samplexpower BW-01 Battery Monitor Owner’s Manual
- June 5, 2024
- samplexpower
Table of Contents
BATTERY MONITOR BW-01
OWNER’S MANUAL
Description and Features:
This unit is an Intelligent, microprocessor-based, panel-mounted battery voltage monitor for display of the State of Charge of 12V / 24V battery with the help of a buzzer and different patterns of Red / Yellow / Green LEDs: steady/blinking/slow or fast “Walking LEDs”. 12V / 24V battery is detected automatically when the voltage of 7 to 32V is seen on the connection of the battery. Following parameters/conditions are displayed: · Terminal voltage
- Charging in progress
- Alarm at programmed low voltage threshold.
- Alarm at programmed high voltage threshold
- 3- Day Timer / Switch OFF the unit for low voltage protection
Layout and Dimensions
Fig 1.:
- Red LED
- Yellow LED
- Green LED
- Buzzer (at the back)
- Programming Button
Fig 2.:
A 1/4″ (6.3mm) Quick Connect Tab Terminal for connection to Positive
(+) of the battery
B 1/4″ ( 6.3mm) Quick Connect Tab Terminal for connection to Negative
(-) of the battery
Installation:
Please refer to Figs 1 and 2 above. The unit consists of a 65 x 65 mm front
plate with 4 x 3.2 mm holes for flush mounting on a wall/panel with 4 screws
(#4, Tapping, Flat Head). The Printed Circuit Board (PCB) and Battery Input
Connectors (0.25″/ 6.3 mm Quick Connect Tabs) are located at the back of the
plate and project out to a depth of 25.5 mm. For flush mounting on the
wall/panel, a pocket/slot measuring 30 mm x 30 mm x 40 to 50 mm depth is
required to be made to accommodate the projection at the back.
Use AWG # 22 to 26 wires (e.g. telephone wires) to connect to the battery (See
Fig. 2). Use a 0.5A fuse in series with the Positive wire. The fuse should be
as close as possible to the battery Positive terminal (preferably within 7″).
Refer to Fig 2. Battery Positive (+) and Negative (-) connections to the unit
are made through Battery Input Connectors “A” and “B” (1/4″/6.3 mm Male Quick
Connect Tabs). For this connection, use 0.25″/6.3 mm Female Quick Connect
Receptacle Terminal Lugs on the wire ends (See Fig 3).
12V / 24V battery is detected automatically when the voltage of 7 to 32V is
seen on the connection of the battery. At startup, Red LED is activated as a
sign of power-up. After some time, the unit is initialized and the 12V / 24V
battery is recognized. The State of Charge is displayed thereafter.
LED and Buzzer Indications for Voltage Levels:
*NOTE: The term “Walking LEDs” has been used to indicate cyclical,
sequential lighting patterns of Red, Yellow, and Green LEDs. This pattern
indicates that charging is taking place. The following 2 patterns are used:
- “Walking LED’s – Fast” + Beep : Indicates charging at voltage that is higher than the programmed value of High Voltage Threshold (14.8V (Preset) / 15.3V / 16V for 12V battery and 29.6V (Preset) / 30.6V / 32.0V for 24V battery). The loop is: {Red » Yellow » (Green + Beep) » All OFF}… repeats this sequential loop.
- “ Walking LED’s Slow” : Indicates charging at a voltage higher than 13.3V (12V battery) / 26.6V (24V battery) but lower than the programmed value of High Voltage
Threshold (14.8V (Preset) / 15.3V / 16V for 12V battery and 29.6V (Preset) / 30.6V / 32.0V for 24V battery). The loop is: (Red » Yellow » Green» All OFF)… repeats this sequential loop.
Status of LEDs and Buzzer| Battery Voltage indicated for 12V
Battery| Battery Voltage indicated for 24V Battery
---|---|---
Walking LED’s – Fast + Beep (Indicates charging in progress and the voltage is higher than the programmed threshold of Over Voltage Alarm)| > 14.8 (Preset) /
15.3V / 16.0V| > 29.6V (Preset) /
30.6V / 32.0V
Walking LED’s – Slow (Indicates charging in progress under normal conditions)| > 13.3 But <(14.8V
(Preset) / 15.3V /
16.0V)| > 26.6V But < (29.6V
(Preset) / 30.6V /
32.0V)
Green| > 12.4| > 25.0V
Green+Yellow| > 11.6| > 23.2V
Yellow| > 11.2| > 22.2V
Yellow+Red| > 10.9| > 21.8V
Red| > 10.5| >21.4V
(Green +Yellow + Red) – Blinking| –| > 21V
The following pattern indicates voltage is below the programmed threshold for
the Low Voltage Alarm:
(Red + Green) » (Yellow + Beep)… repeat 10 times
» (Red + Green) » (Yellow)… repeats 10 times
» All LEDs OFF. Unit enters
Sleep Mode. There is a beep every min.| < 10.5 (Preset) or < programmed values
of 10.6V / 10.7V / 10.8V /10.9V/11.0V /11.1V/11.2V /21.6V/21.8V| < 21 V
(Preset) or < programmed values
of 21.2V / 21.5V / 22.0V / 22.2V / 22.4V
High Voltage Alarm during Charging:
Following voltage thresholds can be programmed to warn about overvoltage
conditions during charging (See programming procedure given separately).
- 14.8V (Preset) / 15.3V / 16V for 12V battery
- 29.6V (Preset) / 30.6V / 32.0V for 24V battery
This facility can be used to indicate the onset of the “Equalization Stage”
when charging Flooded / Wet Cell Batteries. During “Equalization Stage”, the
battery is intentionally overcharged to 15.3 to 16V (12V battery) / 30.6 to
32V (for 24V battery) for limited time of 1 to 3 Hrs. During this time, it is
necessary to monitor the battery for overheating / electrolyte
level/measurement of individual cell voltages and for turning OFF Equalization
at the appropriate time.
The display pattern is “Walking LEDs Fast” + Beep. In this pattern, the
display/buzzer loop is: {Red » Yellow » (Green + Beep) » All OFF}……Repeats
this sequential loop.
NOTE: The unit will not reset even after the battery voltage drops below
the programmed Over Voltage Threshold. This is helpful to know that an
overvoltage condition existed. The alarm can be reset manually as follows: ·
Press and hold the Programming Button » Beep will be heard » Release the
Button
Low Voltage Alarm: Following voltage, thresholds can be programmed to
warn
about low voltage conditions (See programming procedure given separately).
- < 10.5 (Preset) or < programmed values of 10.6V / 10.7V / 10.8V / 10.9V / 11.0V /11.1V / 11.2V
- < 21V (Preset) or < programmed values of 21.2V / 21.5V / 21.6V / 21.8V / 22.0V / 22.2V / 22.4V
When the programmed Low Voltage Threshold is reached, the following LED / Buzzer pattern will be observed:
- (Red + Green) » (Orange + Beep)…….Repeats 10 times
- (Red + Green) » (Orange)….. Repeats 10 times
- All LEDs OFF. The unit enters Sleep Mode. There is a beep every minute so that it is clear that the unit is not in a “3 Day Off Mode.”
NOTE: The unit will reset only when the battery voltage rises to > 13.3V
(for 12 V battery) / 26.6 V (for 24V battery) i.e. when charging takes place.
3-Day Timer :
A 3-Day Timer has been provided to automatically switch OFF the unit after 3
days of switching ON of the Timer or if the battery voltage drops below 10.4V
(for 12V battery) or 20.8V (for 24V battery). The Timer will be automatically
switched OFF after the battery voltage rises above 13,3V (for 12V battery) or
26.6V (for 24V battery).
ON / OFF Modes can be programmed as shown under the heading “Programming Alarm
Thresholds / 3-Day Timer.”
Programming Procedure: Brightness of LED Display:
The unit comes preset with the brightness of the LEDs set at Normal (Bright).
The brightness can be dimmed or the LEDs can be switched OFF. Settings can be
changed with the help of the Programming Button (5, Fig 1). Settings are
performed in sequential order in a loop: Bright » Dim » OFF » Bright » Dim »
OFF… repeats the loop.
For changing the Setting: Press and hold the Programming Button » Beep will be
heard » Release the Button.
Please note that when the LED display is switched OFF, the Buzzer alarm
protocols stay active in the background. Hence, if the Under Voltage / Over
Voltage condition is activated, the LED display and Buzzer alarm protocols for
the abnormal condition will be activated.
Programming Procedure: Alarm Thresholds / 3-Day Timer
Thresholds of Low Voltage / High Voltage Alarms and Timer ON / OFF settings
are programmed with the help of the Programming Button (5, Fig 1) and by
monitoring the LED and Buzzer indication patterns.
CAUTION! Alarm thresholds are to be programmed only when the voltage is
between 10.5V and 13.3V (for 12V battery) and between 21V and 26.6V (for 24V
battery). In this condition, the LEDs / Buzzer will not be indicating (i)
“charging” i.e., will not be displaying “Walking LEDs Fast+Beep” or “Walking
LEDs Slow” or (ii) “Low or High Voltage Alarm”.
Programming Modes are SEQUENTIAL as shown in the sequence given below. This
means that in order to access the programming of the desired parameter, it
will be necessary to pass through the previous programming positions. Press
Programming Button (5, Fig 1) and hold it in pressed condition. Release the
Button ONLY when the LED + Beeping pattern for the desired parameter is
displayed.
The sequence starts with Programming Mode for Low Voltage Thresholds first
followed by High Voltage Thresholds and then followed by Timer ON/OFF.
Before the start of each Programming Mode, all the 3 LEDs and buzzers will
blink simultaneously 3 times.
To START, press the Programming Button (5, Fig 1) and hold it in pressed
condition. Release the Button ONLY when the LED + Beeping pattern for the
desired parameter is displayed.
» Long beep » {(Red+Yellow+Green+Beep) » (Red+Yellow+Green+Beep)}… 3 Times
(Low Voltage Threshold Programming Menu starts)
THE LOW VOLTAGE MENU STARTS | 12V Battery | – 24V battery ° |
---|---|---|
(Red + Beep) – 3 blinks | 10.5V (Preset) | 21V (Preset) |
(Red + Beep) – Steady | 11. | 21. |
(Red + Yellow + Beep) – 3 Blinks | 10.7V | 21.5V |
(Red + Yellow + Beep) – Steady | 10.8V | 21.6V |
(Yellow + Beep) – 3 Blinks | 10.9V | 21.8V |
(Yellow + Beep) – Steady | 11.0V | 22.0V |
(Yellow + Green + Beep) – 3 Blinks | 11.1V | 22.2V |
(Yellow + Green + Beep) – Steady | 11.2V | 22.4V |
ffRed+Yellow+Green+Beep) » (Red+Yellow+Green+Beep)}… 3Times (High Voltage Threshold Programming Menu starts)
THE HIGH VOLTAGE MENU STARTS| 12V Battery 24V battery
Steady Red + Long Beep| 14.8V 29.6V
|
Steady Yellow + Long Beep| 15.3V 30.6V
|
Steady Green + Long Beep 1| 16.0V 32.0V
|
Long Pause
(3-Day timer Programming Menu Starts)
3 DAY TIMER ACTIVATION|
Short Beep (No LED)| 3-Day Timer ON
|
Long Pause|
3 DAY TIMER DE-ACTIVATION|
Long Beep (No LED)| 3-Day Timer OFF
Programming sequence ends. Release Programming Button
Specifications
Battery System Voltage ………………………. 12V / 24V (Auto Detection)
Input voltage Range ………………………………………..7 VDC to 32 VDC
Input current ………………………………………………….. Less than 30 mA
Battery Input Connectors …….¼” / 6.3 mm Male Quick Connect Tabs
Input Wiring …………………………………………………….AWG # 22 to 26
Fuse* ……………………………………………………………………………..0.5A
Dimensions, mm…………………………………………………. 65 x 65 x 25.5
Weight ………………………………………………………………………… 35 gm
- In series with Positive wire preferably within 7” from the Battery Positive
YEAR LIMITED WARRANTY
Battery Monitor BW-01 manufactured by Samlex America, Inc. (the “Warrantor“) is warranted to be free from defects in workmanship and materials under normal use and service. The warranty period is 2 years for the United States and Canada and is in effect from the date of purchase by the user (the “Purchaser“).
Warranty outside of the United States and Canada is limited to 6 months. For a
warranty claim, the Purchaser should contact the place of purchase to obtain a
Return Authorization Number.
The defective part or unit should be returned at the Purchaser’s expense to
the authorized location. A written statement describing the nature of the
defect, the date of purchase, the place of purchase, and the Purchaser’s
name, address, and telephone number should also be included.
If upon the Warrantor’s examination, the defect proves to be the result of
defective material or workmanship, the equipment will be repaired or replaced
at the Warrantor’s option without charge and returned to the Purchaser at the
Warrantor’s expense. (The contiguous US and Canada only)
No refund of the purchase price will be granted to the Purchaser unless the
Warrantor is unable to remedy the defect after having a reasonable number of
opportunities to do so.
Warranty service shall be performed only by the Warrantor. Any attempt to
remedy the defect by anyone other than the Warrantor shall render this
warranty void. There shall be no warranty for defects or damages caused by
faulty installation or hook-up, abuse or misuse of the equipment including
exposure to excessive heat, salt or freshwater spray, or water immersion.
No other express warranty is hereby given and there are no warranties which extend beyond those described herein. This warranty is expressly in lieu of any other expressed or implied warranties, including any implied warranty of merchantability, fitness for the ordinary purposes for which such goods are used, or fitness for a particular purpose, or any other obligations on the part of the Warrantor or its employees and representatives.
There shall be no responsibility or liability whatsoever on the part of the Warrantor or its employees and representatives for injury to any persons, damage to person or persons, damage to property, loss of income or profit, or any other consequential or resulting damage which may be claimed to have been incurred through the use or sale of the equipment, including any possible failure of malfunction of the equipment, or part thereof. The Warrantor assumes no liability for incidental or consequential damages of any kind.
Samlex America Inc. (the “Warrantor”)
www.samlexamerica.com
DETAILED PRODUCT INFORMATION
For a complete user manual including specifications, application notes,
installation instructions, troubleshooting, and more, please visit the web
page for this product on
www.samlexamerica.com. The product page can
be found using the “Search by Model” field.
SAMLEX AMERICA, INC.
Documents / Resources
|
samplexpower BW-01 Battery
Monitor
[pdf] Owner's Manual
BW-01, Battery Monitor
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>