For model: i1040
Smoke Alarm User Guide
Lithium (non-replaceable sealed-in) Battery-Operated Smoke Alarm with Alarm
Memory and SMART HUSH® Control to temporarily silence nuisance alarms.
Thank you for purchasing this smoke alarm. It is an important part of your
family’s home safety plan. You can trust this product to provide the highest
quality safety protection. We know you expect nothing less when the lives of
your family are at stake.
For your convenience, write down the following information. If you call our
Consumer Hotline, these are the first questions you will be asked.
Date Code (located on the back of the alarm): The National Fire Protection
Association (NFPA) and the manufacturer recommend replacing this alarm ten
years from the date code.|
---|---
Date of Purchase:|
Where Purchased:|
This alarm detects products of combustion using the ionization technique. It
contains 0.9 microcuries of Americium 241, a radioactive material (see Section
11). Distributed under U.S. NRC License No. 32-23858-01E. Manufactured in
compliance with U.S. NRC safety criteria in 10 CFR 32.27. The purchaser is
exempt from any regulatory requirements. Do not try to repair the smoke alarm
yourself. Refer to the instructions in Section 15 for service.
IMPORTANT! READ ALL INSTRUCTIONS BEFORE INSTALLATION AND KEEP THIS USER
GUIDE NEAR THE ALARM FOR FUTURE REFERENCE.
CONTENTS OF THIS USER GUIDE
1 — RECOMMENDED LOCATIONS FOR SMOKE ALARMS
2 — LOCATIONS TO AVOID
3 — INSTALLATION INSTRUCTIONS
4 — OPERATION AND TESTING
5 — NUISANCE ALARMS
6 — BATTERY
7 — PERMANENTLY DISABLE ALARM / DISCHARGE BATTERY
8 — MAINTENANCE
9 — LIMITATIONS OF SMOKE ALARMS
10 — GOOD SAFETY HABITS
11 — NRC INFORMATION
12 — NFPA REQUIRED PROTECTION
13 — CALIFORNIA STATE FIRE MARSHAL REQUIRED INFORMATION
14 — FCC
15 — SERVICE AND WARRANTY
RECOMMENDED LOCATIONS FOR ALARMS
-
Locate the first alarm in the immediate area of the bedrooms. Try to monitor the exit path as the bedrooms are usually farthest from the exit. If more than one sleeping area exists, locate additional alarms in each sleeping area.
-
Locate alarms in accordance with local building codes, ordinances, or laws.
-
Locate additional alarms to monitor any stairway as stairways act like chimneys for smoke and heat.
-
Locate at least one alarm on every floor level.
-
Locate an alarm in every bedroom.
-
Locate an alarm in every room where electrical appliances are operated (i.e. portable heaters or humidifiers).
-
Locate an alarm in every room where someone sleeps with the door closed.
-
The closed-door may prevent an alarm not located in that room from waking the sleeper.
-
Smoke, heat, and combustion products rise to the ceiling and spread horizontally. Mounting the smoke alarm on the ceiling in the center of the room places it closest to all points in the room. Ceiling mounting is preferred in ordinary residential construction.
-
For mobile home installation, select locations carefully to avoid thermal barriers that may form at the ceiling. For more details, see MOBILE HOME INSTALLATION below.
-
When mounting an alarm on the ceiling, locate it at a minimum of 4” (10 cm) from the sidewall (see figure 1).
-
When mounting the alarm on the wall, use an inside wall with the top edge of the alarm at a minimum of 4” (10 cm) and a maximum of 12” (30.5 cm) below the ceiling (see figure 1).
-
Put smoke alarms at both ends of a bedroom hallway or large room if the hallway or room is more than 30 feet (9.1 m) long.
-
NFPA 72 states: “Smoke alarms in rooms with ceiling slopes greater than 1 ft in 8 ft (.3m in 2.4 m) horizontally shall be located on the high side of the room.” NFPA 72 states: “A row of detectors shall be spaced and located within 3 ft (0.9m) of the peak of the ceiling measured horizontally.”
MOBILE HOME INSTALLATION
Modern mobile homes have been designed and built to be energy efficient.
Install smoke alarms as recommended above (see figures 1 and 2).
In older mobile homes that are not well insulated compared to present
standards, extreme heat or cold can be transferred from the outside to the
inside through poorly insulated walls and roofs.
This may create a thermal barrier that can prevent the smoke from reaching an
alarm mounted on the ceiling. In such units, install the smoke alarm on an
inside wall with the top edge of the alarm at a minimum of 4” (10 cm) and a
maximum of 12” (30.5 cm) below the ceiling (see figure 1).
If you are not sure about the insulation in your mobile home, or if you notice
that the outer walls and ceiling are either hot or cold, install the alarm on
an inside wall. For minimum protection, install at least one alarm close to
the bedrooms. For additional protection, see SINGLE FLOOR PLAN in figure 2.
WARNING: TEST YOUR SMOKE ALARM OPERATION AFTER MOBILE HOME HAS BEEN IN STORAGE OR UNOCCUPIED AND AT LEAST ONCE A WEEK DURING USE.
LOCATIONS TO AVOID
- In the garage. Products of combustion are present when you start your automobile.
- Less than 4” (10cm) from the peak of an “A” frame type ceiling.
- In an area where the temperature may fall below 40ºF (4.4ºC) or rise above 100ºF (37.8ºC), such as garages and unfinished attics.
- In dusty areas. Dust particles may cause nuisance alarm or failure to alarm.
- In very humid areas (above 95% RH, non-condensing). Moisture or steam can cause nuisance alarms.
- In insect-infested areas.
- Smoke alarms should not be installed within 3 ft (.9m) of the following: the door to a kitchen, the door to a bathroom containing a tub or shower, forced air supply ducts used for heating or cooling, ceiling or whole house ventilating fans, or other high airflow areas.
- Kitchens. Normal cooking may cause nuisance alarms. If a kitchen alarm is desired, it should have an alarm silence feature or be a photoelectric type.
- Near fluorescent lights. Electronic “noise” may cause nuisance alarms.
- Smoke alarms are not to be used with detector guards unless the combination (alarm and guard) has been evaluated and found suitable for that purpose.
INSTALLATION INSTRUCTIONS
CAUTION: THIS UNIT IS SEALED (INCLUDING THE BATTERY). THE COVER IS NOT REMOVABLE! REMOVING THE COVER WILL IMPACT DEVICE FUNCTIONALITY AND VOID WARRANTY.
-
To insure aesthetic alignment of the alarm with the hallway or wall, the “A” line on the mounting bracket should be parallel with the hallway when ceiling mounting or horizontal when wall mounting.
-
After selecting the proper smoke alarm location as described in Section 1, attach the mounting bracket to the ceiling as shown in figure 3. For wall mounting see figure 4. Place the mounting plate on the wall; be sure the “A” line is horizontal (parallel to the floor). Use the screws and anchors provided to secure the mounting bracket (use a 3/16” drill bit for anchors).
-
This alarm has a battery permanently sealed inside the alarm no battery installation is necessary.
ACTIVATING THE ALARM
This model is equipped with a feature that automatically activates the alarm
when the alarm is mounted to the mounting bracket for the first time.
This battery activation is a one-time action, and cannot be reversed. Once
activated the battery will supply power to the alarm for the life of the alarm
(10 years). Be sure that the mounting bracket is mounted correctly before
installing the alarm on the mounting bracket.
-
To activate the alarm, install the alarm on the mounting bracket (figure 6) and rotate the alarm clockwise (as indicated on the alarm cover) until the alarm ratchets into place.
NOTE: The alarm will mount to the bracket in three (3) positions.
The alarm is now activated! -
After installation/activation, test your alarm by pushing and releasing the button. This should sound the alarm.
CAUTION: Due to the loudness (85 decibels) of the alarm, always stand at least 2.5 feet away from the unit when testing. Exposure at a close distance may be harmful to your hearing.
OPERATION AND TESTING
OPERATION : The smoke alarm is operating once the alarm is activated (see Section 3) and testing is complete. When products of combustion are sensed, the unit sounds a loud 85db pulsating alarm until the air is cleared.
SMART HUSH® CONTROL: The SMART HUSH® feature has the capability of temporarily
desensitizing the alarm circuit for approximately 8 minutes. This feature is
to be used only when a known alarm condition, such as smoke from cooking,
activates the alarm. The smoke alarm is desensitized by pushing the button on
the smoke alarm cover. If the smoke is not too dense, the alarm will silence
immediately and the red LED will flash every 8 seconds for up to 8 minutes.
This indicates that the alarm is in a temporarily desensitized condition. The
smoke alarm will automatically reset after approximately 8 minutes and sound
the alarm if particles of combustion are still present.
The SMART HUSH SMART HUSH® used repeatedly until the air has been cleared of
the condition causing the alarm. Pushing the button on the alarm will end the
temporarily desensitized period.
NOTE: DENSE SMOKE WILL OVERRIDE THE SMART HUSH® CONTROL FEATURE AND SOUND
A CONTINUOUS ALARM.
CAUTION: BEFORE USING THE ALARM SMART HUSH® FEATURE, IDENTIFY THE SOURCE
OF THE SMOKE AND BE CERTAIN A SAFE CONDITION EXISTS.
FLASHING LED LIGHT : This smoke alarm is equipped with a flashing red
indicator light with four modes of operation:
- The LED will flash every 40-45 seconds in the standby mode signifying that the alarm is receiving power.
- The LED will flash every 1.5 seconds when the alarm is sounding.
- The LED will flash every 8 seconds while the alarm is in the temporarily desensitized mode.
- If alarm memory has been set (see below for alarm memory description), the LED will flash rapidly when the button is pressed.
ALARM MEMORY : This smoke alarm has a memory function that will inform
you if the alarm has sounded since the button was last pressed. The alarm
memory will cause the red LED to flash rapidly when the button is pressed. The
alarm memory is reset when the button is released.
TESTING : Test by pushing and releasing the button. This will sound the
alarm if the electronic circuitry, horn, and battery are working. If no alarm
sounds, the unit has a defective battery or another failure.
** DO NOT use an open flame to test your alarm, you could damage the alarm
or ignite combustible materials and start a structure fire.
NOTE: WEEKLY TESTING IS REQUIRED.**
TEST THE ALARM WEEKLY TO ENSURE PROPER OPERATION. Erratic or low sound coming
from your alarm may indicate a defective alarm, and it should be returned for
service (see Section 15).
NUISANCE ALARMS
Smoke alarms are designed to minimize nuisance alarms. Cigarette smoke will
not normally set off the alarm unless the smoke is blown directly into the
alarm. Combustion particles from cooking may set off the alarm if the alarm is
located close to the cooking area. Large quantities of combustible particles
are generated from spills or when broiling. Using the fan on a range hood that
vents to the outside (non-recirculating type) will also help remove these
combustible products from the kitchen.
This model has a SMART HUSH® control that is extremely useful in a kitchen
area or other areas prone to nuisance alarms. For more information refer to
Section 4, OPERATION AND TESTING.
If the alarm does sound, check for fires first. If a fire is discovered, get
out and call the fire department. If no fire is present, check to see if one
of the reasons listed in Section 2 may have caused the alarm.
Battery
NOTE: One Lithium battery, permanently sealed inside the alarm, powers
this unit; no battery installation or replacement is necessary for the life of
the alarm.
WARNING! DO NOT ATTEMPT TO OPEN THE ALARM FOR ANY REASON!
CAUTION: THE BATTERY USED IN THIS DEVICE MAY PRESENT A FIRE OR CHEMICAL
BURN HAZARD IF MISTREATED. DO NOT RECHARGE, DISASSEMBLE, HEAT ABOVE 100°C
(212°F) OR DISPOSE OF IN FIRE.
To activate the alarm, attach the alarm to the mounting bracket by rotating in
the direction of the arrows on the cover, see ACTIVATING ALARM in Section 3
(INSTALLATION INSTRUCTIONS).
Low battery : This alarm has a battery monitor circuit which will cause
the alarm to “chirp”, (every 40 to 45 seconds), when the battery is low. The
alarm will “chirp” for a minimum of thirty (30) days. REPLACE THE ALARM
IMMEDIATELY.
THE UNIT MUST BE DISCHARGED (see “Permanently Disable Alarm / Discharge
Battery” section) when the alarm is in “low battery” condition.
PERMANENTLY DISABLE ALARM / DISCHARGE BATTERY
WARNING!
- Discharging the battery is permanent. Once the alarm has been discharged, it cannot be reactivated!
- Once discharged, the alarm will NO LONGER DETECT SMOKE.
- Once the alarm is discharged the battery will be depleted and the alarm will no longer function.
- Once the alarm has been discharged, it cannot be mounted onto the mounting plate or reactivated.
To Permanently Disable Alarm / Discharge Battery:
-
Push in the dashed area with a screwdriver to completely break tab.
-
After the tab is broken, use the screwdriver to break through the label and turn the slotted arrow counter-clockwise to the “PERMANENTLY DISABLE and DISCHARGE alarm” location. This will disable the alarm, stop the low battery “chirps” and render the alarm safe for disposal by draining the battery.
WARNING! Failure to DISCHARGE alarm as instructed prior to disposal may
create the potential for lithium battery-related fire or hazard.
CAUTION: Do not disassemble and do not dispose of in fire.
MAINTENANCE
CLEANING YOUR ALARM
YOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEAR
To clean your alarm, remove it from the mounting bracket (Rotating it
counterclockwise). You can clean the interior of your alarm (sensing chamber)
by using compressed air
and blowing through the openings around the perimeter of the alarm. The
outside of the alarm can be wiped with a damp cloth only. Do not spray with
liquid or foam cleanser, as doing so may damage the device. After cleaning,
reinstall your alarm and test your alarm by using the button. If cleaning does
not restore the alarm to normal operation the alarm should be replaced.
LIMITATIONS OF SMOKE ALARMS
WARNING: PLEASE READ CAREFULLY AND THOROUGHLY
-
NFPA 72 states: Life safety from fire in residential occupancies is based primarily on early notification to occupants of the need to escape, followed by the appropriate egress actions by those occupants. Fire warning systems for dwelling units are capable of protecting about half of the occupants in potentially fatal fires. Victims are often intimate with the fire, too old or young, or physically or mentally impaired such that they cannot escape even when warned early enough that escape should be possible.
For these people, other strategies such as protection-in-place or assisted escape or rescue are necessary. -
Leading authorities recommend that both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fires that can occur within the home. Ionization sensing alarms may detect invisible fire particles (associated with fast flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible fire particles (associated with slow smoldering fires) sooner than ionization alarms.
-
A battery-powered alarm must have a battery of the specified type, in good condition, and installed properly. (This model has a sealed battery)
-
Smoke alarms must be tested regularly to make sure the battery and the alarm circuits are in good operating condition.
-
Smoke alarms cannot provide an alarm if smoke does not reach the alarm. Therefore, smoke alarms may not sense fires starting in chimneys, walls, on roofs, on the other side of a closed-door or on a different floor.
-
If the alarm is located outside the bedroom or on a different floor, it may not wake up a sound sleeper.
-
The use of alcohol or drugs may also impair one’s ability to hear the smoke alarm. For maximum protection, a smoke alarm should be installed in each sleeping area on every level of a home.
-
Although smoke alarms can help save lives by providing an early warning of a fire, they are not a substitute for an insurance policy. Homeowners and renters should have adequate insurance to protect their lives and property.
GOOD SAFETY HABITS
DEVELOP AND PRACTICE A PLAN OF ESCAPE
- Install and maintain Fire extinguishers on every level of the home and in the kitchen, basement, and garage. Know how to use a fire extinguisher prior to an emergency.
- Make a floor plan indicating all doors and windows and at least two (2) escape routes from each room. Second-story windows may need a rope or chain ladder.
- Have a family meeting and discuss your escape plan, showing everyone what to do in case of fire.
- Determine a place outside your home where you all can meet if a fire occurs.
- Familiarize everyone with the sound of the smoke alarm and train them to leave your home when they hear it.
- Practice a fire drill at least every six months, including fire drills at night. Ensure that small children hear the alarm and wake when it sounds. They must wake up in order to execute the escape plan. Practice allows all occupants to test your plan before an emergency. You may not be able to reach your children. It is important they know what to do.
- Current studies have shown smoke alarms may not awaken all sleeping individuals, and that it is the responsibility of individuals in the household that are capable of assisting others to provide assistance to those who may not be awakened by the alarm sound, or to those who may be incapable of safely evacuating the area unassisted.
WHAT TO DO WHEN THE ALARM SOUNDS
- Alert small children in the home.
- Leave immediately by your escape plan. Every second counts, so don’t waste time getting dressed or picking up valuables.
- In leaving, don’t open any inside door without first feeling its surface. If hot, or if you see smoke seeping through cracks, don’t open that door! Instead, use your alternate exit. If the inside of the door is cool, place your shoulder against it, open it slightly and be ready to slam it shut if heat and smoke rush in.
- Stay close to the floor if the air is smoky. Breathe shallowly through a cloth, wet if possible.
- Once outside, go to your selected meeting place and make sure everyone is there.
- Call the fire department from your cell phone outside, or your neighbor’s home – not from yours!
- Don’t return to your home until the fire officials say that it is all right to do so.
There are situations where a smoke alarm may not be effective to protect against fire as stated in the NFPA Standard 72. For instance:
a) smoking in bed
b) leaving children home alone
c) cleaning with flammable liquids, such as gasoline
NRC INFORMATION
Ionization type smoke alarms use a very small amount of a radioactive element
in the sensing chamber to enable the detection of visible and invisible
combustion products.
The radioactive element is safely contained in the chamber and requires no
adjustments or maintenance. This smoke alarm meets or exceeds all government
standards. It is manufactured and distributed under license from the U.S.
Nuclear Regulatory Commission.
NFPA REQUIRED PROTECTION
Fire Safety in the Home: NFPA 72 is intended to provide reasonable safety for
persons in family living units. Reasonable fire safety can be produced through
the following three-point program:
(1) Minimizing fire hazards
(2) Providing fire-warning equipment
(3) Having and practicing an escape plan.
The National Fire Protection Association’s Standard 72 provides the following
information:
Where required by other governing laws, codes, or standards for the specific
type of occupancy approved single and multiple-station smoke alarms shall be
installed as follows:
(1) In all sleeping rooms and guest rooms.
(2) Outside of each separate dwelling unit sleeping area, within 21 ft (6.4 m)
of any door to a sleeping room, with the distance measured along a path of
travel.
(3) On every level of a dwelling unit, including basements.
(4) On every level of a residential board and care occupancy (small facility),
including basements and excluding crawl spaces and unfinished attics.
(5) In the living area(s) of a guest suite.
(6) In the living area(s) of a residential board and care occupancy (small
facility).
Smoke Detection – Are More Smoke Alarms Desirable?
The required number of smoke alarms might not provide reliable early warning
protection for those areas separated by a door from the areas protected by the
required smoke alarms. For this reason, it is recommended that the householder
consider the use of additional smoke alarms for those areas for increased
protection. The additional areas include the basement, bedrooms, dining room,
furnace room, utility room, and hallways not protected by the required smoke
alarms. The installation of the smoke alarms
in the kitchen, attic (finished or unfinished), or garage is normally not
recommended, as these locations occasionally experience conditions that can
result in improper operation.
This equipment should be installed in accordance with the National Fire
Protection Association’s Standard 72 (NFPA, Batterymarch Park, Quincy, MA
02269). NOTIFY YOUR LOCAL FIRE DEPARTMENT AND INSURANCE COMPANY OF YOUR SMOKE
ALARM INSTALLATION.
**** CAUTION (AS REQUIRED BY THE CALIFORNIA STATE FIRE MARSHAL)
“Early warning fire detection is best achieved by the installation of fire
detection equipment in all rooms and areas of the household as follows. A
smoke alarm is installed in each separate sleeping area (in the vicinity of,
but outside of the bedrooms), and heat or smoke detectors in the living rooms,
dining rooms, bedrooms, kitchens, hallways, attics, furnace rooms, closets,
utility and storage rooms, basements and attached garages”.
The NFPA suggests that alarms installed within 20′ (6.1m) of cooking
appliances shall have an alarm silence feature or be of the photoelectric
type.
FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
SERVICE AND WARRANTY
If after reviewing this user guide you feel that your smoke alarm is defective in any way, do not tamper with the unit. Disable the alarm and discharge the battery (see Section 7) and then return it for servicing to KIDDE, 1016 Corporate Park Dr., Mebane, NC 27302. 1-800-880-6788 (See Warranty for in- warranty returns).
TEN YEAR LIMITED WARRANTY
Walter Kidde Portable Equipment, Inc. (“KIDDE”) warrants to the original
purchaser that the enclosed smoke alarm will be free from defects in material
and workmanship or design under normal use and service for a period of ten
years from the date of purchase. The obligation of KIDDE under this warranty
is limited to repairing or replacing the smoke alarm or any part which we find
to be defective in material, workmanship, or design, free of charge to the
customer, upon sending the smoke alarm with proof of date of purchase, postage
and return postage prepaid, to Warranty Service Department, KIDDE, 1016
Corporate Park Dr., Mebane, NC 27302.
This warranty shall not apply to the smoke alarm if it has been damaged,
modified, abused, or altered after the date of purchase or if it fails to
operate due to improper maintenance or inadequate AC or DC electrical power.
THE LIABILITY OF KIDDE OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS ARISING
FROM THE SALE OF THIS SMOKE ALARM OR UNDER THE TERMS OF THIS LIMITED WARRANTY
SHALL NOT, IN ANY CASE, EXCEED THE COST OF REPLACEMENT OF THE SMOKE ALARM AND,
IN NO CASE, SHALL KIDDE SAFETY OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS
BE LIABLE FOR CONSEQUENTIAL LOSS OR DAMAGES RESULTING FROM THE FAILURE OF THE
SMOKE ALARM OR FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED,
EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE COMPANY’S NEGLIGENCE OR FAULT.
Since some states do not allow limitations on the duration of an implied
warranty or do not allow the exclusion or limitation of incidental or
consequential damages, the above limitations or exclusions may not apply to
you. While this warranty gives you specific legal rights, you may also have
other rights which vary from state to state. The above warranty may not be
altered except in writing signed by both parties hereto.
QUESTIONS OR FOR MORE INFORMATION
Call our Consumer Hotline at
1-800-880-6788 or contact
us at our website at www.kidde.com
Kidde, 1016 Corporate Park Drive, Mebane, NC 27302
Made in China
P/N 0920-7201-02 EN 06/17