CEG PC-1100 ELECTRONIC PRESSCONTROL User Manual
- June 5, 2024
- CEG
Table of Contents
ELECTRONIC PRESSCONTROL PC-1100
PRODUCT DESCRIPTION
PRESS CONTROL is a device that guarantees optimal control of pumps for domestic use. Deriving from a hydraulic and electronic logic project for the Australian and New Zealand market, it is capable of simultaneously detecting both the pressure and the flow, as well as automatically managing the pump operation. It replaces the traditional pressure controller and pressure tank, protecting the pump in the case of water shortages. PRESS CONTROL:
- Starts and stops the pump in accordance with the opening and closing of the taps
- Maintains constant pressure during delivery
- Stops the pump in the case of water shortage, protecting it from dry running
- Maintenance-free
TECHNICAL DATA
Water temperature range min/max | 5°C – 40°C |
---|---|
Ambient temperature | 0°C – 50°C |
Max. working pressure | 10 bar |
Start pressure | 1.5 bar |
Inlet/outlet pipe connection | 25 mm BSP / 1” Inch BSP |
Max particle size | 1 mm (non-abrasive material) |
Electrical supply | 220V – 240V, 50 Hz |
Electrical connection | AS/NZ plug fitted to 1.5m lead |
Max current | 10 A |
Software version | 2400 W |
Table 5.0
UNIT STARTING AND WORKING
STARTING
When the unit is connected to the electrical network, the green LED “Power On” lights up and the yellow LED “Pump On” indicates that the pump is in operation. The pump continues to operate for up to 5 seconds enabling the system to fill the pipes and reach the required pressure. If this is insufficient, the red LED “Failure” lights up. In this event, eep the “Restart” button pressed and wait with a tap open until the red LED “Failure” light is off. Once the button is released and the tap is closed, the unit stops the pump is at its maximum pressure.
FUNCTIONING
When starting operation is achieved, the unit is programmed to perform all the pump control operations automatically. When particular operational breakdowns occur, such as a failure, obstruction of the suction pipe, etc, the unit recognizes the breakdown and the red LED “Failure” lights up. At the same time, a stop signal is sent to the pump to prevent damages caused by its working in the absence of water. Rectification of the failures that have caused the blockage, allows the system to be restarted manually by pressing the “Restart” button.
INSTRUCTIONS FOR CORRECT UNIT INSTALLATION
Every care has been taken to ensure the accuracy of the information
contained in this publication, but due to continuous development and
improvement, the right is reserved to supply products that may differ slightly
from those illustrated and described in this publication.
www.ceg.co
Documents / Resources
| CEG
PC-1100 ELECTRONIC
PRESSCONTROL
[pdf] User Manual
PC-1100 ELECTRONIC PRESSCONTROL, PC-1100, ELECTRONIC PRESSCONTROL
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>