Swagelok MS-CRD-FIXTURE Series 5, 10, and 20 Weld Head Tube Fixture Block Instructions
- June 3, 2024
- Swagelok
Table of Contents
Swagelok MS-CRD-FIXTURE Series 5, 10, and 20 Weld Head Tube Fixture Block
Attaching Centering Gauge to Plenum
- Attach a screw (#4-40 UNC), a lock washer, and one end of the lanyard to the side of the plenum with the tapped hole.
- Use a screw (#4-40 UNC) and lock washer to attach the centering gauge to the other end of the lanyard.
Alignment Adjustment Instructions
- Loosen the four cap screws on the fixture side plate pointed to by the arrows on the plenum.
- Place a minimum length of tubing in the collets so it rests across both side plates.
Weld Head Series| Minimum Tubing Length, in. (mm)
---|---
Series 5| 1.50 (38.1)
Series 10| 2.00 (50.8)
Series 20| 3.00 (76.2) - Lock down the stationary fixture side plate and then the loosened fixture side plate using the latches at the top of the fixture side plates.
- Tighten the four cap screws loosened in step 1.
- Release the latching mechanism, and remove the straight length of the tubing.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>