Hornady 98215 Rapid Safe Night Guard Owner’s Manual
- June 5, 2024
- Hornady
Table of Contents
- READ THIS FIRST
- Important Information
- Items included with your RAPiD® Safe
- Open Safe with Key
- AC Power
- Keypad Tones On/Off
- Batteries
- Battery Power Mode
- How to Program Your RFID Tags
- To program these tags:
- How to Program Your Key Code
- Closing the Night Guard
- USB Charging Ports
- How to Program Clock
- Securing Your Safe
- Frequently Asked Questions
- RAPiD® Safe Limited Warranty
- Product Registration and Service
- Product Serial Number and Key Number Reference
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
98215 Rapid Safe Night Guard
Owner’s Manual
Item
No. 98215
Instructional videos for Hornady Security® products can be found at
hornady.com. The search item number or product description in the search bar.
READ THIS FIRST
Warning: NEVER store a loaded firearm in the Hornady Security® RAPiD® Safe Night Guard® under any circumstances. The risks associated with the storage of a loaded firearm include, but are not limited to, unintentional discharge upon insertion or removal of the firearm. Unintentional discharge may result in bullet and safe fragments dispersing in multiple directions, which may cause serious injury or death. Hornady Security® is not liable for any misuse of the RAPiD® Safe.
Warning: No safe is entirely secure. The RAPiD® Safe is only as secure as your maintenance of the keys, code, and RFID tags. You are solely responsible for maintaining your keys, code and RFID tags. Keep your keys and RFID tags in a secure location at all times. Store your RAPiD® Safe in a secure location away from your keys and RFID tags. Hornady Security® is not liable for unauthorized access, including damage to, loss of property, or personal injury. Again, NEVER store a loaded firearm in your Hornady® RAPiD® Safe, as this may result in unauthorized access to the loaded firearm.
Warning: Except as expressly provided in the RAPiD® Safe Limited Warranty, Hornady Security® is not liable for any expense or damage associated with your inability to open the RAPiD® Safe. Electronic systems may fail. Verify that the keys furnished operate the lock. Keep your keys in a secure location at all times. For your security, Hornady Security® WILL NOT send replacement keys.
Warning: Hornady Security® is not liable for any loss, theft, or damage to personal property. The RAPiD® Safe is not intended to protect the contents from fire, water, humidity, or other environmental conditions. Do not, under any circumstances, return the RAPiD® Safe to Hornady Security® with any personal property inside.
Important Information
- RFID Tag refers to the chip in any of the RFID “keys” included with the RAPiD® Safe (RFID watchband tag, key fob or decals). You may also purchase additional RFID tags.
- For trouble-free operation of your RAPiD® Safe, please read and understand all instructions before use.
- Questions? Call our tech line at800-338-3220.
- Never store loaded firearms in the RAPiD® Safe. Follow local laws for firearm storage.
Items included with your RAPiD® Safe
- RAPiD® Safe Night Guard®
- Wall Power Supply
- One (1) RFID Watchband Tag (No. 98159)
- Two (2) RFID Adhesive Decals (No. 98168)
- One (1) RFID Key Fob Tag (No. 98161)
- Two (2) Circular Barrel Keys
- Security Cable (No. 98169)
RAPiD® Safe Night Guard®
Item No: 98215
Exterior: 12″W x 10.5″D x 3″H
Interior: 9.2″W x 6.9″D x 2.2″H
Weight: 18 lbs.
Input Power: 12VDC 2.0A or four (4) AAA batteries (not included)
Output Power: 5VDC 2.0A
Not Pictured:
- RAPiD® Safe Night Guard®
- Owner’s Manual
- Warranty Card
U.S. Patent No. 9,530,266
U.S. Patent No. 10,233,687
U.S. Design Patent No. D786,047
RAPiD® Safe Setup and Operation
Congratulations on purchasing the technologically advanced RAPiD® Safe Night
Guard®.
You have taken a significant step in securing the safety of your firearms.
To achieve the best experience with your RAPiD® Safe, please read all
instructions carefully, and understand its operation.
After the RAPiD®Safe has been taken out of the box, please check to be sure both circular barrel keys fit and unlock your RAPiD® Safe. Contact Hornady® at800-338-3220 if the keys do not work. Store keys in a secure location outside the safe.
Open Safe with Key
The RAPiD® Safe includes two barrel keys that will open the safe when inserted
into the lock on the back panel of the RAPiD® Safe and turned clockwise.
NOTE: Store keys in a secure location outside of the safe.
AC Power
The RAPiD® Safe is designed to be powered by either the AC power supply or
four AAA batteries.
To connect the AC power supply, plug the power cord into the jack on the back
of the safe.
Keypad Tones On/Off
With the door open and unlocked, press and hold the “H” button on the keypad for 5 seconds until the light turns off to toggle sound on and off.
Batteries
To install batteries, press the lower-left corner of the battery cover on the
front of the safe. Insert four (4) high-quality AAA batteries according to the
diagram. Replace all batteries at the same time.
NOTE: The battery symbol near the clock display will illuminate red when
the batteries are weak. Plugin the safe or replace batteries immediately.
Battery Power Mode
When the RAPiD® Safe is unplugged and is operating on battery power, you must
press any button on the keypad to activate the reader.
Pressing any button on the keypad causes the system to go from battery saving
mode to ready status.
For example: To open your safe with an RFID tag, while the system is
running on battery power, first press any button on the keypad to bring it to
ready status.
Place your RFID tag within 1″ of the center of the clock display to open the
safe.
Note : When in Battery Power Mode, the clock display will turn off after
approximately 10 seconds to conserve batter power. Press any button to
illuminate the clock display.
How to Program Your RFID Tags
You’re RAPiD® The safe includes three (3) styles of RFID tags, including:
- 1 Watchband Tag
- 1 Key Fob
- 2 Decals
*Additional styles can be purchased separately.
To program these tags:
-
Open the RAPiD Safe with either the key or a previously programmed RFID tag or key code. The safe does not ship with preprogrammed RFID tags. An RFID tag must be programmed to work with this safe.
-
Locate the red program button inside the drawer on the back wall. Press and release the button to begin programming an RFID tag. The first available program location will begin to blink.
-
Hold the RFID tag within 1″ of the illuminated RFID reader area (clock display) on the drawer front If the programming was successful, the safe should beep two times and the available slot should go from blinking to solid red for approximately ten seconds.
NOTE: If the user attempts to program an RFID tag that is already stored in the safe it will beep three times and the RFID tag will not be programmed into the duplicate slot. The RFID tag can only be programmed into one location. -
Verify the RFID tag is programmed by holding the tag over the clock display with the drawer open. The motor should cycle after each scan.
-
If the RFID tag is not programmed, the program function will time out after ten seconds and the safe will return to normal operation. If multiple attempts to program an RFID tag fails, please contact Hornady® at 800-338-3220.
-
One to five RFID tags can be programmed into the safe.
NOTE: Due to potential interference from the body (attenuation), the RFID watchband tag should be worn on the outside or bottom of the wrist and may need to be brought within 1-inch of the reader to activate the safe. The RFID reader will likely not read through the wrist.
NOTE: The RFID decal can be placed on a variety of objects. However,
metal surfaces may cause interference and reduce the read distance. The
integrated metal housing on some cell phones combined with potential
interference from other wireless signals such as Bluetooth, NFC, etc., may
reduce the read distance of the RFID decal.
Before adhering the RFID decal to a mobile phone, we recommend trying
different locations on the back of the device to find the optimum read
distance. Placing the decal on the outside of an accessory cover will also
improve the read distance, but may cause excessive wear, resulting in a
shortened life of the decal. When placing
the decal on the inside of an accessory cover, DO NOT face it toward the
mobile phone. The decal must face outward (away from the phone) to work
optimally.
Before placing the RAPiD Safe into service, verify the decal works properly
under various conditions (i.e. the wireless apps on your mobile phone are on).
How to Remove All Tags From Safe
-
Open the RAPiD® Safe with either the key, a previously programmed RFID tag, or key code. Locate the red program button. Press and hold the button for five seconds to erase all previously programmed tags.
All five red LEDs will begin to blink in sequence. The safe does not allow individual tags to be removed. They must all be erased at one time. The intended RFID tags can then be reprogrammed with the “How to Program Your RFID Tags” section.
NOTE: To abort the erase procedure, press the “H” button on the drawer of the safe or do not touch anything and the erase procedure will automatically abort after 10 seconds and return to normal operation. Test RFID tags and the key code to confirm they are operational.
-
To confirm erasing procedure, press and release the program button again.
All five LEDs will blink three times to visually confirm all RFID tags have been removed. The RFID tags will no longer work until they are reprogrammed with the instructions in the “How to Program Your RFID Tags” section.
How to Program Your Key Code
A single user-defined 4 to 6-digit code can be entered into the RAPiD® Safe Night Guard®.
- Open the RAPiD Safe with either the key, a previously programmed RFID tag or key code. The safe ships with a default code and should be reprogrammed before first use.
- Locate the red program button to begin programming your key code. The first available tag location will begin to blink to indicate program mode.
- With the drawer open, enter a 4 to 6-digit code on the keypad. Press the “H” after entering your code. Verify your code is correct by re-entering your code and pressing “H”. The motor should cycle.
- Your key code can now be used to open the safe.
NOTE: Only one keycode can be entered into the safe. If a second code is entered, it will override the previous code. **A total of five RFID tags and one key code can be entered into the safe.
Closing the Night Guard
The safe has a latch closure sensor that will illuminate the LED in the keypad
when the drawer is closed.
Green – Latch has fully closed.
Blinking Red – Latch has NOT fully closed.
To close the safe, press the drawer in until the latch clicks. Verify green
light appears on the keypad.
USB Charging Ports
The RAPiD® Safe includes two USB Type-A charging ports on the back of the
safe.
When the RAPiD® Safe is plugged into AC power with the included power supply,
the two charging ports can be used to power common electronics.
Total Output: 5VDC 2.0A
How to Program Clock
To program the clock display, press and hold the TIME button until the hour
digit begins to blink (approximately 5 seconds). Press the UP or DOWN arrow
buttons to adjust the hour.
Press the TIME button again to switch to minutes and adjust with the UP and
DOWN arrow buttons. Pressing the TIME button again will finish setting the
time.
To adjust the brightness of the clock display, press the UP and DOWN arrow
buttons until the desired brightness is reached.
The clock display can be turned off by pressing the DOWN arrow button until
the clock display is off.
Note: The clock will stay illuminated when the safe is plugged into a
wall outlet.
When in Battery Power Mode, a clock display will turn off after approximately
10 seconds to conserve battery power.
Securing Your Safe
|
---|---
To maintain the security of the safe either use the included security cable or
bolt the safe to a secure structure.
Using the Security Cable Wrap the security cable around a secure object and
place the ferrule end through the loop in the cable.
With the drawer open, snap the narrowest diameter of the ferrule into the back
of the safe by gently pushing the ferrule end against the spring plate and
sliding the ferrule down. As the drawer closes, it presses against the spring
plate and locks the ferrule in place.
To remove the security cable, open the safe and press the pin above the
ferrule while lifting the ferrule.
Bolting Down the Safe
Remove the drawer by gently pulling it out while pressing the plastic tab on
the left side up and the tab on the right side down. Note the small electrical
wire that runs from the back of the safe to the back of the drawer.
CAUTION: Do not pull or pinch the cable as it may damage the wiring.
Mark and pre-drill holes before installing the appropriate fasteners for your application.
Reinstall the drawer by aligning the drawer slides with the slides on the housing. Before pushing the drawer into the housing, verify that the electrical wire connection is safely inside the housing and will not be pinched as the drawer is closed.
Frequently Asked Questions
I’ve lost my keys. Can I get a replacement?
Contact Hornady Security® at
800-338-3220 and one of our technicians
will assist you.
Where can I find the serial number?
The serial number is located on the back of the safe. Prior to mounting the
safe, record the serial number for future reference.
How long should the batteries last?
Quality batteries should last approximately 12 months, depending on use.
How do I return my RAPiD®
Safe for warranty work?
Call Hornady® at 800-338-3220 and one
of our technicians will assist you.
Why isn’t my RFID watchband tag, key fob, or decals opening the safe?
- Be sure the RFID tag is programmed to your safe. The RAPiD® Safe allows five (5) RFID tags to be programmed for use.
- Check the power source. If the unit is plugged into an electrical outlet, the green LED light should be on. If the unit is on battery power, press the button on the top of the safe to bring the system to ready before placing the RFID tag on the reader.
RAPiD® Safe Limited Warranty
Hornady Security® warrants the RAPiD® Safe will, in normal use and service, be
free from defects in workmanship or materials for one (1) year from date of
purchase.
This Limited Warranty does not cover any of the following:
(a) Damage, deterioration, or malfunction resulting from accident, negligence,
misuse, improper installation, or lack of maintenance;
(b) Any defects not discovered and reported to Hornady Security® during the
one (1) year warranty period;
(c) Usual and customary deterioration or wear resulting from normal use.
This Limited Warranty is not transferable and is enforceable by the original
owner only. In the event that Hornady Security® receives notice from the
original purchase of a warranty claim in conformity herewith, Hornady
Security® will promptly undertake an investigation of such claim. If the
warranty claim is covered by the Limited Warranty, Hornady Security® will, in
its sole discretion, repair the defect(s) or replace RAPiD® Safe at the
expense of Hornady Security®.
Disclaimer of Implied Warranties. EXCEPT AS IS OTHERWISE EXPRESSLY SET
FORTH IN THE ABOVE LIMITED WARRANTY, HORNADY SECURITY® MAKES NO OTHER
REPRESENTATIONS OR WARRANTIES OF ANY KIND, WHETHER EXPRESSED OR IMPLIED, BY
OPERATION OF LAW OR OTHERWISE WITH RESPECT TO THE RAPiD® SAFE OR ANY
COMPONENT PART THEREOF, INCLUDING WITHOUT LIMITATION ANY REPRESENTATION OR
WARRANTY WITH RESPECT TO MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR
PURPOSE OR USE.
Limitation on Liability. THE OBLIGATION OF HORNADY SECURITY ® TO REPAIR OR REPLACE AS PROVIDED ABOVE SHALL BE THE SOLE AND ONLY REMEDY RESPECTING ANY DEFECT IN THE RAPiD ® SAFE, OR ANY COMPONENT PART THEREOF. IN THE EVENT THAT THE FOREGOING REMEDY FAILS IN ITS ESSENTIAL PURPOSE, THE LIABILITY OF HORNADY SECURITY ® TO THE PURCHASER SHALL NOT, IN ANY EVENT, EXCEED THE ACTUAL PURCHASE PRICE OF THE NON- CONFORMING GOODS; AND
Limitation on the Nature of Damages. HORNADY SECURITY® SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO THE PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LIQUIDATED, OR PUNITIVE DAMAGES OF ANY NAME, NATURE, OR DESCRIPTION. HORNADY SECURITY® IS NOT RESPONSIBLE FOR DAMAGE TO OR THEFT OF THE RAPiD® SAFE, OR ITS CONTENTS.
Product Registration and Service
You must register your product to obtain a Warranty Service.
Complete the registration form at
hornady.com/warranties.
http://hornady.com/warranties
Scan to register your product to receive the full benefit of its
warranty.
To Receive Warranty Service
To report a warranty claim, call Hornady® at
800-338-3220 to request a return
authorization number. Returns will not be accepted without prior return
authorization by Hornady®.
When a return authorization number has been obtained, be sure all contents
have been removed from the RAPiD® Safe before sending it for service. Hornady®
is not liable for any loss, theft, or damage to personal property.
Post-Warranty Service Information
For issues concerning service after the Limited Warranty
expires, contact Hornady® at
800-338-3220.
Product Serial Number and Key Number Reference
You must register your RAPiD® Safe in order to obtain warranty service. In the event you should need service for your product, please note the following information:
Serial Number ___ (see the back or bottom of safe)
Key Number _____ (see the face of the lock)
After recording the information, store user manual and spare keys in a secure location outside the safe.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
P.O. Box 1848, Grand Island, Nebraska 68802-1848
308-382-1390 •
800-338-3220 • Fax:
308-382-5761 •
hornady.com/contact