussing). Deformations in the housing could allow for dust to enter into the fixture. Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person(s). Electric power supply cables must not show any damage, material fatigue or sediments. NEVER remove the ground prong from the power cable.

FI XTURE OVERVIEW

  1. LCD Menu Display, MENU, UP, DOWN, ENTER Buttons
  2. Tilt Lock
  3. Fuse
  4. Power IN/OUT
  5. 5pin DMX IN/OUT
  6. RJ45 Ethernet IN/OUT

INCLUDED ITEMS
Replacement Lens Covers (x2) Omega Brackets (x2)
Power Cable

INSTALLATION INSTRUCTIONS

FLAMMABLE MATERIAL WARNING
Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or pyrotechnics.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or installations.

USE CAUTION WHEN POWER LINKING OTHER MODEL FIXTURES AS THE POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE. CHECK SILKSCREEN FOR MAX AMPS. DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!

Fixture MUST be installed following all local, national, and country commercial electrical and construction codes and regulations.
Before rigging/mounting a single fixture or multiple interconnected fixtures for custom matrix designs to any metal truss/structure or placing the fixture(s) on any surface, a professional equipment installer MUST be consulted to determine if the metal truss/structure or surface is properly certified to safely hold the combined weight of the fixture(s), clamps, cables, and accessories.
Fixture ambient operating temperature range is 15° to 113°F. (-15° to 45°C)
Do not use the fixture under or above this temperature.
Fixture(s) should be installed in areas outside walking paths, seating areas, or away from areas where unauthorized personnel might reach the fixture by hand.
NEVER stand directly below the fixture(s) when rigging, removing or servicing.
Overhead fixture installation must always be secured with a secondary safety attachment, such as an appropriately rated safety cable that can hold 10 times the weight of the fixture.
Allow approximately 15 minutes for the fixture to cool down before serving.

INSTALLATI ON INSTRUCTIONS

CLAMP MOUNTING
The fixture can be placed on the flat surface or truss mounted. When mounting this fixture to truss be sure to secure (2) appropriately rated clamps (not included) to the (2) Omega Brackets (included) Be sure to attach the Safety Cable (included) to the fixture using the safety cable rigging points integrated into the bottom of the fixture. (See image below)

SAFETY CABLE RIGGING POINT

SAFETY CABLE
The fixture includes an integrated safety cable rigging point. (see image below)

ALWAYS ATTACH A SAFETY CABLE WHEN INSTALLING FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT DROP IF THE CLAMP FAILS. )

INSTALLATI ON INSTRUCTIONS
OVERHEAD RIGGINGELATION Chorus Line 8 LED Bar Light FIG
3
Overhead rigging requires extensive experience, including amongst others calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury and property damage. Fixture is fully operational in the specific mounting positions illustrated below.

POWER LINKING

USE CAUTION WHEN POWER LINKING OTHER MODEL FIXTURES AS THE POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE. CHECK SILK SCREEN FOR AMX AMPS.

KLING-NET / ART-NET CONNECTION
When connecting fixture to a network switch to control multiple devices, a Gigabit Ethernet Switch that supports IGMP (Internet Group Management Protocol) is required. Using a Gigabit Ethernet Switch that does not support IGMP can cause erratic behavior of all connected devices to the switch. Click link below for more information about IGMP.
https://en.wikipedia.org/wiki/Internet_Group_Management_Protocol

SYSTEM MENUELATION Chorus Line 8 LED Bar Light FIG
4
The fixture comes with an easy to navigate system menu. The control panel (see image below) located on the back of the fixture provides access to the main system menu and is where all necessary system adjustments are made to the fixture. During normal operation, pressing MODE button once will access the fixture’s main menu. Once in the main menu you can navigate through the different functions and access the sub-menus with the UP and DOWN buttons. Once you reach a field that requires adjusting, press the ENTER button to activate that field and use the UP and DOWN buttons to adjust the field. Pressing the ENTER button once more will confirm your setting. You may exit the main menu at any time without making any adjustments by pressing the MODE/ESC button.

LCD CONTROL PANEL LOCKOUT
When the Key Lock menu is set to ON, the LCD display will turn OFF after 30 seconds and the (4) button Control Panel will be LOCKED. To unlock the (4) button LCD control panel, press and hold the MODE button.

INFORMATION DISPLAYED DURING INITIAL POWER ON
When the fixture is initially powered ON, the display shows the following information:

SYSTEM MENU

Supports Software Version: ≥ V1.12
Features are subject to change without any prior written notice.
MAIN MENU| SUB MENU| OPTIONS / VALUES (Default Settings in BOLD )| DESCRIPTION
Address| Set DMX Address| 001 ~ XXX| DMX Address Setting

UserMode

| Standard| 18CH (16bit)|

Set DMX Channel Mode

Basic| 16CH (8bit)
Extend| 46CH

Function

|

Status

| Lost DMX| Close/ Hold /Auto. Pro| Function If NO DMX Detected
Tilt. Inv| ON / OFF| Tilt Reverse Movement
Feedback| ON /OFF| Movement Feedback
Move. Spd| Speed 1 ~ 4| Movement Mode Select
Hibernat| OFF, 01M~99M, 15M| Hibernate Mode
Fan. Set| Head Fan| Auto , High, Silent| Fan Speed Set

Net ID

| Password| Password=xxx| Password= 050
DeviceIP| xxx.xxx.xxx.xxx|
Mark Addr| xxx.xxx.xxx.xxx|
Universe| 000-255|
Protocol| ArtNet , SACN| Set Network Protocol
KlingNet| Enable / Disable| Enable KlingNet Protocol
Net| ON / OFF| Activate NET OUT Port.

LCD. Set

| Backlight| 02~60m 05m| LCD Backlight Shut Off Time
FlipDisplay| ON / OFF| Flip/Reverse LCD Display 180º
Key Lock| ON / OFF| Control Front Panel Buttons Key Lock
Flash| ON / OFF| Display flashes when NO DMX
Temp. C/F| Fahrenheit /Celsius| Temperature Switch Between F˚/ C˚

Disp. Set

| ADDR| TILT…| Value of each Channel Displayed
Disp. CH| |
Secondary| Secondary 1 , Secondary 2,

Secondary 3

| Set Secondary Mode Preset
Auto.Pro| Alone , Primary| Set Auto Program Mode
DimCurve| Standard , Stage, TV, Architectural, Theatre, Stage2, 0-10s (Default 0.1s)| Set Dimmer Curve Mode
Frequen| 900/1000/1100/ 1200 /1300/1400/1500/2500/

4000/5000/10k/15k/20k/25k

|
Pixel| Standard , Flip| Set Pixel Flip Mode
DFSE| ON / OFF| Restore Factory Settings

Information

|

Time. Info

| Current| XXXX (Hours)| Fixture Run Time From Power ON
Total| XXXX (Hours)| Fixture Total Run Time
Last| XXXX (Hours)| Clear Fixture Last Run Time
Password Clear/Clear-TO| Password= 050| Password to clear last fixture run time
Password= 060| Password to clear total run time
ON / OFF| Reset Fixture Last Run Time
TempInfo| LED Temp.| XXX / C°| Temperature in Fixture Head
Err. Info| Tilt…..| Display 10 Recent Error Messages
ModelInfo| Chorus Line 8| Display Model Name
Software Version| 1U01 – 5U01| ≥V1.12| Software Versions

Test

| Reset. M| All|
Test. Ch| Tilt …|
ManCtrl| Tilt=XXXX

:

|

Calibrat

| Password

Tilt, Red1, Green1, Blue1, White1…Red8, Green8, Blue8, White8, Zoom1, Zoom2

|

Password= 050

FAN SET -> SILENT: In this mode, the power output drops from 330W to 160w, and slows both the zoom and tilt speed.

DMX CHANNEL UNCT IONS AND VALUES

Supports Software Versions: ≥ V1.12

Features are subject to change without any prior written notice.

*Direction of effects and Pixel Control depends on orientation of the fixture head and Tilt/Pixel Flip settings.

MODE / CHANNEL| VALUE| FUNCTION| DEFAULT| SNAP
BASIC CH: 16| STANDARD CH: 18| EXTEND CH: 46


1

| ****

1

| ****

1

| | TILT Movement 8bit| |
0-255| TILT Movement
| ****

2

| ****

2

| | Tilt Fine 16bit| |
0-255| Fine Control of TILT Movement


2

| ****

3

| ****

3

| | Red| |
0-255| 0 → 100%


3

| ****

4

| ****

4

| | Green| |
0-255| 0 → 100%


4

| ****

5

| ****

5

| | Blue| |
0-255| 0 → 100%


5

| ****

6

| ****

6

| | ALL AMBR| |
0-255| 0 → 100%
| | ****

7

| | Red 2| |
0-255| 0 → 100%
| | ****

8

| | Green 2| |
0-255| 0 → 100%
| | ****

9

| | Blue 2| |
0-255| 0 → 100%
| | ****

10

| | White 2| |
0-255| 0 → 100%
| | ****

11

| | Red 3| |
0-255| 0 → 100%
| | ****

12

| | Green 3| |
0-255| 0 → 100%
| | ****

13

| | Blue 3| |
0-255| 0 → 100%
| | ****

14

| | White 3| |
0-255| 0 → 100%
| | ****

15

| | Red 4| |
0-255| 0 → 100%
| | ****

16

| | Green 4| |
0-255| 0 → 100%
| | ****

17

| | Blue 4| |
0-255| 0 → 100%
| | ****

18

| | White 4| |
0-255| 0 → 100%
Supports Software Versions: ≥ V1.12

Features are subject to change without any prior written notice.

*Direction of effects and Pixel Control depends on orientation of the fixture head and Tilt/Pixel Flip settings.

MODE / CHANNEL| VALUE| FUNCTION| DEFAULT| SNAP
BASIC

CH: 16

| STANDARD

CH: 18

| EXTEND

CH: 46






7

| ****





9

| ****





37

| | Strobe| |
0-31| Closed
32-63| Open
64-95| Strobe (slow → fast)
96-127| Open
128-159| Pulse (slow → fast)
160-191| Open
192-223| Random (slow → fast)
224-255| Open


8

| ****

10

| ****

38

| | Master Intensity| |
0-255| Close → Open


9

| ****

11

| ****

39

| | Master Intensity Fine| |
0-255| Close → Open
10| 12| 40| | Zoom| |
0-255| Zoom Min to Max












11

| ****











13

| ****











41

| | Auto Programs| |
0| Idle
1-14| Off
15-30| Program 1
31-46| Program 2
47-62| Program 3
63-78| Program 4
79-94| Program 5
95-110| Program 6
111-126| Program 7
127-142| Program 8
143-158| Program 9
159-174| Program 10
175-190| Program 11
191-206| Program 12
207-222| Program 13
223-238| Program 14
293-255| Program 15


12

| ****

14

| ****

42

| | Program Speed| ****

128

|
0-255| Speed (slow → fast)


13

| ****

15

| ****

43

| | Program Fade| ****

128

|
0-255| Face (slow → fast)
Supports Software Versions: ≥ V1.12

Features are subject to change without any prior written notice.

*Direction of effects and Pixel Control depends on orientation of the fixture head and Tilt/Pixel Flip settings.

MODE / CHANNEL| VALUE| FUNCTION| DEFAULT| SNAP
BASIC

CH: 16

| STANDARD

CH: 18

| EXTEND

CH: 46





















14

| ****




















16

| ****




















44

| | Dim Modes| ****




















0

| ****




















X

0 – 20| Standard
21 – 40| Stage
41 – 60| TV
61- 80| Archictural
81- 100| Theatre
101- 120| Stage 2
| Dimmer Delay Time
121| 0s
122| 0.1s (default)
123| 0.2s
124| 0.3s
125| 0.4s
126| 0.5s
127| 0.6s
128| 0.7s
129| 0.8s
130| 0.9s
131| 1.0s
132| 1.5s
133| 2.0s
134| 3.0s
135| 4.0s
136| 5.0s
137| 6.0s
138| 7.0s
139| 8.0s
140| 9.0s
141| 10s
142 – 255| Default
0 – 20| Standard
21 – 40| Stage
| | ****


27

| | Pan / Tilt Speed| |
0-225| Max to min speed
226-235| Blackout by movement
236-255| No function
Supports Software Versions: ≥ V1.12

Features are subject to change without any prior written notice.

*Direction of effects and Pixel Control depends on orientation of the fixture head and Tilt/Pixel Flip settings.

MODE / CHANNEL| VALUE| FUNCTION| DEFAULT| SNAP
BASIC

CH: 16

| STANDARD

CH: 18

| EXTEND

CH: 46



























16

| ****


























18

| ****


























46

| | Control| ****


























0

| ****


























X

0 -5| Idle
6-10| Reset
11-15| Fan Mode Auto
16-20| Fan Mode High
21-25| Fan Mode Silent
25-29| Program 1
30-34| Program 2
35-39| Program 3
40-44| Program 4
45-49| Program 5
50-54| Program 6
55-59| Program 7
60-64| Program 8
65-69| Program 9
70-74| Program 10
75-79| Program 11
80-100| Program 12
| Change Refresh Rate (Hz)
101 – 105| 900
106 – 110| 1000
111 – 115| 1100
116 – 120| 1200
121 – 125| 1300
126 – 130| 1400
131 – 135| 1500
136 – 140| 2500
141 – 145| 4000
146 – 150| 5000
151 – 155| 10000
156 – 160| 15000
161 – 165| 20000
166 – 170| 25000
171-200| Idle
| Dimmer Curves
201-210| Dimmer Curve Linear (default)
211-220| Dimmer Curve Square
221-230| Dimmer Curve Inverse Square
231-240| Dimmer Curve S-Curve
241-255| Idle
0 -5| Idle

COLOR MACRO CHART

VALUES 1-4| DMX VALUES 53-56| DMX VALUES 105-108| DMX VALUES 157-160| DMX VALUES 209-212
---|---|---|---|---
Red=| 80| Red=| 255| Red=| 255| Red=| 234| Red=| 0
Green=| 255| Green=| 93| Green=| 138| Green=| 139| Green=| 83
Blue=| 234| Blue=| 182| Blue=| 186| Blue=| 171| Blue=| 115
W=| 80| W=| 93| W=| 138| W=| 0| W=| 0
DMX VALUES 5-8| DMX VALUES 57-60| DMX VALUES 109-112| DMX VALUES 161-164| DMX VALUES 213-216
Red=| 80| Red=| 255| Red=| 255| Red=| 224| Red=| 0
Green=| 255| Green=| 96| Green=| 147| Green=| 5| Green=| 97
Blue=| 164| Blue=| 236| Blue=| 251| Blue=| 97| Blue=| 166
W=| 80| W=| 96| W=| 147| W=| 0| W=| 0
DMX VALUES 9-12| DMX VALUES 61-64| DMX VALUES 113-116| DMX VALUES 165-168| DMX VALUES 217-220
Red=| 77| Red=| 238| Red=| 151| Red=| 175| Red=| 1
Green=| 255| Green=| 93| Green=| 138| Green=| 77| Green=| 100
Blue=| 112| Blue=| 255| Blue=| 255| Blue=| 173| Blue=| 167
W=| 77| W=| 93| W=| 138| W=| 0| W=| 0
DMX VALUES 13-16| DMX VALUES 65-68| DMX VALUES 117-120| DMX VALUES 169-172| DMX VALUES 221-224
Red=| 117| Red=| 196| Red=| 151| Red=| 119| Red=| 0
Green=| 255| Green=| 87| Green=| 138| Green=| 130| Green=| 40
Blue=| 83| Blue=| 255| Blue=| 255| Blue=| 199| Blue=| 86
W=| 83| W=| 87| W=| 138| W=| 0| W=| 0
DMX VALUES 17-20| DMX VALUES 69-72| DMX VALUES 121-124| DMX VALUES 173-176| DMX VALUES 225-228
Red=| 160| Red=| 150| Red=| 138| Red=| 147| Red=| 209
Green=| 255| Green=| 90| Green=| 169| Green=| 164| Green=| 219
Blue=| 77| Blue=| 255| Blue=| 255| Blue=| 212| Blue=| 182
W=| 77| W=| 90| W=| 138| W=| 0| W=| 0
DMX VALUES 21-24| DMX VALUES 73-76| DMX VALUES 125-128| DMX VALUES 177-180| DMX VALUES 229-232
Red=| 223| Red=| 100| Red=| 255| Red=| 88| Red=| 42
Green=| 255| Green=| 77| Green=| 255| Green=| 2| Green=| 165
Blue=| 83| Blue=| 255| Blue=| 255| Blue=| 163| Blue=| 85
W=| 83| W=| 77| W=| 255| W=| 0| W=| 0
DMX VALUES 25-28| DMX VALUES 77-80| DMX VALUES 129-132| DMX VALUES 181-184| DMX VALUES 233-236
Red=| 255| Red=| 77| Red=| 255| Red=| 0| Red=| 0
Green=| 243| Green=| 100| Green=| 206| Green=| 38| Green=| 46
Blue=| 77| Blue=| 255| Blue=| 143| Blue=| 86| Blue=| 35
W=| 77| W=| 77| W=| 0| W=| 0| W=| 0
DMX VALUES 29-32| DMX VALUES 81-84| DMX VALUES 133-136| DMX VALUES 185-188| DMX VALUES 237-240
Red=| 255| Red=| 67| Red=| 254| Red=| 0| Red=| 8
Green=| 200| Green=| 148| Green=| 177| Green=| 142| Green=| 107
Blue=| 74| Blue=| 255| Blue=| 153| Blue=| 208| Blue=| 222
W=| 74| W=| 67| W=| 0| W=| 0| W=| 0
DMX VALUES 33-36| DMX VALUES 85-88| DMX VALUES 137-140| DMX VALUES 189-192| DMX VALUES 241-244
Red=| 255| Red=| 77| Red=| 254| Red=| 52| Red=| 107
Green=| 166| Green=| 195| Green=| 192| Green=| 148| Green=| 156
Blue=| 77| Blue=| 255| Blue=| 138| Blue=| 209| Blue=| 231
W=| 77| W=| 77| W=| 0| W=| 0| W=| 0
DMX VALUES 37-40| DMX VALUES 89-92| DMX VALUES 141-144| DMX VALUES 193-196| DMX VALUES 245-248
Red=| 255| Red=| 77| Red=| 254| Red=| 1| Red=| 165
Green=| 125| Green=| 234| Green=| 165| Green=| 134| Green=| 198
Blue=| 74| Blue=| 255| Blue=| 98| Blue=| 201| Blue=| 247
W=| 74| W=| 77| W=| 0| W=| 0| W=| 0
DMX VALUES 41-44| DMX VALUES 93-96| DMX VALUES 145-148| DMX VALUES 197-200| DMX VALUES 249-252
Red=| 255| Red=| 158| Red=| 254| Red=| 0| Red=| 0
Green=| 97| Green=| 255| Green=| 121| Green=| 145| Green=| 0
Blue=| 77| Blue=| 144| Blue=| 0| Blue=| 212| Blue=| 255
W=| 74| W=| 144| W=| 0| W=| 0| W=| 0
DMX VALUES 45-48| DMX VALUES 97-100| DMX VALUES 149-152| DMX VALUES 201-204| DMX VALUES 253-255
Red=| 255| Red=| 255| Red=| 176| Red=| 255| Red=| 0
Green=| 71| Green=| 251| Green=| 17| Green=| 0| Green=| 0
Blue=| 77| Blue=| 153| Blue=| 0| Blue=| 0| Blue=| 0
W=| 71| W=| 153| W=| 0| W=| 0| W=| 255
DMX VALUES 49-52| DMX VALUES 101-104| DMX VALUES 153-156| DMX VALUES 205-208|
Red=| 255| Red=| 255| Red=| 96| Red=| 0| |
Green=| 83| Green=| 175| Green=| 0| Green=| 255
Blue=| 134| Blue=| 147| Blue=| 11| Blue=| 0
W=| 83| W=| 147| W=| 0| W=| 0

PIXEL CONTROL

STANDARD

ELATION Chorus Line 8 LED Bar Light FIG 6

FLIPELATION Chorus Line 8 LED Bar Light FIG 7

The fixture features pixel control in Extended DMX channel mode. See diagram below, which illustrates the specific pixel mapping order.

TECHNICAL SPECIFICATIONS

SOURCE

  • (8) 40W 4-in-1 RGBW LEDs
  • 50,000 Hour Average LED Life*
  • *May vary depending on several factors including but not limited to:
  • Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming.

PHOTOMETRIC DATA

  • 3,000+ Total Lumens
  • 8,702 LUX 809 FC @16.4 ft (5m) (Full ON (4° Min Zoom)
  • 318 LUX 21 FC @16.4 ft (5m) (Full ON (37° Max Zoom)
  • Zoom Range 4° – 40°
  • Beam Angle 4.6° – 37.8°
  • Field Angle 7.8° – 54.4°

EFFECTS

  • Motorized Zoom and 220° Tilt Movement
  • RGBW Color Mixing and Full Pixel Control
  • 2,700K – 7,000K Linear Color Temperature
  • 64 Color Presets and 14 Unique Color Macros
  • Electronic Strobe, 16-bit Variable Dimming Curve Modes

COLOR

  • RGBW

CONTROL / CONNECTIONS

  • 3 DMX Channel Modes (46 total channels)
  • DMX, RDM, Kling-Net, and Art-Net Protocol Support
  • Adjustable LED Refresh Rate (900-25,000 Hz)
  • Adjustable LED Gamma Brightness (2.0, 2.2, 2.4, 2.8)
  • 4 Button Touch Control Panel
  • 180° Reversible LCD Menu Display
  • 8 / 16-Bit Resolution Zoom and Tilt Movement
  • 5pin DMX In/Out
  • RJ45 Ethernet In/Out
  • Locking Power Cable Power In/Out
  • With Wired Digital Communication Network

SIZE / WEIGHT

  • Length: 21.28″ (540.5mm)
  • Width: 7.44″ (189mm)
  • Vertical Height: 11.46″ (291mm)
  • Weight: 25.0 lbs (11.3 kg)

ELECTRICAL / THERMAL

  • AC 100-240V – 50/60Hz
  • 359W Max Power Consumption
  • 5°F to 113°F (-15°C to 45°C)
  • BTU/hr (+/- 10%) 1224.2
  • APPROVALS / RATINGS

DIMENSIONAL DRAWINGS

ELATION Chorus Line 8 LED Bar Light FIG
8

OPTIONAL ACCESSORIES

ORDER CODE ITEM
DRCCL8 6-Pack Road Case for Chorus Line 8
NARROW CLAMP Heavy Duty Wrap Around Hook Style Clamp
AC5PDMX5PRO 5 ft. (1.5m) 5pin PRO DMX Cable
PLC3 3 ft. (1m) PRO Link Cable
Additional Cable Lengths Available

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device uses and can radiate radio frequency energy and, if not installed and used in accordance with the included instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following methods:

  • Reorient or relocate the device.
  • Increase the separation between the device and the receiver.
  • Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Europe Energy Saving Notice
Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help to protect the environment. Please turn off all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ELATION User Manuals

Related Manuals