INTRODUCTION

The device is a wireless fingerprint & PIN handle lock, which supports 100 fingerprint users and 155 PIN users. With 4pcs AAA batteries, it can use for about 6 months (based on 30 times/day), and it will remind people to replace batteries intelligently if low battery. Optional Version: With Tuya Bluetooth (supports 100 APP users). People can install the APP to easily access the door with their Smartphone (APP operation can refer to APP manual)
Features:

  • Zinc alloy case
  • 255 users (100 fingerprint+ 155 PIN)
  • PIN length: 4~6 digits
  • With USB port for emergency power
  • With Backup mechanical key for emergency override

Specifications

Hardware User Capacity

Fingerprint PIN

| 255

100 (Includes 1 Master Fingerprint)

155

---|---
PIN Length| 4~6 Digits
Idle Current| S25uA
Working Current| S120mA
Operating Voltage| 4 Units AAA Batteries
Operating Temperature

Physical

| -25 ° C-60 ° C

Zinc-alloy

Dimensions| L165 x W29 x D65.5 (mm)
Shipping Weight| 1.2kg

Carton Inventorykodicam-D100-BT-Wireless-Smart-Door-
Lock-1

INSTALLATION

kodicam-D100-BT-Wireless-Smart-Door-
Lock-2

Simplified Instruction

Function Description| Operation
Enter the Program Mode| * (Master Code) #

(123456 is the factory default master code)

Change the Master Code| 0 (New Code)# (Repeat the New Code)#

(code: 6 digits)

Add Fingerprint User| 1 (Input Fingerprint 3 Times)#

(can add Fingerprints continuously)

Add PIN User| 1 (PIN)#

PIN Length: 4~6 digits

(can add PINs continuously)

Delete user| 2 (Fingerprint)#

2 (PIN)#

2 (User ID)#

(can delete Users continuously)

Exit from the programming mode| *
How to release the door
Fingerprint Access| Input Fingerprint
PIN User| PIN#
Lock Immediately| 0#

PROGRAMMING

Set Master Code

Programming Step

1. Enter Program Mode

| Keystroke Combination

* (Master Code)#

(Factory default is 123456)

---|---
2. Update Master Code| 0 (New Master Code) # (Repeat New Master Code) #

(Master code is any 6 digits)

3. Exit Program Mode| *

Add Users
(Fingerprint user ID: 0~98, PIN user ID: 100~254: PIN length: 4~6 digits)

Programming Step Keystroke Combination

1. Enter Program Mode                                 * (Master Code)# Add Fingerprint User


2. Using Auto ID

(Allows the device to assign FP to next available User ID number)

OR

2. Select Specific ID

(Allows Master to define a specific User ID to associate the FP to)

| 1 (Fingerprint) (Repeat Fingerprint) (Repeat Fingerprint Again)#

The fingerprints can be added continuously.

1 (User ID)# (Fingerprint) (Repeat Fingerprint) (Repeat Fingerprint Again) #

Add PIN User
2. Using Auto ID

(Allows the device to assign PIN to next available User ID number)

OR

2. Select Specific ID

(Allows Master to define a specific User ID to associate the PIN to)

| 1 (PIN)#

The PINs can be added continuously.

1 (User ID) # (PIN) #

3. Exit| *

Delete Users

Programming Step Keystroke Combination
1. Enter Program Mode * (Master Code) #

2. Delete User – By FP or PIN

OR

2. Delete User – By ID number

OR

2. Delete ALL Users

| 2 (Input Fingerprint)/ (Input PIN) # The users can be deleted continuously. 2 (User ID )#

2 (Master Code) #

3. Exit| *

Add/ Delete Master Fingerprint

Programming Step Keystroke Combination
1. Enter Program Mode * (Master Code) #
2. Add Master Fingerprint 5 (Fingerprint) (Repeat Fingerprint)
OR (Repeat Fingerprint Again)
2. Delete Master Fingerprint 5 (Master Code)#
3. Exit *

Master Fingerprint Usage

Using Master Fingerprint to add and delete users

Add Fingerprint or PIN User| 1. Input (Master Fingerprint)

2. Input (Fingerprint Three Times)/ (PIN#)

Repeat Step 2 for additional users

3.   Input (Master Fingerprint) again

Delete Fingerprint or PIN User| 1. Input (Master Fingerprint Twice Within 5s)

2. Input (Fingerprint)/ (PIN#)

Repeat Step 2 for additional users

3.    Input (Master Fingerprint) again

Set Relay Configuration
The relay configuration sets the behavior of the output relay on activation.

Programming Step Keystroke Combination
1. Enter Program Mode * (Master Code)#

2. Pulse Mode

OR

2. Toggle Mode

| 3 (1-99) # (factory default)

The relay time is 1-99 seconds.(Default is 5 seconds)

30#

Sets the relay to ON/OFF Toggle mode

3. Exit| *

Set Access Mode
For Multi fingerprints/PINS access mode, the interval time of reading fingerprints / inputting PINs can not exceed 5 seconds, or else, the device will exit to standby automatically.

2.FingerprintAccess 2 O. R PIN Access O 2. R Fingerprint or PIN Access

O 2. R Multi Fingerprints/ PINs Access

| 40#

42#

43 # (factory default)

43 (2-9)#

(Only after 2~9 users, the door can be opened)

---|---
3. Exit| *

Set Audible and Visual Response

Programming Step Keystroke Combination
1. Enter Program Mode * (Master Code) #

2. Disable Sound Enable Sound

O 2. R Keypad BacklitAlways OFF

Keypad BacklitAutomatic OFFAfter 5s

O 2. R Fingerprint Sensor LED OFF Fingerprint Sensor LED ON

| 60#

6 1 # (factory default)

62#

63 # (factory default)

64#

65 # (factory default)

3. Exit| *

How to Open and Close the Lock

1. Open the Lock| PIN#

Input Fingerprint

---|---
2. Close the Lock| 0#

Reset to factory default
Remove the batteries, press the reset button, hold it and install the batteries, after 5 seconds, the lock beep and the Orange LED bright, then release the reset button, reset to factory default successfully. (The user’s information is still retained)kodicam-D100-BT-Wireless-Smart-Door-
Lock-3

SOUND AND LIGHT INDICATION

Operation Status Red LED Green LED Buzzer
Stand by OFF OFF
Press the key One beep
Enter into programming mode ON One beep
In the programming mode ON ON

Operation error

Open lock

| –

| –

ON

| Threebeeps

One beep

Low battery reminding| Orange LED ON| Threebeeps when press any button