MeacoFan 1056P Air Circulator Instruction Manual
- June 5, 2024
- MEACO
Table of Contents
MeacoFan 1056P Air Circulator
SAFETY INFORMATION
This air circulator must not be used in rooms under the following conditions:
- Potentially explosive atmosphere
- Aggressive atmospheres
- Featuring a high concentration of solvents
- An extremely high ratio of dust
- Commercial environments
Magnets: The air circulator and the remote control both contain magnets. Please note the following: Pacemakers and defibrillators may be affected by magnets. If this affects you then please do not put the remote control in a pocket and warn anyone who is likely to use the air circulator or the remote that it has a magnet. Credit cards and data cards can also be affected by magnets and should not be placed near to the air circulator or the fan.
Keep Children Away: Do not allow children to play with or around this unit, which could result in injury. Be sure the unit is inaccessible to children when not attended. This appliance is not intended for use by person (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Keep Unit Grounded: Always operate the unit with a grounding plug and a grounded electrical outlet. A grounding plug is an essential safety feature that helps reduce the risk of shock or fire.
Protect Power Cord from Damage : Never operate a unit with a damaged power cord, as this may lead to electrical or fire hazards. If the power supply cord is damaged, it must be replaced by a cord of the same type and amperage rating.
Extension Cords: Extension cords must be grounded and able to deliver the appropriate voltages to the unit.
H andle with Care: Do not drop, throw or crash the air circulator. Rough treatment can damage the components or wiring and create a hazardous condition.
Run on Stable Surface: Always operate the unit on a stable, level surface, for example the floor or a strong counter, so that the air circulator cannot fall and cause injury.
Keep Out of Water: Never operate the unit in pooled or standing water, as this may create a risk of injury from electrical shock. Do not store or operate outdoors. If electrical wiring or components become wet, thoroughly dry them before using the unit. If in doubt do not use the air circulator and consult a qualified electrician or a Meaco approved engineer.
Keep Air Intakes Clear: Do not clog or block the air intakes by placing the air circulator too close to curtains, walls or anything that will restrict the air inlet. This may cause the unit to overheat and result in a fire or electrical hazard.
Keep Electrical Components Dry: Never allow water inside the air
circulator’s electrical components. If these areas become wet for any reason,
thoroughly dry them before using the air circulator. If in doubt, do not use
the air circulator and consult a qualified electrician or a Meaco approved
engineer.
The operator must make the operating instruction available for the user and
make sure that the user does understand the manual.
WIRING INSTRUCTIONS
Should it be necessary to change the plug, please note the wires in the mains
lead are coloured in accordance with the following code:
BLUE – NEUTRAL
BROWN – LIVE
GREEN AND YELLOW – EARTH
As the colours of the wires in the mains lead of this appliance may not
correspond with the coloured markings identifying the terminals in your plug,
proceed as follows:
- The BLUE wire is the NEUTRAL and must be connected to the terminal which is marked with the letter N or coloured BLACK.
- The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED.
- The GREEN/YELLOW is the EARTH and must be connected to the terminal which is marked with the letter E or coloured GREEN or GREEN/YELLOW.
- Always ensure that the cord grip is positioned and fastened correctly.
- Only ever use the same fuse as fitted in the original product, if in doubt please contact Meaco first, or a qualified electrician.
Example wiring for a Standard British Plug:
Please note: The Earth Terminal is marked with the letter E or Earth Symbol
GENERAL ADVICE
- Before putting your air circulator into operation for the first time, the instruction manual should be studied carefully.
- After receiving the air circulator, you should check the unit for any transport damage. In case of damage, you should inform the sender immediately.
- Keep the packaging for the air circulator in a safe place in order to be able to despatch the unit safely if it requires a service. In order to save space, you can simply cut through the adhesive tape using a knife and fold the cardboard box.
PRODUCT IDENTIFICATION
- Magnetic remote-control holder
- Front guard
- Spinner
- Fan blades
- Handle*
- Rear guard
- Fan motor
- Motor bracket
- Support bracket
- Pedestal release button
- Pedestal
- Power cord
- Base
- Remote control**
The handle is made from artificial materials and does not contain any animal products. ** The remote control is supplied with a CR2025 DC3v battery. Please remove the tab from the battery before use.
SET UP
The MeacoFan 1056P is a pedestal air circulator which can be used at various
adjustable heights.
In order to adjust the height of the air circulator press the release button
on the back of the pedestal. Push the release button and lift the air
circulator via the support bracket. The air circulator will click into place
at the chosen height. To reduce the height of the air circulator, reverse the
process. Push the release button and press down on the support bracket.
CONTROL PANEL
Please note all the buttons are touch sensitive and bleep when pressed. The buttons need to be pressed quickly, do not hold your finger on the button for longer than one second (unless when turning the air circulator ON/OFF, see below). Do not operate the controls on the base of the air circulator with your feet.
POWER BUTTON
When plugged in the air circulator will bleep once and display the room
temperature on the display, this is standby mode. To turn the air circulator
on put your finger on the power button for two seconds. The air circulator
will bleep and start to operate. To turn the air circulator off, put your
finger on the power button again for two seconds, you will hear a longer bleep
and the air circulator will slow down and stop.
MODE BUTTON
Press the mode button to move through the four modes: normal, natural, sleep
and ECO.
Normal Mode: This is the default setting on the air circulator. The fan
speed can be adjusted between 1 and 12. The airflow is constant on each fan
speed.
Natural Mode: Press the mode button once to reach natural mode – the
symbol to the left will appear on the display. The fan speed can be adjusted
between 1 and 12. The airflow will alternate between weak and strong in order
to replicate a natural breeze.
Sleep Mode: Press the mode button twice to reach sleep mode – the symbol
to the left will appear on the display. The fan speed will decrease by one
level every 30 minutes. When fan speed 1 has been reached, the fan will
continue to run until it is manually turned off.
ECO Mode: Press the mode button three times to reach ECO mode – the room
temperature will appear on the display. In ECO mode the fan speed will
automatically change as per the table on the following page.
ECO Mode
Room temperature | Fan speed |
---|---|
<23°C | 2 |
23 to 25°C | 4 |
25 to 27°C | 6 |
27 to 29°C | 8 |
29 to 31°C | 9 |
31 to 33°C | 10 |
>33°C | 12 |
SPEED BUTTON
Press the speed button to adjust the air flow fan speed. There are 12 fan
speeds available. As long as the air circulator remains plugged in, the air
circulator will remember the last fan speed used. The speed can be adjusted on
the control panel or via the remote control.
VERTICAL AND HORIZONTAL OSCILLATION BUTTONS (OSC)
Press the oscillation buttons to start and stop the sideways oscillation left
and right or up and down. Press the button once to turn the oscillation on and
press the button again to stop the motion, in doing so you can fix the
direction of the air circulator.
TIMER BUTTON
When the air circulator is in standby mode use the timer button to set an
interval, in one-hour segments, between 1 and 12 hours after which the air
circulator will turn ON. Once you have reached the desired number of hours on
the display the number will flash four times and then set.
When the air circulator is turned on and running, use the timer button to set
an interval, in one-hour segments, between 1 and 12 hours after which the air
circulator will turn OFF. Once you have reached the desired number of hours on
the display the number will flash four times and then set.
To turn the timer off, press the timer button until 00 is displayed.
REMOTE CONTROL
The following functions are only available via the remote control. All other buttons on the remote-control work in the same way as the control panel (see pages 6 and 7). The remote control has a range of approximately three metres. Before using the remote control, remove the plastic tab.
LIGHT BUTTON
Press the light button to turn the lights on the display ON/OFF.
INCREASE FAN SPEED
Press the increase fan speed button to increase the air flow fan speed between 1 and 12.
DECREASE FAN SPEED
Press the decrease fan speed button to decrease the air flow fan speed between 12 and 1.
PRE-ON TIMER
Press the pre-on timer button to set an interval, in one-hour segments, between 1 and 12 hours after which the fan will turn ON. This can only be used when the air circulator is in standby mode.
PRE-OFF TIMER
Press the pre-off timer button to set an interval, in one-hour segments, between 1 and 12 hours after which the fan will turn OFF. This can only be used when the air circulator is on and running.
ELECTRICAL CONNECTIONS AND OPERATING CONDITIONS
This air circulator was designed to operate in a 220-240V / 50Hz electrical
installation. Make sure that the electric sockets are connected to earth and
that all safety precautions are taken. This air circulator can be operated
within an ambient temperature range from +5°C to +40°C and with a non-
condensing relative humidity.
SPECIFICATIONS
Operating conditions
|
+5°C to +40°C
---|---
Humidity operating range
|
Non-condensing
Fan motor type
|
DC
Maximum air flow
|
1653 cubic metres per hour
*Maximum air velocity (c)
|
4m/sec
*Rated voltage and frequency
|
220 – 240V / 50Hz
Power consumption
|
6 to 24 watts
*Standby power consumption (PSB)
|
<0.5 watts
Oscillation swing angles
|
60° vertically and 80° horizontally
*Fan sound power level (LWA)
|
20 to 60dB(A)
*Service value (SV)
|
1.2 (m³/min)/watts
*Fan power input (P)
|
23 watts
*Maximum fan flow rate (F)
|
27.56m³/min
Dimensions (HWD)
|
820-955 x 320 x 339mm
Nett weight
|
4.7 Kgs
Measurement Standard for Service Value (all items): 2009/125/EC, (EU) No 206/2012 + (EU) No 2016/2282, IEC 60879:1986, EN 60704-1:2010 + A11:2012, EN 60704-2-7:1998.
CLEANING AND MAINTENANCE
Always turn the air circulator off and unplug it from the socket before
cleaning.
Use a soft dry cloth to clean the external and internal parts of the air
circulator. Do not allow the air circulator to get wet. In order to access the
fan blades, follow the steps below:
-
Using a screwdriver, unscrew the two small screws at the top back of the air circulator. They are located directly below each end of the
-
Squeeze the two tabs to the left and right of the screws and pull At the front of the fan blades there is a locking cap – unscrew the cap in a clockwise motion to remove the fan blades.
-
Clean the fan blades and the internal part of the fan using a soft dry cloth. Reverse the procedure to put the air circulator back together. Make sure the locking cap is tightened securely.
REPLACING THE REMOTE-CONTROL BATTERY
If the remote control fails to work whilst close to the fan, the battery will need replacing. The battery is a CR2025 and can be replaced following the steps in the diagram below.
STORAGE
When storing the air circulator use the cable compartment at the back of the
air circulator to store the mains cable. The cable compartment cover may be
stiff to remove at first – use the small lever at the top to pull it away from
the air circulator.
We recommend storing the fan its plastic bag or original box to protect the
air circulator from dust.
Remember the air circulator can also be used in winter to help distribute warm
air more effectively within a room.
TROUBLESHOOTING
PROBLEM | CAUSE | SOLUTION |
---|
The display shows ‘00’ or ‘99’
|
There is a problem with the circuit
|
Please contact Meaco
The air circulator does not oscillate
|
The MPCB needs resetting
|
Unplug the air circulator from the mains for 40 minutes
Increased noise level
|
The fan blades are dirty
|
Clean the fan blades (see page 10)
The fan blades or fan motor is loose
|
Tighten the locking cap (see page 10)
There is a fault with the fan motor
|
Please contact Meaco
The motor can be heard on the lower fan speeds
|
As the air circulator is so quiet it is expected to hear the motor on the lower fan speeds. As the fan speed increases, the noise of the motor will reduce
|
This is not a fault and is normal
The air circulator does not start up
|
The air circulator is in standby mode
|
Press the power button again
The air circulator is making a clicking noise
|
The air circulator needs lubricating
|
Run the air circulator on the highest fan speed for 4 hours
The remote does not work
|
The battery needs replacing
|
Replace the battery (see page 11)
The remote is being used more than 3m away from the fan
|
Use the remote closer to the fan and make sure it is pointing directly at the fan base
The fan speed increases and decreases randomly
|
This is not a fault – the air circulator is in natural mode
|
Change the air circulator mode by pressing the mode button (see page 6)