kranzle K 1152 TS High-Pressure Cleaner User Manual
- June 5, 2024
- kranzle
Table of Contents
K 1152 TS High-Pressure Cleaner
EN Operating manual
High-pressure cleaner K 1152 TS K 1152 TST
www.kraenzle.com
Operating manual
EN
High-pressure cleaner
K 1152 TS K 1152 TST
Operating manual! This manual is a translation of the original manual. Read and conform safety instructions before use! Technical data will be found in the Spare parts list. Please be aware that the spare part list is part of the operating manual. Keep both leaflets for later use or any subsequent owners.
2
3
Contents
Dear customer,
we would like to congratulate you on the purchase of your new high-pressure
cleaner and thank you for your confidence in our products!
Your choice has fallen on an absolute quality product! Kränzle high-pressure
cleaners are characterized by their convenient and compact design as well as
their high suitability for everyday use.
Highest precision and dimensional accuracy in addition to a technology package
consisting of a multitude of details mark the difference when it comes to
performance, safety and durability.
In order to facilitate handling of the high-pressure cleaner, the following
pages are intended to further explain its use. The illustrations may be
subject to deviation depending on the type of equipment or accessory of high-
pressure cleaner purchased by you.
Contents ……………………………………………………………………………………. 4 Explanatory symbols
…………………………………………………………….. 5 Safety notes …………………………………………………………………………….. 6
Description of high-pressure cleaner ………………………………… 10 General rules
……………………………………………………………………………. 14 Functional details
…………………………………………………………………… 16 Putting into operation …………………………………………………………..
20 Applying additives …………………………………………………………………. 24 Taking out of operation
………………………………………………………… 25 Small repairs – do it yourself …………………………………………………
26 Kränzle accessories ………………………………………………………………… 30 EU Declaration of
Conformity ……………………………………………… 32 Warranty ………………………………………………………………………………….. 33
Inspection reports ………………………………………………………………….. 34
4
Explanatory symbols
Explanatory symbols used in the operating manual
Failure to observe this note may entail environmental damage.
Note on the use of the high-pressure cleaner that failure to adhere to the
instructions may cause excessive wear or total breakdown of the K 1152-series.
Warning! Failure to observe this note may result in serious injuries!
Explanatory symbols affixed to the high-pressure cleaner
The high-pressure cleaner must be operated in horizontal position! In case of
improper use, the high-pressure jets can be very dangerous. Do not direct
high-pressure jet at persons, animals or active electrical equipment or the
high-pressure cleaner itself.
The high-pressure cleaner may not be connected directly to the public drinking
water supply network.
Risk of burns due to hot surfaces!
Products marked with this symbol may contain constituents posing a risk to
health or the environment if incorrectly disposed of. These products must
never be disposed of as household waste.
Explanatory symbols affixed on the packaging
This symbol denotes recyclable packaging materials which must not be disposed
of as household waste. Information on proper disposal will be gathered from
the recycling directives issued by your local authority.
5
Safety notes
User operating the high-pressure cleaner should wear the necessary protective
clothing, i.e. waterproof clothing, rubber boots, safety goggles, ear
protection headwear etc. It is prohibited to use the high-pressure cleaner in
close vicinity to people lacking suitable protective clothing.
Use of high-pressure cleaners may result in aerosols being generated. An
aerosol is a mixture of floating solid or liquid particles in a gas. Inhaling
aerosol particles may cause damage to health. Employers are under obligation
to carry out a hazards assessment in order to determine the necessary
protective measures to prevent inhalation of aerosols as governed by the
surface due to be cleaned in each case. Respiratory masks, Class FFP 2 or
higher, are suitable for protection against aqueous aerosols.
Whenever the high-pressure cleaner is left unattended, the mains disconnect
switch must always be switched off.
Do not spray against matter containing asbestos or other hazardous substances!
Never spray flammable liquids or liquids containing solvents such as paint
thinners, petrol, oil or similar liquids! Explosion hazard due to spraying
such materials!
Due to the high-pressure jet, damage may occur on the objects to be cleaned,
e.g. car tires; therefore, a minimum distance of 30 cm is to be kept!
Prior to putting the high-pressure cleaners into operation, check its
components (High-pressure hose, power supply cables, safety trigger gun) for
any damage. Replace defect or damaged components!
Only use high-pressure hoses, couplings and fittings recommended by Kränzle.
Only these accessories ensure safety of the equipment.
If use is made of an extension cable, this must be suitable for outdoor use.
In addition care needs to be taken to ensure that the cable is kept dry and
that it is situated above the ground. We recommend the use of a cable drum
capable of keeping the socket at least 60 mm above the ground.
6
Safety notes – This is prohibited!
Replacement of the power supply cables is only permitted by use of an original
power supply cable of the manufacturer and must be performed by a qualified
electrician. Safety devices serve to protect the user and must never be de-
activated or their function bypassed. The high-pressure cleaner is to be
properly used. The user is required to adhere to local requirements and to
watch out for the persons in the danger zone! If used in elevated positions
where there is a risk of the unit falling to the ground, it must be secured
against rolling away or tipping over. The high-pressure cleaner is not
designed for use by persons with restricted physical, sensory or mental
abilities (including children)!
When using high-pressure water for cleaning, make sure that there is a clearly
noticeable recoil effect on the lance. Therefore ensure a firm footing (see
technical data).
Never allow children or untrained persons to use the high-pressure cleaner or
to play with it! Children must be kept under supervision to prevent them from
playing with the equipment.
7
Safety notes – This is prohibited!
Never direct the high-pressure jet at the highpressure cleaner itself! The
high-pressure cleaner may not be placed within reach of the highpressure jet
spray mist!
Never direct the high-pressure jet at power sockets or any other electrical
installations! Within the working area, all live parts are to be protected
from both water jet and spray mist.
Always pay attention to the underbody lance resting on the surface! Bear in
mind when using a curved or angled spraying lance that there is a significant
amount of torque in the recoil! (The underbody lance is available as optional
accessory).
Apply the safety catch on the safety trigger gun after each use in order to
prevent unintentional spraying!
8
Safety notes – This is prohibited!
Never direct the high-pressure jet at people or animals! Never direct the
high-pressure jet at yourself or other persons, not even to clean clothing or
shoes.
Only use a power supply cable in perfect working order! Do not damage or
improperly repair the power cable (tearing, squeezing, running over, …).
Never pull the high-pressure hose if it has formed kinks or “nooses”! Never
pull the high-pressure hose over sharp edges!
9
Description of high-pressure cleaner
Design: K 1152-series without hose drum
The K 1152 TS cleaner is a mobile high-pressure cleaner with an advanced
arrangement system. Please see construction scheme for more details.
1 11
7
4 5
2 3
12
6
8
9
10
1. Ergonomically shaped handle
2. Pump head made of special brass
3. Cleaning agent injection hose
4. Large stainless steel pressure gauge
5. Start/Stop switch
6. Storage for safety trigger gun
7. Safety trigger gun
8. Lances in storage
9. On/Off switch with motor protection
10. Integrated trolley takes steps and rough ground in its stride
11. Cable reel for the power supply cable
12. Infinitely variable pressure and quantity regulation
10
Description of high-pressure cleaner
This is what you have purchased: K 1152-series without hose drum
1. Kränzle high-pressure cleaner K 1152 TS
2. Safety trigger gun with plug coupling
3. Dirtkiller lance with stainless steel pipe and quick release coupling
4. Vario-Jet lance with stainless steel pipe and quick release coupling
5. Crank handle with two fastening screws for the power supply cable
6. Operating manual Spare parts list
7. High-pressure hose
11
Description of high-pressure cleaner
Design: K 1152-series with hose drum
The K 1152 TST cleaner is a mobile high-pressure cleaner with an advanced
arrangement system. Please see construction scheme for more details.
1 12
8
5 6
3
2 4
13
7
9
10
11
1. Ergonomically shaped handle
2. Pump head made of special brass
3. Hose drum with 15 m steel weave high-pressure hose
4. Cleaning agent injection hose
5. Large stainless steel pressure gauge
6. Start/Stop switch
7. Storage for safety trigger gun
8. Safety trigger gun
9. Lances in storage
10. On/Off switch with motor protection
11. Integrated trolley takes steps and rough ground in its stride
12. Cable reel for the power supply cable
13. Infinitely variable pressure and quantity regulation
12
Description of high-pressure cleaner
This is what you have purchased: K 1152-series with hose drum
1. Kränzle high-pressure cleaner K 1152 TST
2. Safety trigger gun with plug coupling
3. Dirtkiller lance with stainless steel pipe and quick release coupling
4. Vario-Jet lance with stainless steel pipe and quick release coupling
5. Crank handle with two fastening screws for the power supply cable
6. Operating manual Spare parts list
7. Crank handle with fastening screw
13
General rules
Intended use
This high-pressure cleaner is to be used solely for high-pressure water jet
cleaning applications without detergents or low-pressure cleaning work with
detergents (e.g. with a foam injector or washing brush).
Environmental, refuse disposal and water protection regulations must be
observed!
Inspections
The high-pressure cleaner must be inspected according to the “Guidelines for
Liquid Spray Devices” at least once every 12 months by a qualified person, to
ensure that continued safe operation is guaranteed. The results of the
inspection are to be recorded in writing (see Inspection reports).
High-pressure cleaners used for commercial purposes have to be checked by a
qualified person at least every 12 months!
Accident prevention
The high-pressure cleaner is designed for accidents to be impossible if used
correctly. The user is to be notified of the risk of injury from hot machine
parts and the high-pressure jet. The “Guidelines for Liquid Spray Devices”
must be complied with.
General rules
Oil change
The first oil change should be carried out after approximately 50 operating hours, then every year or after 250 operating hours. If the oil turns grey or white, you must change the oil. In case of exchanging oil being required, the oil drain screw must be opened above a container and the high-pressure cleaner be emptied. The oil is to be caught in the reservoir and disposed of in an approved manner.
New oil: 0.25 l Kränzle High Performance Gear Oil (Ord. no.: 400932)
Oil leakage If oil leaks contact your nearest after-sales service (dealer) at
once. Failure to observe this instruction may cause damage to the environment
and/or transmission gearbox.
In case of increased humidity or fluctuations in temperature development of
condensed water is possible. If the oil turns grey or white, you must change
it.
14
15
Functional details
Please note: Lack of water
Lack of water occurs more often than you probably believe. The more powerful a
highpressure cleaner is the greater is the danger that a lack of water occurs.
If there is only an insufficient amount of water available, cavitation (water-
gas mixture) arises inside the high-pressure pump, which is normally noticed
too late or even not at all. The highpressure pump will be destroyed. Please
check the available quantity of water by filling a bucket with liter scale for
one minute.
Required minimum quantity of water (see technical data).
If the metered quantity of water is too small, you have to use a different
water connection, guaranteeing the necessary output. Lack of water leads to an
accelerated wear of the joints (no warranty).
Never let the high-pressure pump run dry for more than 60 seconds.
Water supply
Please pay attention to the regulations of your waterworks company! In
accordance with DIN EN 61770, the high-pressure cleaner may not be directly
connected to the public drinking water supply lines. A brief connection
however is permissible according to DVGW (German Association for Gas and Water
Affairs) if a non-return valve with tube ventilator (Kränzle item no.: 410164)
is built into the water supply. Once the water has passed through the non-
return valve it is no longer considered as drinking water. Also indirect
connection to the public drinking water supply lines is permissible by way of
free emission in accordance with EN 61 770; e.g. by using a reservoir with a
float valve. Direct connection to a non-drinking water supply line is
permissible.
16
Functional details
Insufficient quantity of electricity
If there are too many collectors in your proximity connected to the network at
the same time, the available voltage and the current intensity may decline.
Consequently the motor of the high-pressure cleaner does not start or even
blows. The power supply may also be insufficient if the power supply cable is
too long or too thin. If extension cables are too long, this may lead to a
voltage drop causing malfunctions or start-up difficulties.
Check the line fusing and have the voltage and the available current intensity
checked by an expert in case of uncertainty (see technical data).
Electrical connection
The high-pressure cleaner is supplied with a 5 meters long power supply cable.
The mains plug must be fitted to a standard grounded socket with a 30 mA
residual current operated device. Connection up to the mains must be carried
out by a properly trained electrician and must comply with the requirements of
IEC60364-1. The socket must be protected with a 16 A fuse on the mains side.
When using an extension cable, this must have an earthed lead which is
properly connected to the socket. The conductors in the extension cable must
have a minimum cross section of 1.5 mm². Plug connections must be of a spray-
proof design, and may not be located on a wet floor. For extension cables of
more than 10 m in length, the minimum cross-section must be 2.5 mm²! When
using a cable drum, the power supply cable always must be unwound all the way.
17
Functional details
Water and cleaning system
Water can be connected at mains pressure to the high-pressure pump. The water
is then forced under pressure by the high-pressure pump to the lance. The
high-pressure jet is formed by the nozzle at the end of the lance.
Environmental, refuse disposal and water protection regulations must be
observed!
Safety jet pipe with safety trigger gun
The high-pressure cleaner can only be operated when the trigger of the safety
deactivation trigger gun`s trigger is actuated. When the trigger is pulled,
the safety trigger gun opens. The liquid is then transported to the nozzle.
The spray pressure increases and quickly reaches the operating pressure. When
the trigger is released, the safety trigger gun closes and any further
spraying of liquid from the safety jet pipe is prevented. The stainless steel
pressure gauge must show 0 bar. The increase in pressure when the safety
trigger gun is closed causes the pressure control valve/safety valve to open.
The motor is switched off by the pressure switch. When thesafety trigger gun
is opened, the pressure control valve/safety valve closes, the motor is
started and the high-pressure pump resumes pressure spraying from the safety
jet pipe with the selected operating pressure.
The safety trigger gun is a safety device. Repairs should only be performed by
qualified persons. Should replacement parts be required, use only components
authorized by the manufacturer.
Pressure control valve/safety valve
The pressure control valve/safety valve protects the high-pressure cleaner
from a build up of excess pressure, and is designed not to permit an excess
pressure to be selected for operation. The limit nut on the handle is sealed
with a spray coating. The operating pressure and spray rate can be steplessly
adjusted by turning the handle.
Replacements, repairs, new adjustments and sealing should only be performed by
qualified persons.
18
Functional details
Motor protection switch
Motor is protected against overload by means of a motor protection switch. In
case of motor overload or blocking, the motor of the high-pressure cleaner
switches off automatically. If motor tends to switch off repeatedly, make sure
to detect appears. Make sure to detect and remedy the cause of the failure.
Replacements and inspection work should only be performed by qualified persons
when the high-pressure cleaner is disconnected from the power supply, i.e.
with plug pulled out from the electrical socket.
Totalstop system
The K 1152-series features a totalstop system. If the main switch is switched
on, the motor is started via a pressure switch when opening the safety trigger
gun. When closing the safety trigger gun the motor is switched off
immediately.
High-pressure hose and spray device
The high-pressure hose and spray device which are part of the K 1152-series
equipment, are made of high quality material and engineered to conform with
the operating conditions of the high-pressure cleaner and are duly labeled.
If replacement parts are required, only such parts that are authorized by the
manufacturer may be used. The warranty is automatically void if spare parts of
third-party providers are used! The high-pressure hose and spray device must
be connected in a pressure-tight manner (without leakage).
The high-pressure hose may not be driven over, pulled excessively, or twisted.
The high-pressure hose may under no circumstances be pulled over sharp edges.
Defective high-pressure hoses must not be repaired (acc. to DIN 20022) but
have to be replaced by new hoses approved by the manufacturer.
Prior to putting the high-pressure cleaner into operation make sure that all
safety instructions be observed.
19
Putting into operation
1. Use the supplied screws to fasten the lower cable retractor of the power
supply cable in the place provided on the frame.
2. For high-pressure cleaners with hose drum the enclosed hand crank mus be
applied prior to first operation. For this purpose, please set up the high-
pressure cleaner. Plug the hand crank onto the hexagon and attach it with the
enclosed screw and washer.
3. Move high-pressure cleaner to the job site. The K 1152-series is a movable
high-pressure cleaner with sturdy trolleys ideally suited for difficult
terrain and stairs.
The high-pressure cleaner must be operated in horizontal position!
It is imperative that safety instructions be observed during use of the high-
pressure cleaner.
Neither set up or operate the K 1152-series in rooms where there is a risk of
fire or explosion nor put it into puddles. Do not use the highpressure cleaner
under water. If, none the less, the high-pressure cleaner is operated in a
hazardous area, the applicable safety regulations are to be observed.
20
Putting into operation
4. For high-pressure cleaners with hose drum, however, it must be uncoiled
completely. For high-pressure cleaners without hose drum the high-pressure
hose included in the scope of the delivery must be screwed with the pump
outlet in a tight and pressure tight manner. Unwind high-pressure hose
straight and without nooses. The high-pressure hose may leave signs of
abrasion on some floors. Alternatively, please also find non-marking high-
pressure hoses in our range.
5. Mount the grey rotating screw connection of the high-pressure hose onto
the trigger gun incorporating a safety catch. Afterwards screw together
ensuring a snug and pressure-tight fit.
6. First pull back the retaining sleeve of the safety trigger gun, then
insert lance into the plug coupling sconnection of the safety trigger gun.
7. After insertion of the lance, release retaining sleeve and make sure that
the lance is in a secure position. Grease quick release nipple regularly using
acid-free grease.
The plug coupling must not be actuated/handled during operation! High risk of
injury!
Prior to insertion, check plug coupling connection of lance for cleanliness
(sand, dirt ..) and use clear water to clean, if necessary. Impurities may
damage the sealing in the plug coupling.
When using high-pressure hose extensions take care that the max. length of 20
m is not exceeded!
Accessories may only be connected to a Kränzle-approved trigger gun with
safety catch.
21
Putting into operation
8. Check water inlet filter for cleanliness prior to putting the high-
pressure cleaner into operation. Manually unscrew plug-in coupling. Take out
the water inlet filter using needle nose pliers and thoroughly rinse it with
clear water and clean it with the other parts. If the sieve is dirty, water
can not get through and pressure will not build up.
Check the water inlet sieve for damage. Do not operate the high-pressure
cleaner without or with a damaged filter.
9. Connect water hose to water inlet (minimum requirements; 5 m hose length,
cross-section ¾”, 10 bar). The high-pressure cleaner may be connected to a
water mains (1-10 bar pre-pressure) with either cold or hot water (up to 60
°C).
Be careful when using hot water! When running your high-pressure cleaner with
hot water of 60 °C raised temperatures occur. Do not touch the metal parts of
the high-pressure cleaner without safety gloves!
10. Each time check oil level at the oil dipstick prior to putting the high
pressure cleaner into operation. (Take care that cleaner is in horizontal
position!) Oil level must reach until the upper edge of marking “OK”.
22
Putting into operation
11. Connect to circuit (see technical data).
Do not touch the mains plug or any live parts with wet or moist hands.
12. Switch on high-pressure cleaner with opened safety trigger gun. Bleeding
of the high-pressure cleaner: Pull and release trigger of safety trigger gun
several times. Start cleaning task.
13. When using the dirtkiller lance make sure that lance points downward when
starting.
14. Adjust operating pressureinfinitely using the rotary handle. The maximum
pressure is factory-set.
15. The K 1152-series units are equipped with a support for the safety
trigger gun with lance during breaks. Operate high-pressure cleaner in
horizontal position.
23
Applying additives
Suction of additives
For K 1152-series a built-in injector provides the facility to suck in
additives. By pushing the Vario-Jet lance to the front the high-pressure
cleaner is adjusted to low pressure and a vaccum is build up in the injector.
Thus the additives can be sucked in via the connected suction hose with
filter.
1. Place chemicals filter into container with additives
2. To reach the low pressure push Vario nozzle to the front so that the
injector can suck in the additives.
3. When pushing the Vario nozzle backwards, chemicals supply is automatically
stopped, high-pressure cleaner changes in high-pressure mode. Let additives
take effect and then spray off with high-pressure.
The additive must reveal a neutral pH value of 7-9. This machine has been
designed for use of cleaning agents supplied or specifically recommended by
the manufacturer. The use of other cleaning agents or chemicals may impair the
safety of the machine. Observe and comply with relevant regulations, e.g.
directives governing protective equipment, waste-water regulations, etc.
Attention solvents! Never suck in liquids containing solvents like varnish
solvents, petrol, oil or similar liquids! Seals inside the high-pressure
cleaner are no resistant against solvents! The spray mist of solvents is
highly inflammable, explosive and poisonous.
24
Taking out of operation
1. Switch off the high-pressure cleaner 2. Cut off the water supply 3. Open
the safety trigger gun catch briefly until the pressure is released 4. Apply
safety catch on the trigger gun 5. Remove high-pressure hose and safety
trigger gun 6. Emptying high-pressure pump: Hold high-pressure hose and switch
motor on until water jet stops escaping at the outlet. 7. Pull the plug from
the socket 8. Clean high-pressure hose and wind up without loops 9. Clean and
wind up the power supply cable 10. Clean the water inlet sieve 11. Store high-
pressure cleaners in frost-free rooms in winter
Frost protection
For protecting the high-pressure cleaner against frost please empty it
completely. Separate high-pressure cleaner from water supply and switch it on.
By opening the trigger gun the high-pressure pump presses water out of the
high-pressure cleaner. However, do not allow the device to operate without
water for more than one minute.
Due to their small base, the compact and mobile Kränzle high-pressure cleaners
are easy to store.
25
Small repairs – do it yourself
Problem
No water from nozzle although the high-pressure cleaner is running. The
stainless steel pressure gauge shows full pressure.
Cause
Most likely the nozzle is blocked.
The stainless steel pressure gauge shows full pressure, but from the nozzle
comes only little water or no water at all.
(Inside the stainless steel pressure gauge is no water but a filling with
glycerin to damp the vibration of the pointer.)
Proceeding: Switch off the high-pressure cleaner. Pull plug from the socket.
Operate safety trigger gun catch several times to decrease the pressure.
Remove safety trigger gun and lance first, then rinse high-pressure hose to
remove possible soiling.
Check water inlet filter for soiling.
If the problem still exists, take wire (paper clip) and push through nozzle
opening. If this procedure is not successful, the nozzle has to be replaced.
Pull plug from socket prior to starting any repair work!
26
Small repairs – do it yourself
Problem
Irregular jet from nozzle. The stainless steel pressure gauge shows low
pressure.
Cause
Most likely the valves are soiled or sticky.
The stainless steel pressure gauge shows low pressure despite fully turned up
pressure regulation. The water from the lance comes in squirts. The high-
pressure hose vibrates.
(Inside the stainless steel pressure gauge is no water but a filling with
glycerin to damp the vibration of the pointer.) Proceeding: Unscrew all 6
valves, one after the other (hexagonal brass screws, 3 in a row, vertically
and horizontally)
Take out valve body and O-ring by means of needle nose pliers. Check O-ring
for damage. In case of a damage the O-ring has to be replaced.
Take a wire (paper clip) and clean valves under running water.
Do not forget the O-ring during reassembly!
27
Small repairs – do it yourself
Problem
After closing the safety trigger gun the high-pressure cleaner keeps switching
on and off. The stainless steel pressure gauge continuously displays full
pressure.
Possible cause No. 1
Leckage.
Having closed the trigger gun with safety catch, the high-pressure cleaner
must shut down and the stainless steel pressure gauge must show ,,0″ bar. If
not shut down and the stainless steel pressure gauge continuously shows full
pressure, this could be due to leakage at the high-pressure pump, at the
pressure switch, at the high-pressure hose or at the trigger gun with safety
catch. Proceeding: Check connections from the high-pressure cleaner to the
high-pressure hose and from the high-pressure hose to the safety trigger gun
and also the connection between lance and safety trigger gun for tightness.
Switch off the cleaner. Shortly press the trigger of the trigger gun with
safety catch to decrease the pressure. Remove high-pressure hose, trigger gun
with safety catch and lance and check the O-rings. If the O-rings are damaged
they have to be replaced.
In case of a leakage there is no guarantee for possible consequential damages.
28
Small repairs – do it yourself
Problem
After closing the safety trigger gun the high-pressure cleaner keeps switching
on and off. The stainless steel pressure gauge continuously displays full
pressure.
Possible cause No. 2
The non-return valve is defective. Proceeding: Switch off the high-pressure
cleaner and pull plug from socket. Stop water supply. Operate safety trigger
gun catch several times to decrease the pressure. Unscrew pump outlet.
Remove check body and check O-Ring for soiling or damage. Also check seal seat
inside pump housing for soiling or damage.
If sealing rings are defective replace O-rings at once.
There is no guarantee if the high-pressure pump is damaged by defective
O-rings due to air induction or lack of water (cavitation).
29
Kränzle accessories
Rotating washing brush Stainless steel pipe 500 mm Brush head 180 mm Nozzle
size 3.2 mm With anti-twist protection With plug-in nipple Ord. no.: 410506
Floor washer Round Cleaner UFO
300 mm Nozzle system 045 With wheels With plug-in nipple
Ord. no.: 41881
Underbody lance Stainless steel pipe 1000 mm Nozzle system 4007 With anti-
twist protection With plug-in nipple Ord. no.: 410755
The high-pressure cleaner accessories are safety components! Any warranty will
be void if parts not authorised by Kränzle are used.
30
Kränzle accessories
Foam injector 1 litre, with container Dosage in 5 levels With plug-in nipple
Ord. no.: 135303
Splash guard L: 280 mm x W: 190 mm For all washing lances Ord. no.: 132600
Pipe cleaning hose with nozzle
In different lengths Nozzle system KN 055 With plug-in nipple
10 m Ord. no.: 12550 15 m Ord. no.: 125501 20 m Ord. no.: 125502 25 m Ord.
no.: 125503 30 m Ord. no.: 125504
Please indicate the technical data of the high-pressure cleaner (device type)
when placing your order.
31
EU Declaration of Conformity
We here by declare that the design of K 1152 TS the high-pressure cleaners: K 1152 TST
Nominal flow: 600 l/h
technical specifications available Fa. Josef Kränzle GmbH & Co. KG from: Manfred Bauer Rudolf-Diesel-Str. 20, 89257 Illertissen
comply with the following guidelines and their amendments for high-pressure cleaners:
Machinery Directive 2006/42/EC EMC Directive 2014/30/EU ROHS Directive 2011/65/EU Outdoor Directive 2000/14/EC
Noise pressure level, typical: 91,7 dB (A) Noise pressure level, guaranteed: 93 dB (A)
Applied conformity assessment Annex V, Outdoor Directive procedure: 2000/14/EC
Applied specifications and standards:
EN 603351:2012/A13:2017 EN 60335279:2012 EN 62233: 2008 EN 550141: 2006+A1: 2009+A2: 2011 EN 550142: 2015 EN 6100032: 2014 EN 6100033: 2013
Josef Kränzle GmbH & Co. KG Rudolf-Diesel-Straße 20 89257 Illertissen
(Germany)
Illertissen, 2019-04-05
Ludwig Kränzle (Managing director)
32
Warranty
The warranty obligation of Josef Kränzle GmbH & Co. KG towards the dealer from
whom you have purchased this Kränzle high-pressure cleaner (= product) applies
to material faults only such as material and manufacturing defects.
Defects attributable to long and frequent use of the product, typically
arising due to the age of the high-pressure cleaner and intensity of its use
are defined as normal wear in respect of product components. Purchaser’s
rights to assert claims for such defects are ruled out. Parts subject to wear
include in particular the pressure gauge, nozzle, valves, sleeves, high-
pressure hose and spray equipment.
The product is to be operated in conformity with this operating manual. The
operating manual is deemed to be part of the warranty provisions.
Any changes made to the safety devices of the product or instances of
maloperation such as exceeding the temperature and speed limits,
undervoltage, insufficient water supply and sewage water, or failure to use
the product for the intended purpose may result in damage occurring to the
product. Such damage is not deemed to constitute any material defect.
Should the use of accessories or spares other than original Kränzle component
parts und original Kränzle replacement parts be the cause of defects on our
product, this may lead to all warranty claims becoming null and void. Only the
use of original Kränzle replacement parts matching the relevant Kränzle high-
pressure cleaner provides adequate assurance for safe and trouble-free
operation of the Kränzle high-pressure cleaner.
With regard to legal warranty claims, the limitation periods of the respective
countries shall apply.
Where warranty claims apply to any other defects, please contact your local
dealer, presenting the accessories together with your purchase receipt, or the
nearest authorised service centre. This can also be found on the internet
under www.kraenzle.com.
33
Inspection reports
High-pressure cleaners for industrial use have to be checked by an expert every 12 months! Inspection report on annually carried out Labour Safety Inspection (UVV) according to the Guidelines for Liquid Spray Equipment. (This inspection sheet serves as proof for the completion of the retest and must be kept carefully!)
Kränzle-test seals: Item no.: UVV200106
Owner: ……………………………………………………………………… Address: …………………………………………………………………….
………………………………………………………………………………………..
Type: …………………………………………………………………………… Serial no.: ………………………………………………………………….. Repair order no.: …………………………………………………….
Scope of inspection
Type plate (on hand) Operating manual (on hand) Protective covering,
Protective device Pressure line (tightness) Stainless steel pressure gauge
(function) Float valve (tightness) Spraying device (marking) High-pressure
hose / connector (damage, marking) Safety valve opens at 10 % / 20 % exceeding
Power supply cable (damage) Protective conductor (connected) On / Off switch
Used chemicals Allowed chemicals
o.k. yes no
repaired
Inspection data
High-pressure nozzle Operating pressure ………………bar Switch off pressure
……………..bar protective conductor resistance not exceeded / value Insulation
Leakage current Safety trigger gun locked
determined value set value
Inspection result (check)
The high-pressure cleaner was checked by an expert according to the Guidelines
for Liquid Spray Equipment, the defects found have been rectified so that the
Labour Safety can be confirmed.
The high-pressure cleaner was checked by an expert according to the Guidelines
for Liquid Spray Equipment. The Labour Safety cannot be confirmed unless the
defects found are rectified by repair or replacement of the faulty parts.
The next retest according to the Guidelines for Liquid Spray Equipment has to
be carried out by: Month …………………………………………………………. Year
……………………………………………………………..
Place, Date ……………………………………………………………….. Signature …………………………………………………………………….
34
Inspection reports
High-pressure cleaners for industrial use have to be checked by an expert every 12 months! Inspection report on annually carried out Labour Safety Inspection (UVV) according to the Guidelines for Liquid Spray Equipment. (This inspection sheet serves as proof for the completion of the retest and must be kept carefully!)
Kränzle-test seals: Item no.: UVV200106
Owner: ……………………………………………………………………… Address: …………………………………………………………………….
………………………………………………………………………………………..
Type: …………………………………………………………………………… Serial no.: ………………………………………………………………….. Repair order no.: …………………………………………………….
Scope of inspection
Type plate (on hand) Operating manual (on hand) Protective covering,
Protective device Pressure line (tightness) Stainless steel pressure gauge
(function) Float valve (tightness) Spraying device (marking) High-pressure
hose / connector (damage, marking) Safety valve opens at 10 % / 20 % exceeding
Power supply cable (damage) Protective conductor (connected) On / Off switch
Used chemicals Allowed chemicals
o.k. yes no
repaired
Inspection data
High-pressure nozzle Operating pressure ………………bar Switch off pressure
……………..bar protective conductor resistance not exceeded / value Insulation
Leakage current Safety trigger gun locked
determined value set value
Inspection result (check)
The high-pressure cleaner was checked by an expert according to the Guidelines
for Liquid Spray Equipment, the defects found have been rectified so that the
Labour Safety can be confirmed.
The high-pressure cleaner was checked by an expert according to the Guidelines
for Liquid Spray Equipment. The Labour Safety cannot be confirmed unless the
defects found are rectified by repair or replacement of the faulty parts.
The next retest according to the Guidelines for Liquid Spray Equipment has to
be carried out by: Month …………………………………………………………. Year
……………………………………………………………..
Place, Date ……………………………………………………………….. Signature …………………………………………………………………….
35
© Kränzle 09.02.2021 / Ord. no.: 307920 / Subject to technical modifications and errors.
Josef Kränzle GmbH & Co. KG Rudolf-Diesel-Straße 20 89257 Illertissen
(Germany)
sales@kraenzle.com
Made in Germany
www.kraenzle.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>