VULCAN VCRG24-M Medium Duty Gas Griddles Instruction Manual
- June 5, 2024
- Vulcan
Table of Contents
- VULCAN VCRG24-M Medium Duty Gas Griddles
- IMPORTANT FOR YOUR SAFETY
- IMPORTANT
- INSTALLATION, OPERATION AND CARE OF MEDIUM DUTY GAS GRIDDLES
- STALLATION CODES AND STANDARDS
- GRIDDLES MOUNTED ON STANDS WITH CASTERS
- OPERATION
- VCRG-M / WCRG-M PILOT LIGHTING PROCEDURE
- CLEANING THE GRIDDLE
- MAINTENANCE
- TROUBLESHOOTING
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
VULCAN VCRG24-M Medium Duty Gas Griddles
IMPORTANT FOR YOUR SAFETY
THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER.
IMPORTANT
IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
Warning:
Improper installation, adjustment, alteration, service or maintenance can
cause property damage, injury, or death. Read the installation, operating and
maintenance instructions thoroughly before installing or servicing this
equipment.
INSTALLATION, OPERATION AND CARE OF MEDIUM DUTY GAS GRIDDLES
GENERAL
Medium Duty Gas Griddles are produced with quality workmanship and materials.
Proper installation, usage and maintenance of your griddle will result in many
years of satisfactory performance. Thoroughly read this entire manual and
carefully follow all of the instructions provided .
Model | Number Of Burners | BTU/hr Input Rating |
---|---|---|
VCRG24-M / WCRG24-M | 2 | 50,000 |
VCRG36-M / WCRG36-M | 3 | 75,000 |
VCRG48-M / WCRG48-M | 4 | 100,000 |
UNPACKING
This griddle was inspected before leaving the factory. The carrier assumes
full responsibility for the safe delivery upon acceptance of the shipment.
Check for possible shipping damage immediately after receipt.
If the griddle is found to be damaged, complete the following steps:
- The carrier must be notified within 5 business days of receipt.
- Carrier’s local terminal must be notified immediately upon discovery (note time, date, and who was spoken to), and follow up and confirm with written or electronic communication.
- All original packing materials must be kept for inspection purposes.
- The griddle cannot have been moved, installed, or modified.
- Notify Vulcan Customer Service immediately at 800-814-2028.
Carefully unpack your griddle and make sure that no parts are discarded with packaging material. A pressure regulator designed to operate with the griddle has been supplied and must be installed before the griddle is placed into service (Refer to GAS PRESSURE REGULATOR INSTALLATION in this manual).
LOCATION
The installation location must be kept free and clear of combustibles. When
installing, never enclose the bottom of the griddle with a raised curb or
other constructions that would obstruct flow of air into or out of the
griddle. Adequate clearance for air openings into the combustion chamber must
be provided. Make sure there is an adequate supply of air in the room to
replace air taken out by the ventilation system. Do not permit air to blow
directly at the griddle. Avoid open windows next to the griddle wherever
possible. Avoid wall-type fans which create air cross-currents within the
room.This griddle is Design Certified for installation on a non-combustible
counter with 4” legs, or combustible floor with 24” high stand.
INSTALLATION CLEARANCES
COMBUSTIBLE CONSTRUCTION | NON-COMBUSTIBLE CONSTRUCTION |
---|---|
Back: | 6” |
Sides: | 6” |
STALLATION CODES AND STANDARDS
The griddle must be installed in accordance with: In the United States of America:
-
State and local codes.
-
National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained from The American Gas Association Accredited Standards Committee Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-7471
NOTE:
In the Commonwealth of Massachusetts All gas appliances vented through a ventilation hood or exhaust system equipped with a damper or with a power means of exhaust shall comply with 248 CMR. -
NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. In Canada:
-
Local codes.
-
CAN/CSA-B149.1 Natural Gas Installation (latest edition)
-
CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3
GRIDDLES MOUNTED ON STANDS WITH CASTERS
Griddles mounted on stands with casters must use a flexible connector (not supplied) that complies with the Standard for Connectors for Movable Gas Appliances ANSI Z21.69•CSA6.16, and a quick-disconnect device that complies with Gas Fuel, ANSI Z21.3•CSA6.9. In addition, adequate means must be provided to limit movement of the appliance without depending on the connector and the quick-disconnect device (or its associated piping) to limit appliance movement. Attach the restraining device at the rear of the griddle as shown in Fig. 1.
If disconnection of the restraint is necessary, turn off the gas supply before disconnecting. Reconnect the restraint prior to turning the gas supply on and returning the griddle to its installation position. Casters are only supplied on a griddle stand. If the griddle is moved for any reason the griddle should be re-leveled (see LEVELING in this manual).
FLUE CONNECTIONS
Do not obstruct the flow of flue gases from the flue, located at the rear of
the griddle. It is recommended that flue gases be ventilated to the outside of
the building through a ventilation system installed by qualified
personnel.From the termination of the flue to the filters of the hood venting
system, a minimum clearance of 18” must be maintained.Information on the
construction and installation of ventilating hoods may be obtained from the
standard for “Vapor Removal from Cooking Equipment”, NFPA No. 96 (latest
edition), available from the National Fire Protection Association,
Batterymarch Park, Quincy, MA 02269.
GAS CONNECTIONS
Gas supply connections and any pipe joint compound must be resistant to the
action of propane gases. Use a ¾” NPT gas supply line for the griddle inlet,
located at the rear of the griddle. All of flexible and semi-rigid gas supply
lines must comply with the applicable ANSI standard. To ensure maximum
operating efficiency, this appliance must be connected with a gas supply line
of solid pipe or a commercial type Flexible Connector with the net inside
diameter (I.D.) as large as or larger than the gas pipe inlet on this
appliance. Codes require that a gas shutoff valve must be installed in the gas
line upstream of the griddle. Prior to lighting, check all joints in the gas
supply line for leaks. Use soap and water solution. Do not use an open flame.
After checking for leaks all lines receiving gas should be fully purged to
remove air.
TESTING THE GAS SUPPLY SYSTEM
When the gas supply pressure exceeds ½ psig (3.45 kPa), the griddle and its
individual shutoff valve must be disconnected from the gas supply piping
system. When the gas supply pressure is ½ psig (3.45 kPa) or less, the griddle
should be isola ted from the gas supply system by closing its individual
manual shutoff valve.
GAS PRESSURE REGULATOR INSTALLATION
This griddle is supplied with a convertible gas pressure regulator preset at
4” Water Column (W.C.) for natural gas. No further adjustment should be
required. Install the regulator as close to the griddle on the gas supply line
as possible. Make sure that the arrow on the underside of the regulator is
oriented in the direction of gas flow to the griddle (Fig. 2 on next page) and
the regulator is positioned with the vent plug and conversion plug cover
upright (Fig. 3 on next page).
The supply pressure (upstream of the regulator) should be 7-9” W.C. for natural gas and 11-12” W.C. for propane gas. At no time should the griddle be connected to supply pressure greater than ½ psig (3.45 kPa) or 14” W.C.
PROPANE GAS CONVERSION
This griddle is shipped from the factory equipped with fixed burner and pilot
orifices for natural gas operation. The burner and pilot orifices required to
convert the griddle to propane gas are shipped with the griddle in the
shipping packaging. It is recommended that a trained gas service technician
with the necessary tools, instruments and skills perform the conversion To
convert to propane, following steps must be completed:
- . Remove all natural gas burner orifices and install the provided p ropane burner orifices. See Fig. 4
- . Remove all pilot orifices and install the provided propane pilot orifices. S ee Fig 4.
- Set the regulator to 10” W.C. by inverting the regulator spring plug. See Fig 5.
Prior to lighting, check all joints in the gas supply line for leaks. Use soap and water solution. Do not use an open flame.
OPERATION
The griddle and its parts are hot. Use care when operating, cleaning or servicing the griddle.
BEFORE FIRST USE
Remove all packing material and protective plastic from surfaces of the unit.
Before leaving the factory the griddle is coated with vegetable oil as a rust
inhibitor. Remove this film when the griddle plate is being cleaned prior to
its first cooking use. Heat the griddle to 200-300°F to loosen and melt the
coating, then clean the surface with a non-corrosive, grease dissolving
commercial cleaner, following the manufacturer’s directions. Rinse thoroughly
and wipe dry with a soft clean cloth. Clean all accessories.
SEASONING THE GRIDDLE
Season the griddle to avoid possible surface corrosion before first use, and
after every cleaning. Heat griddle to a low temperature (300-350°F) and apply
a small amount of cooking oil – about one ounce per square foot of surface.
Use a soft lint-free cloth to spread the oil over the entire griddle surface
to create a thin film. Wipe off any excess oil with a cloth. Repeat the
procedure until the griddle has a slick, mirror-like finish. This will also
help reduce the sticking of cooked food product.
CONTROLS
There is one pilot for every two burners except on the 36” models. The 36”
models have an odd number of main burners; therefore one of the pilots in
these models will control only one main burner. The pilot burners are off
centered about 1” to the left of pilot sight holes and inset approximately 7”
from the front panel. See cutaway view on page 8.The unit is equipped with
standing, unmonitored pilots. Gas will flow from the pilots as soon as the
main gas supply to the unit is turned on. The pilots are lit with the use of
an outside ignition source (such as a lit taper, etc). See pilot lighting
procedure on page 8.Each 12” section of the griddle is independently
controlled by an infinite heat control valve. Once the pilots are lit, turning
the control knob to the ON position will light each burner. The burners will
be in the full ON position when turned all the way to the left. The burners
will be in the full OFF position when turned all the way to the right. See
Fig. 6. The height of the burner flame and plate temperature can be adjusted
by turning control knobs while viewing burners through the burner sight
holes.
VCRG-M / WCRG-M PILOT LIGHTING PROCEDURE
- Turn the main gas shut-off valve and all burner control knobs to the OFF position. Wait 5 minutes to allow any gas that may have accumulated in the burner compartment to escape.
- Turn the main gas shut-off valve ON.
- While viewing through the pilot sight hole, you will have to reach under the front of the unit and through the pilot cutout to ignite the pilots with an outside ignition source(such as a lit taper, etc.). It may be necessary to adjust the pilot valve to increase gas to the pilot. See Fig. 7 on page 11.
- Repeat steps until all pilots are lit
- To light main burners, turn individual burner valves to the ON position.
- If after completing steps 1-5 main burners do not light, turn off the main gas shut-off valve and contact an authorized service contractor.
USING THE GRIDDLE
To preheat, turn the burners on about 20-25 minutes before cooking.A uniform
and systematic approach to loading the griddle will produce the most
consistent product results.The griddle plate is steel, but the surface is
relatively soft and can be scored or dented by careless use of a spatula or
scraper. Be careful not to dent, scratch, or gouge the plate surface. Do not
try to knock off loose food that may be on the spatula by tapping the corner
or the edge of the spatula on the griddle surface.
ZONE COOKING
This griddle features a tubular U-shaped burner in each 12” section, each
controlled by independent valves. Each 12” section is a separate cooking zone,
and allows cooking a wide variety of products over a single griddle plate. The
chart below is a suggested usage of zone cooking.When zone cooking, it is
suggested that you start with your lowest temperature setting at either side
of the griddle, increasing the zone temperature as you move up the zone line.
These zone cooking guidelines will vary depending on product temperatures,
size and shape. This guide should be adjusted to suit your product and
operational cooking preference.
ZONE 1 (300°F)| ZONE 2 (350°F)| ZONE 3 (350°F)| ZONE 4
(400°F)
---|---|---|---
PRODUCT
Sausage
Eggs ( Hard Fried) Eggs ( Scram bled) Burger ( Well Done) Steak ( Well Done) Chicken Breast
Frozen Foods Pork Chops
| PRODUCT| PRODUCT
Steak ( Rare)
Stir Fry Vegetables Salm on
Fish Cakes Lobster
Scam pi
Pancakes
French Toast Bacon
| Omelet
Hash Browns
Canadian Bacon
Eggs ( Sunny Side Up) Boiled Ham
Steak ( Medium Well)
Fresh Burger ( Medium Well)
Small Frozen Burger ( Medium Well)
It is recommended to avoid using ice to rapidly cool the griddle surface
temperature. Doing so could result in thermal shock and damage to the cooking
surface.
CLEANING THE GRIDDLE
Empty the grease drawer as needed throughout the day and regularly clean at least once daily.Clean the griddle regularly. A clean griddle always looks better, lasts longer and performs better. To produce evenly cooked, perfectly browned griddle products keep the griddle plate clean and free of carbonized grease. Carbonized grease on the surface hinders the transfer of heat from the griddle surface to the food, resulting in spotty browning and loss of cooking efficiency. Carbonized grease tends to cling to griddle foods, giving them a highly unsatisfactory and unappetizing appearance. To keep the griddle clean and operating at peak efficiency, follow these procedures:
AFTER EACH USE
Clean the griddle with a wire brush of flexible spatula.
ONCE PER DAY
Thoroughly clean the griddle back splash, sides and front. Remove, empty and
wash the grease drawer in the same manner as an ordinary cooking utensil.
ONCE PER WEEK
Clean the griddle surface thoroughly. Use a griddle stone, screen, or Scotch
Bright pad on the surface as necessary. Rub with the grain of the metal while
the griddle is still warm (not hot). A detergent may be used on the plate
surface to help clean it, but be sure the detergent is thoroughly removed by
flushing with clear water.After removal of detergent the surface of the plate
the griddle should be se asoned according to the instructions in this
manual.Clean stainless steel surfaces with a damp cloth and polish with a soft
dry cloth. To remove discoloration, use a griddle cleaner.If the griddle usage
is very high, consider conducting this weekly cleaning procedure more than
once per week.
LEVELING
The griddle must be level (side-to-side and front-to-back) during operation to
ensure proper performance. Improper leveling can result in uneven temperature
distribution, cold spots, and possibly damaged components.
- Place a level on the griddle.
- Adjust legs by turning the bullet feet at the bottom of each leg. Using pliers or a crescent wrench, turn the feet counter-clockwise to increase height, and clockwise to decrease height until leveling is achieved. Do not extend the legs more than 1-¾”.
PILOT ADJUSTMENT
Using a flathead screwdriver, turn the slotted hex-head pilot adjustment screw
clockwise to decrease the flame, and counterclockwise to increase the flame.
See Fig. 7.
SHUTDOWN OF GRIDDLE WITH STANDING PILOT SYSTEM
- Turn burner control knobs to the OFF position to cut off burners.
- The pilots will remain lit as long as the main gas supply is on.
EXTENDED SHUTDOWN
- Shut off the main gas supply valve.
- Apply a heavy coat of vegetable oil over the griddle plate to inhibit rust.
MAINTENANCE
The griddle and its parts are hot. Use care when operating, cleaning or servicing the griddle.
LUBRICATION
All valves must be checked and lubricated periodically. Check with your
service agency for details.
VENT
Daily, when the griddle is cool, check the flue and clear any obstructions.
SERVICE AND PARTS INFORMATION
Contact the Service Contractor in your area to obtain service and parts
information. For a complete listing of Service and Parts depots refer to or
www.vulcanequipment.com. When calling for service, the following information
should be available from the appliance identification plate: Model Number,
Serial Number and Gas Type.
TROUBLESHOOTING
PROBLEM | POSSIBLE CAUSES |
---|
Burner does not come on when the control knob is turned on
| ****
1. Problem with gas valve. (Call for service)
2. Pilot burner not lit. (Call for service)
3. Low gas pressure. (Call for service)
Pilot burner will not light
| ****
1. Manual gas valve not turned on.
2. Obstructed pilot orifice. (Call for service)
3. Pilot gas turned off at pilot. Adjust pilot to allow gas flow.
4. Low gas pressure. (Call for service)
Pilot burner will not stay lit
| ****
1. Obstructed or wrong size pilot orifice. (Call for service)
2. Gas supply not purged of air. Open pilot valve until air is purged.
3. Air blowing pilot out. (Call for service)
4. Low gas pressure. (Call for service)
Fat appears to smoke excessively
| ****
1. Temperature set too high.
2. Moisture in food may be turning into steam
Food sticks to griddle or burned around edges or contains dark specs
| ****
1. Temperature set too high.
2. Griddle surface requires cleaning and/or seasoning.
3. Surface under food not covered with enough cooking oil.
Food under-cooked inside
| ****
1. Temperature set too low.
2. Food not cooked for long enough time.
Food tastes greasy or has objectionable off-flavor
| ****
1. Food itself may have off-flavor.
2. Food stored improperly before cooking.
3. Too much griddle fat used.
4. Temperature set too low.
Noticeable build-up of gum on griddle
| ****
1. Temperature set too high.
2. Griddle surface needs cleaning and/or seasoning.
3. Too much griddle fat used.