DANIA 429920 15kW Electric Space Heater Instruction Manual

June 5, 2024
DANIA

Electric space heater Dania
15kW
Manual instruction

DANIA 429920 15kW Electric Space Heater -

Heater connection:

Connect space heater to mains supply through the plug. Be sure to mount plug correctly. The heater is designed to be powered by 400V/50Hz mains. The cable isn’t included.
ATTENTION! The power outlet must be equipped with a suitable grounding.

Heater installation :

the heater should be installed in a place where are no present flammable materials and no fire hazards occur. The place where the risk of flooding or splashing with water occurs is unsuitable. The device should be placed at a minimum 50cm distance from the wall to ensure proper airflow. When mounting the device on a shelf or with wall mounting, place the heaters not lower than 180 cm from the floor, and not less than 50 cm distance from the sidewalls and the ceiling. Keep a distance of 15 cm from the back of the heater to the mounted wall.

DANIA 429920 15kW Electric Space Heater - 2

Control panel:

  1. Power/function selector switch
  2. Room thermostat regulator
  3. RESET button

Operation:

switch on the unit by adjusting the function selector switch (1) to the required position:

  1. heating 15kW
  2. heating 7,5kW
  3. fan mode
  4. switch off

The space heater is equipped with an adjustable thermostat. To set the required temperature turn the thermostat regulator (2), and the heater runs automatically.

When room temperature set by the thermostat regulator (2) is reached, heating elements will be switched off. Fan continues working. When room temperatures drop down, units start to heat automatically.
The heater in fan mode function selector switch position) forces the circulation of unheated air. The heating elements will not be switched on, regardless of thermostat regulator (2) settings.

Switching off:

Before switching off the heater, it is recommended to cool down heating elements by turning function selector (1) to fan mode for a couple of minutes in order to cool the unit before switching off or before interrupting the main supply.
Then the heater can be turned off by turning the function selector switch (1) to the position .
Inelco Dania 15kW heaters are protected against overheating and damage by a thermal fuse. When the temperature on the heater outlet exceeds the safety level, the thermostat will turn off the heating elements. The fan will be working. The most common reason for thermal fuse activation is the loss of the power supply while the heater is on or switching off without cooling down during the operation of the heater.

To deactivate thermal protection follow the instructions below:

  1. Cooldown the heater- wait a couple of minutes.
  2. Press the RESET button until the „click” noise will be heard.
  3. The heater is ready to be used.

DANIA 429920 15kW Electric Space Heater - 7

Maintenance

Regularly wipe the enclosure using a soft sponge or fabric. For very dirty parts, use a sponge wetted with lukewarm water and a mild detergent, then dry using a clean fabric.
Keep air inlet and fan-free from dust and dirt. To clean inner parts, gently blow compressed air through the air inlet.
Regularly inspect the power cable: if worn, cracked, damaged, or if necessary have it replaced with a new one. Before storing the heater, make sure it is perfectly cool and dry. Cover the unit with a plastic bag. Store in an original (or similar) box in a dry, ventilated place.

WARNING!
Do not cover — the danger of fire!
Do not place the heater where inflammable materials may be placed on or near the heater!
Do not cover the heater, the heater must not be exposed to excessive dust and humidity!
Do not use the heater outdoors in rainy weather!
Do not place the heater directly under a mains outlet!
Do not use the heater close or near to a bath, shower, or swimming pool! When the heater is not in use, it must be removed from fire hazardous rooms and should be stored in a dust-free room!
The space heater must only be disassembled by the manufacturer or a qualified service engineer!
This appliance is not designed for use by young children or people who cannot read or understand the manual unless they are under the supervision of a responsible person to ensure that they can use the heater safely. Store and use heater out of the reach of children, and ensure that children cannot play with it.

Guarantee
KEEP VALID RECEIPT OR GUARANTEE CARD
To obtain guarantee cover within the guarantee period, it is necessary that either a valid receipt or the

This symbol on Inelco product or its packaging means that the product should not be disposed of with your other household waste. It is your responsibility to dispose of your waste equipment separately from the municipal waste stream.
The correct disposal of your end-of-life equipment will help prevent potential negative consequences for the environment and human health.

The manufacturer reserves the right to make changes and/or improvements in designs & dimensions & manual instruction without prior notice and without incurring obligation.

Technical specifications

Output [kW]| 7,5/15
Output [kcal/h]| 6450/12900
Output [kJ/h]| 27000/54000
Mains voltage [V]| 3×400
Max. mains current [A| 22.
Fan diameter [mm]| 300
Air flow [m3/h]| 1300
Dimentions (LxWxH) [mm]| 600x320x430
Weight [kg]| 16
Protection class IP| 44

Manufacturer’s Declaration of Conformity
We, the undersigned
INELCO HEATERS A/S – Industrivej 3 – DK-9690 Fjerritslev
ertify that the product.

Space Heater

Type
1650
1652
1656| Rating
15 kW – 3×400 V – 50 Hz
15 kW – 3×400 V – 50 Hz
15 kW – 3×400 V – 50 Hz
---|---

has been designed and manufactured in accordance with the specifications of the following:

Directive
MSD 89/392/EEC – 91/368/EEC, 93/44/EEC, 93/68/ EEC, artikel 6
LVD 2014/35/EU
EMC 20141301EU| Standard
EN 292-1, EN 292-2
EN 60 335-2-30
EN 55014-1. EN 55014-2, EN 61000-3-2, EN 61000-3-3
---|---

Notes __

Sign
Director

DANIA 429920 15kW Electric Space Heater - 1http://www.inelco-heaters.com

www.inelco-heaters.com
e-mail: [email protected]
+48 91 578 83 90
INELCO Polska Sp. z o.o., ul. Pyrzycka 44, PL 74-240 Lipiany, Poland

Date: 01.01.2017

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals