QwikProducts QT2730 TripleGuard Whole House UV Air Purification System
How it Works…
Industrial-Grade Air Purifier/Sanitizer by Mainstream Engineering Corporation
With proper care, this advanced purification system provides you with years of
fresh, clean, odor-free air.
For safety reasons and to maximize performance of this unit, please read the
manual completely and ensure you understand all safety and assembly
instructions before proceeding. If any section of this manual is unclear,
please resolve the issue by contacting Mainstream Engineering Corporation at
1-800-866-3550 or
1-321-631-3550 before proceeding.
All instructions and precautions MUST be adhered to while installing and
operating this system.
CAUTION: NEVER LOOK DIRECTLY AT AN ILLUMINATED CELL. THIS DEVICE PRODUCES
GERMICIDAL UV-C LIGHT AND WILL CAUSE DAMAGE TO EYES.
Inserted Dimensions
Height| 7″| Depth| 9.1″
Width| 10.4″| Weight| 7.5 lbs
Power
120, 208 or 240 VAC single-phase| 0.8A @ 120V or 0.4A @ 240V
Introduction
The industrial-grade patent-pending QwikPure TripleGuard™ Air Purifier has
been engineered to help eliminate viruses, bacteria, mold, smoke, chemical
odors, and volatile organic compounds (VOCs) from the entire structure by
using the air conditioner or hot-air heating system to circulate purified air
within the conditioned space.
The QwikPure TripleGuard™ unit is easily installed into the ductwork of air
conditioning and heat systems (HVAC systems) where most sick building problems
originate.
Unlike many air purifiers, QwikPure TripleGuard™ uses three methods to clean,
sanitize, and purify the air. The first stage is UV-C Light, which is lethal
to many viruses and bacteria by damaging their DNA and RNA. The second stage
is photocatalytic oxidation (PCO), which forms powerful hydroxyl radicals that
break down organic substances by oxidation. The final stage is an activated
carbon/potassium permanganate (AC/PP) purifier to ensure complete oxidation
and provide an additional level of sanitization. The result is a powerful
three-punch approach that reduces bacteria, viruses, and odors as well as VOCs
emitted from paints, cleaners, building materials, and cooking. Safe and ozone
free, the QwikPure TripleGuard™ UV-C bulbs are specially coated to avoid the
production of any ozone. Furthermore, any ozone in the air would be removed by
the PCO and AC/PP air cleaning stages.
Built to Last – Industrial-Grade Design
- Multiple voltage capability allows the system to operate on 120, 208, or 240 VAC single phase.
- Continuous operation is suggested, but the unit can also be activated when only the blower is operating.
- Dual lamps provide ample UV-C with individual bulb indicators to tell you when to change the lamps—typically, every year.
- UV-C bulbs are specially coated to prevent any ozone formation. (Ordinary UV-C bulbs can create harmful ozone).
- PCO surface is cleanable, allowing the catalyst to be renewed with simple cleaning (recommend cleaning when UV-C bulbs are changed).
Normally the AC/PP purifier would need to be changed frequently to treat the whole home, but the UV/PCO combination greatly reduces the load on the AC/PP purifier, allowing the purifier to clean the air for extended periods. The AC/PP purifier should be changed annually.
Installation Instructions
Step 1. Verify the contents of the package.
The QwikPure TripleGuard™ kit contains the following:
- QwikPure TripleGuard™ air sanitization unit for HVAC duct mounting
- Replaceable AC/PP purifier (packaged separately)
- Two replaceable UV-C bulbs (packaged separately)
- Mounting flange assembly (Interior flange, four wing nuts, two ¼-20 nuts and fender washers)
- Caution UV-C In Use Decal
- Next Service Date sticker` Two fuse assemblies with fuses
- One rubber grommet
- Installation and Operation Manual
- Warranty registration card
If you are missing any parts contact Mainstream Engineering Corp. for a replacement at 1-800-866-3550 or 1-321-631-3550.
Step 2. Install UV-C bulbs and purifier
Install UV-C bulbs
-
Two replaceable UV-C bulbs are shipped with this unit. Carefully remove bulbs from their packaging.
-
Insert one bulb into each of the two bulb sockets located behind the front facing plate.
Handle carefully, from the bulb base, and avoid touching the glass. -
Slide the socket end of each bulb, through the oval opening in the back plate. Align and insert bulb socket pins with the socket pin holes at the front plate of the unit.
-
Apply firm gentle pressure to ensure full socket connection. Snap the bulb into the clear bulb retainer clip.
Install Purifier
-
This unit ships with one replaceable activated carbon/potassium permanganate purifier (AC/PP).
Locate the purifier and remove from its protective package. -
Remove six screws to permit AC/PP access plate removal, exposing the purifier opening and track.
-
Insert the AC/PP purifier into the track and slide all the way to the back of the unit. (There is no preferred flow direction for the purifier)
-
Replace the AC/PP access plate and six screws.
NOTE: Purifier is packaged separately to prevent exposure and damage during shipping.
Step 3. Determine the Mounting Location
Ensure the ductwork in the mounting location is deep-enough to accommodate the length of the unit.
The QwikPure TripleGuard™ purifier can be mounted horizontally, vertically, or
at any angle in-between. Do not install upside down, air flow must pass thru
the AC/PP purifier last.
Maximum performance is achieved when the QwikPure TripleGuard™ is located in
the air plenum just after (downstream of) the air handling unit. This is the
supply or post-evaporator air side of the air handler, not the return air
side. This unit does not replace the traditional air filter located on the
return side of the air handler whose purpose is to filter out particulate
matter and dust.
Because you will be cutting into the supply duct, we recommend mounting
QwikPure TripleGuard™ Air Purifier in the supply duct, not the sheet metal of
the air handler to avoid any potential damage to components inside the air
handler. When considering a mounting location, consider the power source
location—typically the power source is the air handler itself.
The QwikPure TripleGuard™ Air Purifier can operate on any AC voltage between
120 and 240 volts. Typically, residential AC air handlers and heat pumps
operate on 240 Volts AC and furnaces operate on 120 VAC. The electrical
connection should be performed following the local electrical codes. If unsure
about the local electrical codes, then consult a local licensed electrician.
Fuses are suppled to provide over-current protection. When considering a
mounting location, remember the AC/PP oxidizing purifier is to be changed
annually, so ensure there is ample space to slide the purifier out of the
QwikPure TripleGuard™ without any obstructions limiting the travel.
Ideally, the QwikPure TripleGuard™ Air Purifier should be located in the
center of the air flow of the duct, that is midway between the sides of the
duct.
The QwikPure TripleGuard™ must be installed into the ductwork in a location
that cannot be viewed by anyone during routine operation of the system or
during air filter changing. LOOKING DIRECTLY AT AN ILLUMINATED UNIT WILL CAUSE
DAMAGE TO EYES. The GREEN LED indicates the unit is powered and operating
properly and the two ORANGE LEDs indicate each UV-C bulb is operating
properly. There is never a need to look at the UV-C bulbs during operation.
Step 4. Install the Mounting Bracket
If the QwikPure TripleGuard™ unit is to be installed against a sheet metal
surface, skip to Step 5.
If the QwikPure TripleGuard™ is to be installed into duct board, then the
mounting flange must be installed first, to provide a solid anchoring method
for the QwikPure TripleGuard™ unit.
- a. Prepare to cut an opening in the duct board for insertion of the QwikPure TripleGuard™ unit.
- Position and hold the mounting flange against the duct board (studs pointing toward the duct board), and orient to preferred mounting point.
- Apply enough pressure to cause the mounting plate studs to dent/mark the duct board to allow accurate holes to be created.
- Remove the mounting flange temporarily. Locate the stud marks and use a drill, a sharp pointed object, or the threaded studs of the mounting flange to punch the holes in the duct board for the flange mounting studs.
- Align the mounting plate studs with the created holes and insert until the mounting plate is flush with the duct board.
- Cut an opening along the inside opening of the flange as shown in Figure 1. Before cutting, ensure the QwikPure TripleGuard™ will fit in the planned space.
- b. Insert the mounting flange through the opening in the duct board, locate the mounting flange on the inside of the duct board, align the mounting flange studs to holes, push studs through and bolt the mounting flange to the duct board using the center ¼-20 threaded studs, washers and ¼-20 nuts. Use a wrench to tighten both threaded fastners so the duct board is slightly compressed and the mounting flange is secure.
Step 5. Install the QwikPure TripleGuard™ Air Purifier
If mounting on a duct board surface:
Insert the QwikPure TripleGuard™ into the duct, using the four remaining
mounting studs to locate the QwikPure TripleGuard™ unit. Secure the Qwik Pure
Triple Guard™ to the mounting flange studs with the four wing nuts supplied.
If mounting on a metal surface:
- a. Hold the exterior mounting flange against the metal duct and cut an opening along the inside opening of the flange. Before cutting, make certain the QwikPure TripleGuard™ will fit in the planned space. (see Figure 1). Cut an opening along the inside opening of the flange.
- b. Discard the mounting bracket. Using self-tapping sheet metal screws, secure the QwikPure TripleGuard™ directly to the sheet metal surface.
Step 6. Connect to a Power Source
For optimal performance and maximum bulb life, the QwikPure TripleGuard™
should be operated continuously. However, using a relay (activated by the G
and common wires), the QwikPure TripleGuard™ can also be operated only when
the indoor blower is operating.
The QwikPure TripleGuard™ can be connected to any AC power source between 120
and 240 VAC. We suggest that the power be drawn from the air handler or
furnace power source downstream of the air handler or furnace breaker however
any AC power source from 120 to 240 VAC can be used.
The electrical connection should be performed by a licensed electrician and
conform to local electrical codes.
A rubber grommet is provided. Use the grommet to seal and protect the power
cord as it passes through the sheet metal of the air handler. The securing
strap is used to prevent any strain on the power cord. Drill a ½” diameter
hole to accept the grommet into the sheet metal.
The power source must be fused. Two fuse cases with fuses are supplied. If
connecting to 120 VAC, then only one fuse assembly on the hot (black)wire is
needed. However, if connecting to 240 VAC both lines are hot, so a fuse is
provided for each lead. Connect these fuses between the air handler power
source and the QwikPure TripleGuard™ power lead, downstream of any air handler
disconnect.
Ensure the green ground wire is properly grounded.
Step 7. Verify proper operation
- After successfully completing the previous steps, turn the unit on.
- The GREEN LED should be illuminated indicating proper power to the unit.
- The two ORANGE LEDs should be illuminated indicating both UV-C bulbs are operating properly.
Step 8. Educate the Homeowner
Complete and attach the Next Service Date sticker on the access cover with a
date approximately 12 months from the install date for both the UV-C bulbs and
the AC/PP purifier.
Warn the homeowner to never take the unit out of the duct work without first
turning the power switch off. Explain that all service must be performed by a
licensed HVAC professional or the warranty will be voided.
Explain the danger of looking at the light emitted from the QwikPure
TripleGuard™ unit.
Show the homeowner the GREEN LED and ORANGE LEDs, and explain that the LEDs
should be checked periodically, ideally with every air filter change or at
least a few times a year. Explain that they need to call for service if any of
these lights are off.
**Replacing the Activated Carbon/Potassium Permanganate (AC/PP) Purifier
**
This final stage of air purification should be changed annually.
Step 1. Check the status of the LED indicator lamps
Verify the unit is properly operating by verifying the GREEN LED and two
ORANGE LEDs are illuminated.
If the GREEN LED is not illuminated, there is either no electrical power being
supplied to the unit (check the fuses), or the electronics control module unit
has failed and must be
replaced. No serviceable electrical components are within the QwikPure
TripleGuard™ unit’s electronic control module. If power to the unit has been
verified and the GREEN LED is not illuminated, contact Mainstream Engineering
for replacement parts 1-800-866-3550 or
1-321-631-3550.
If one or both of the ORANGE LEDs are not illuminated and the GREEN LED is
illuminated, one or both of the bulbs have failed and BOTH bulbs should be
replaced. Even if only a single bulb has failed, always replace both bulbs.
The life of each bulb is very similar and the remaining bulb is likely to fail
soon. Replacing both bulbs at the same time helps you avoid unnecessary call-
backs. Replacement bulbs are sold as a set, order part number QT2732.
Step 2. Turn power off
Using the switch on the QwikPure TripleGuard™ turn the power off. All LEDs should go off.
Step 3.
Remove the AC/PP access plate by removing the six machine screws with a Philips screwdriver.
Step 4. Replace the AC/PP purifier and complete the installation.
- a. Insert a new AC/PP purifier (part number QT2734) into the QwikPure TripleGuard™ by sliding the unit into the guides.
- b. Replace the AC/PP access cover.
- c. Install a new Next Service sticker with the replacement date for the AC/PP purifier appropriately 12 months from today’s date. Transfer the bulb replacement date to the sticker as well.
- d. Turn power back on and check for proper function. All three LEDs should be illuminated.
Replacing the UV-C Lights
The UV-C lights are the first stage of air purification and should be changed at least once a year.
Step 1. Check the status of the LED indicator lamps
Verify the unit is properly operating, by checking the Green LED is
illuminated.
If the GREEN LED is not illuminated, there is either no electrical power being
supplied to the unit (check the fuses) or the electronics control module unit
has failed and
must be replaced. No serviceable electrical components are within the QwikPure
TripleGuard™ unit’s electronic control module. If power to the unit has been
verified, contact Mainstream Engineering for support at
1-800-866-3550 or
1-321-631-3550.
If the Next Service sticker is indicating that it is time to replace the UV-C
bulbs, change them even if they are still working as indicated by the ORANGE
LEDs being illuminated. If one or both of the orange LEDs are not illuminated
and the GREEN LED is illuminated, one or both of the bulbs have failed and
BOTH bulbs should be replaced. Always replace both bulbs. The life of each
bulb is similar and the remaining bulb is likely to fail soon. Replacing both
bulbs at the same time will help you avoid unnecessary call-backs. Replacement
bulbs are sold as a set, order part number QT2732.
Step 2. Turn power off and disconnect electric power
Turn power off at the breaker powering the QwikPure TripleGuard™ (not at the switch on the unit). All LEDs will go off when the power is off. Unplug the power lead from the electronics control module.
Step 3.
Remove the AC/PP unit from the QwikPure TripleGuard™, following the Instructions for AC/PP removal (described previously).
Step 4. Remove QwikPure TripleGuard™ unit from the ductwork.
If the QwikPure TripleGuard™ is installed directly into a sheet metal duct,
remove the retaining sheet metal screws, and carefully slide the unit out of
the duct.
If the QwikPure TripleGuard™ is installed onto a fiber duct board, remove the
four wing nuts and carefully slide the unit out of the duct.
Step 5. Remove the UV-C Bulbs
Carefully remove the two UV-C bulbs from the QwikPure TripleGuard™ unit by sliding them out the end of the unit, through the clearance holes. Dispose of these bulbs in the same manner as any other fluorescent bulb. These bulbs contain mercury and must be disposed of properly.
Step 6. Clean the PCO surfaces
Use a clean damp cloth to clean dust and debris from all surfaces of the QwikPure TripleGuard™ unit, including the photocatalytic oxidation surfaces.
Step 7. Install new UV-C bulbs
Carefully insert two new QwikPure TripleGuard™ UV-C bulbs into the unit by
sliding them in through the end of the unit, through the clearance holes.
Ensure the bulbs are
properly seated into the bulb sockets. Only use QwikPure TripleGuard™ UV-C
bulbs (part number QT2732), because they contain a unique anti-ozone coating
and the power supply has been specially designed to soft-start these bulbs for
increased life. Using the wrong bulbs damages the power electronics, the
bulbs, and system performance.
Step 8. Reinstall the QwikPure TripleGuard™ Air Purifier
If the QwikPure TripleGuard™ Air Purifier was mounted on a metal surface, use
the existing self-tapping screws to secure the unit directly to the sheet
metal surface.
If the QwikPure TripleGuard™ Air Purifier was mounted on a duct board surface,
insert the unit into the duct, using the mounting studs to locate and hold the
unit. Secure with the wing nuts.
Step 9. Replace the AC/PP purifier
Always use a fresh new AC/PP purifier (part number QT2734) after replacing UV-C bulbs. Follow the instructions for replacing the AC/PP purifier.
Step 10. Reconnect power source and verify operation
Replace the power plug into the electronics control module, and turn power
back on. Verify the switch on the electronics control module is on.
The green LED is illuminated when the unit has proper power, and the two
orange LEDs are illuminated when both UV-C bulbs are operating properly. If
the Orange LEDs are not illuminated, recheck that the bulbs are properly
seated in the sockets (Step 7). If the problem cannot be resolved, contact
Mainstream Engineering for support at
1-800-866-3550 or
1-321-631-3550.
Step 11. Re-educate the homeowner
Complete and attach the Next Service Date sticker on the access cover, with a
date approximately 12 months from today’s date for the next UV-C bulb change
and the updated date for the AC/PP purifier change.
Warn the homeowner to never take the unit out of the duct work, without first
turning the power switch off. Explain that all service must be performed by a
licensed HVAC professional or the warranty will be voided.
Explain the danger of looking at the light emitted from the QwikPure
TripleGuard™ unit
Show the homeowner the Green LED and Orange LEDs, and explain that they should
be checked ideally with every air filter change or at least a few times a
year. Explain that they need to call for service if any of these lights are
off.
6 Year Limited Product Warranty
Mainstream Engineering Corporation (“Company”) expressly warrants only to the
original end-use purchaser; that, for a period of six (6) years from the
initial start-up by the installer of the QWIKPURE TRIPLEGUARD™ UV Air
Sanitizer (the “Product”) will be reasonably free of defects in materials and
workmanship. This Limited Warranty only applies to Company’s Products which
are used, stored, handled, and installed in the manner recommended by Company.
The Company will be the sole Party to make any determination of warranty
claims.
Company will, at its option, replace Product without charge within one (1)
year, or refund the cost of the Product, if the Product fails or does perform
as warranted solely due to a manufacturing defect within the warranty period,
subject to the exclusions set forth in this Limited Warranty. Repair or
replacement during this one (1) year warranty shall not include labor and any
costs associated with removal, repair or replacement of any fixtures,
hardware, decorative treatment, or any shipping costs to return the Product to
the Company or to send either the original or new Product back to the
recipient. During the entire one (1) year warranty, Company’s obligation as to
repair or replacement shall further be limited to repair or replacement with
the styles, models, products, and colors of the Product that are available at
the time of the repair or replacement, and shall be limited to the repair or
replacement of only the specific Product that fails due to a manufacturing
defect. Any repaired or replaced product shall also remain subject to the
original one (1) year warranty from the date of the original installation of
the Product, and any repair or replacement shall not extend the original
warranty period in any manner or start a new warranty period.
After the first one (1) year period of this Limited Warranty has past, for the
subsequent five one (1) year periods, the Company will provide a rebate of a
percentage of the original purchase price as a credit toward a new Product.
For the first subsequent one (1) year period, the Company will provide the
original end use purchaser a rebate credit of 85% of the original purchase
price to be applied to the purchase of a new Product. For the second
subsequent one (1) year period, the Company will provide the original end use
purchaser a rebate credit of 66% of the original purchase price to be applied
to the purchase of a new Product. For the third subsequent one (1) year
period, the Company will provide the original end use purchaser a rebate
credit of 50% of the original purchase price to be applied to the purchase of
a new Product. For the fourth subsequent one (1) year period, the Company will
provide the original end use purchaser a rebate credit of 33% of the original
purchase price to be applied to the purchase of a new Product. For the fifth
subsequent one (1) year period, the Company will provide the original end use
purchaser a rebate credit of 15% of the original purchase price to be applied
to the purchase of a new Product.
You may obtain coverage under this Limited Warranty by providing Company with
proof of purchase. For service under this Limited Warranty, you must notify
Mainstream Engineering Corporation Customer Service Department at
1-800-866-3550 or
info@qwik.com.
Disclaimer of Warranties
Company’s Products must be stored, handled, installed, used and maintained in accordance with instructions provided by Company, and this Limited Warranty is conditioned upon compliance with all such instructions. Additionally, this Limited Warranty is conditioned upon submission of photographs evidencing the proper installation of the Product in the ductwork away from the air handler. Copies of the Company’s use guide; care guide; instruction manual, installation or fabrication guides, are available from the dealer, distributor etc., or from the Company at the address listed below. You may also obtain this/these materials on the Company’s website at www.mainstream- engr.com.
This Limited Warranty does not cover defects caused by:
- non-compliance with Company’s use guide, care guide, instruction manual. Such failures include, but are not limited to, exposure to physical abuse, including, but not limited to impact, puncturing, dropping the Product, moving the Product once the Product has been installed, chemical abuse (e.g., harsh cleansers and solvents), thermal abuse or shock (e.g. excessive heat or cold), or misuse;
- improper storage, installation, handling, use and/or fabrication of the Product;
- damage not resulting from manufacturing defects that occur while the Product is in the customer’s possession;
- unreasonable or unintended use of Product;
- products installed with known or visible manufacturing defects at the time of installation, including, but not limited, to color variances;
- minor conditions such as stains, scratches, etc.;
- failure or dissatisfaction with appearance of styling or coloring.
Any information or suggestion by Company with respect to the Products
concerning applications, specifications, or compliance with codes and
standards is provided solely for your convenient reference and are made
without any representation as to accuracy or suitability. You must verify and
test the suitability of any information with respect to the Products for your
specific application.
THE WARRANTIES SET FORTH HEREIN ARE THE ONLY WARRANTIES MADE BY COMPANY IN
CONNECTION WITH THESE PRODUCTS. COMPANY CAN NOT AND DOES NOT MAKE ANY IMPLIED
OR EXPRESS WARRANTIES WITH RESPECT TO THE PRODUCT, AND DISCLAIMS ALL OTHER
WARRANTIES, INCLUDING, BUT NOT LIMITED TO, ANY WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. PRODUCTS SOLD BY COMPANY ARE SOLD ONLY TO
THE SPECIFICATIONS SPECIFICALLY SET FORTH BY COMPANY IN WRITING. OTHER THAN
THE LIMITED WARRANTY SET FORTH HEREIN, COMPANY MAKES NO OTHER WARRANTIES,
EXPRESS OR IMPLIED. COMPANY’S SOLE OBLIGATION UNDER THIS WARRANTY SHALL BE
REPAIR OR REPLACEMENT OF NON-CONFORMING PRODUCTS, OR AT THE OPTION OF COMPANY,
RETURN OF THE PRODUCT AND A REFUND OF THE PURCHASE PRICE. BUYER ASSUMES ALL
RISK WHATSOEVER AS TO THE RESULT OF THE USE OF THE PRODUCTS PURCHASED, WHETHER
USED SINGULARLY OR IN COMBINATION WITH ANY OTHER PRODUCTS OR SUBSTANCES.
Limitation of Liability
No claim by the buyer/owner of any kind, including claims for indemnification,
shall be greater in amount than the purchase price of the Products in respect
to which damages are claimed. IN NO EVENT SHALL COMPANY BE LIABLE TO
BUYER/OWNER IN TORT, CONTRACT OR OTHERWISE, FOR ANY SPECIAL, INDIRECT,
INCIDENTAL, CONSEQUENTIAL, RELIANCE, STATUTORY, SPECIAL, PUNITIVE OR EXEMPLARY
DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOST PROFITS, LOSS OF USE, LOSS OF
TIME, LOSS OF REVENUES, INCONVENIENCE, LOSS BUSINESS OPPORTUNITIES, DAMAGE TO
GOOD WILL OR REPUTATION, OR LOSS OF DATA, EVEN IF ADVISED OF THE POSSIBILITY
OF SUCH DAMAGES OR SUCH DAMAGES COULD HAVE BEEN REASONABLY FORESEEN, IN
CONNECTION WITH, ARISING OUT OF, OR AS A RESULT OF, THE SALE, DELIVERY,
SERVICING, USE OR LOSS OF USE OF THE PRODUCTS SOLD HEREUNDER, OR FOR ANY
LIABILITY OF BUYER TO ANY THIRD PARTY WITH RESPECT THERETO.
Contact Information
Any question concerning this warranty should be addressed to:
Mainstream Engineering Corporation, Attn: Customer Service • Address: 200
Yellow Place, Rockledge, FL 32955
Phone: 321-631-3550, Email:
info@qwik.com • Website address:
www.qwik.com
- 200 Yellow Place
- Rockledge, Florida 32955
- CONTACT
- info@qwik.com
- www.qwik.com
- CALL FOR SUPPORT
- 1-800-866-3550 or 1-321-631-3550
QwikProducts™, QwikPure TripleGuard™ are trademarks and Mainstream Engineering Corporation® is a registered trademark of Mainstream Engineering Corporation. Rockledge, Florida 32955, 321-631-3550
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>