HT FLASHMETER Handheld Multimeter Digital Waterproof User Manual
- June 5, 2024
- HT
Table of Contents
User manual
PRECAUTIONS AND SAFETY MEASURES
The instrument has been designed in compliance with directive IEC/EN61010-1 relevant to electronic measuring instruments. For your safety and in order to prevent damaging the instrument, please carefully follow the procedures described in this manual and read all notes preceded by symbols with the utmost attention. Before and after carrying out measurements, carefully observe the following instructions:
- Do not carry out any measurements in humid environments
- Do not carry out any measurements in case gas, explosive materials or flammables are present, or in dusty environments
- Avoid any contact with the circuit being measured if no measurements are being carried out.
- Avoid contact with exposed metal parts, unused measuring probes, circuits, etc.
- Do not carry out any measurement in case you find anomalies in the instrument such as deformation, breaks, substance leaks, absence of display on the screen, etc.
- Pay special attention when measuring voltages higher than 20V, since the risk of electrical shock exists
In this manual, and on the instrument, the following symbols are used:
Warning: observe the instructions given in this manual; improper use
could damage the instrument or its components.
High voltage danger: electrical shock hazard.
Double-insulated meter
AC voltage
**** DC voltage
1.1. PRELIMINARY INSTRUCTIONS
- This instrument has been designed for use in environments of pollution degree 2.
- It can be used for VOLTAGE measurements on installations in CAT IV 600V.
- We recommend following the normal safety rules devised to protect the user against dangerous currents and the instrument against incorrect use.
- Only the leads supplied with the instrument guarantee compliance with the safety standards. They must be in good condition and replaced with identical models, when necessary.
- Do not test circuits exceeding the specified voltage limits.
- Do not perform any test under environmental conditions exceeding the limits indicated in § 7.1.1 and 7.2.1.
- Check that the battery is correctly inserted.
- Before connecting the test leads to the circuit to be tested, make sure that the rotary switch is correctly set.
- Make sure that the LCD display and the rotary switch indicate the same function.
1.2. DURING USE
Please carefully read the following recommendations and instructions:
CAUTION
**** Failure to comply with the caution notes and/or instructions may damage
the instrument and/or its components or be a source of danger for the
operator.
- When the instrument is connected to the circuit being measured, do not touch any unused terminal.
- While measuring, if the value or the sign of the quantity being measured remains unchanged, check if the HOLD function is enabled.
1.3. AFTER USE
- When measurements are completed, switch off the instrument by pressing the ON/OFF key.
- If the instrument is not to be used for a long time, remove the batteries.
1.4. DEFINITION OF MEASUREMENT (OVERVOLTAGE) CATEGORY
Standard “IEC/EN61010-1: Safety requirements for electrical equipment for
measurement, control, and laboratory use, Part 1: General requirements”,
defines what measurement category, commonly called overvoltage category, is. §
6.7.4: Measured circuits, reads:
(OMISSIS)
Circuits are divided into the following measurement categories:
-
Measurement category IV is for measurements performed at the source of the low-voltage installation.
Examples are electricity meters and measurements on primary overcurrent protection devices and ripple control units. -
Measurement category III is for measurements performed on installations inside buildings.
Examples are measurements on distribution boards, circuit breakers, wiring, including cables, bus bars, junction boxes, switches, socket-outlets in the fixed installation, and equipment for industrial use and some other equipment, for example, stationary motors with a permanent connection to fixed installation. Measurement category II is for measurements performed on circuits directly connected to the low-voltage installation.
Examples are measurements on household appliances, portable tools, and similar equipment. -
Measurement category I is for measurements performed on circuits not directly connected to MAINS.
Examples are measurements on circuits not derived from MAINS and specially protected (internal) MAINS-derived circuits. In the latter case, transient stresses are variable; for that reason, the standard requires that the transient withstand capability of the equipment is made known to the user.
GENERAL DESCRIPTION
The instrument carries out the following measurements in the full Auto range:
- DC voltage
- AC TRMS voltage
- Detection of AC voltage without contact
- Resistance and Continuity test
According to the quantity present at the input, the instrument automatically switches between voltage and resistance measurement. The instrument is also provided with the following function keys: AutoHold/ to enable freezing the measured value on the display and to activate the white light torch, ON/OFF, and a central V/Ω/ to manually select resistance measurement and continuity test. The selected quantity appears on the LCD display with the indication of the measuring unit and of the enabled functions. The instrument is provided with a display backlight function which automatically deactivates after approximately 2 minutes of idling. The instrument is also equipped with an Auto Power OFF device which automatically switches it off approx. 15 minutes after the last time the instrument was used.
2.1. MEASURING AVERAGE VALUES AND TERMS VALUES
Measuring instruments of alternating quantities are divided into two big
families:
- AVERAGE-VALUE meters: instruments measuring the value of the sole wave at the fundamental frequency (50 or 60 Hz).
- TRMS (True Root Mean Square) VALUE meters: instruments measuring the TRMS value of the quantity being tested.
With a perfectly sinusoidal wave, the two families of instruments provide
identical results.
With distorted waves, instead, the readings shall differ. Average-value meters
provide the RMS value of the sole fundamental wave; TRSM meters, instead,
provide the RMS value of the whole wave, including harmonics (within the
bandwidth of the instrument). Therefore, by measuring the same quantity with
instruments from both families, the values obtained are identical only if the
wave is perfectly sinusoidal. In case it is distorted, TRMS meters shall
provide higher values than the values read by average-value meters.
2.2. DEFINITION OF TRUE ROOT MEAN SQUARE VALUE AND CREST FACTOR
The root means the square value of current is defined as follows: “In a time
equal to a period, an alternating current with a root means the square value
of 1A intensity, circulating on a resistor, dissipates the same energy that,
during the same time, would be dissipated by a direct current with an
intensity of 1A”. This definition results in the numeric expression:
The root means the square value is indicated with the acronym RMS.
The Crest Factor is defined as the relationship between the Peak Value of a signal and its RMS value: This value changes with the signal waveform, for a purely sinusoidal wave it is 2 =1.41. In case of distortion, the Crest Factor takes higher values as wave distortion increases.
PREPARATION FOR USE
3.1. INITIAL CHECKS
Before shipping, the instrument has been checked from an electric as well as
mechanical point of view. All possible precautions have been taken so that the
instrument is delivered undamaged. However, we recommend generally checking
the instrument in order to detect possible damage suffered during transport.
In case anomalies are found, immediately contact the forwarding agent.
We also recommend checking that the packaging contains all components
indicated in § 7.3.1. In case of discrepancy, please contact the Dealer. In
case the instrument should be returned, please follow the instructions given
in § 8.
3.2. INSTRUMENT POWER SUPPLY
The instrument is supplied with 2×1.5V alkaline batteries type AAA IEC LR03,
included in the package. When the battery is flat, the symbol “ ” appears on
the display. To
replace/insert the batteries, see § 6.2.
3.3. STORAGE
In order to guarantee precise measurement, after a long storage time under
extreme environmental conditions, wait for the instrument to come back to
normal operating conditions (see § 7.2.1).
NOMENCLATURE
4.1. DESCRIPTION OF THE INSTRUMENT
Fig. 1 : Description of the instrument
4.2. DESCRIPTION OF THE SYMBOLS SHOWN ON THE DISPLAY
CAPTION:
- White-light torch
- NCV sensor
- Detector of AC voltage without contact
- LCD display
- ON/OFF key
- AutoHold / key
- V/Ω / key
- Input terminal COM
- Input terminal V/Ω/
Fig. 2 : Description of the symbols shown on the display
CAPTION:
- Activated white-light torch
- Active A HOLD function
- Auto Power Off (APO)
- Activation of continuity test
- Presence of high voltage
- Measuring unit
- DC voltage
- LCD display
- AC voltage
- Low battery symbol
4.3. DESCRIPTION OF FUNCTION KEYS
4.3.1. ON/OFF key ( )
Pressing the key allows turning on the instrument. Press and hold the key for
approx. 1s to turn off the instrument.
4.3.2. AutoHold/
Pressing the AutoHold/ key allows activating/deactivating the built-in
white-light torch (see Fig. 1 – part 1) and the symbol appears on the
display. Press and hold the AutoHold/ key for approx. 1s to
activate/deactivate the Auto HOLD function. The symbol “A HOLD” appears on the
display and the buzzer beeps twice in a short time. With the activated Auto
HOLD function, the instrument automatically freezes the measured value on
the display when the input signal is steady (3 samplings with a maximum
difference of 10% between the highest and the lowest value). The instrument
automatically quits the function after approx. 30s seconds.
4.3.3. key
CAUTION
- The instrument switches on in Ω mode.
- The instrument automatically switches to VAC or VDC if the following voltages are detected: VAC > ca. 1.5V; VDC > ca. 1.0V
- The instrument automatically switches to Ω mode with the following measured voltages: VAC and VDC < ca. 0.6V
- Press the V/Ω/ key to manually select resistance measurement and continuity test.
4.3.4. Detection of AC voltage without contact
The instrument allows detecting the presence of AC voltage without contact by using the NCV sensor found on the upper part (see Fig. 1 – part 2).
- Switch on the instrument by pressing the ON/OFF key.
- Bring the NCV sensor closer to the potential AC source.
- If the red detector turns on (see Fig. 1 – part 3), AC voltage is present.
4.3.5. Auto-Power-Off function
In order to preserve internal batteries, the instrument switches off
automatically approximately 15 minutes after it was last used. The symbol “ ”
identifies the Auto power-off function, which cannot be deactivated.
OPERATING INSTRUCTIONS
5.1.1. DC voltage measurement
CAUTION
The maximum input DC voltage is 600V. Do not measure voltages exceeding the
limits given in this manual. Exceeding voltage limits could result in
electrical shocks to the user and damage to the instrument.
Fig. 3 : Use of the instrument for DC voltage measurement
- Switch on the instrument by pressing the ON/OFF key. The measuring mode Ω is automatically selected and the indication “OL.” appears on the display.
- Insert the red cable into input terminal V/Ω/ and the black cable into the input terminal COM
- Position the red lead and the black lead respectively in the spots with the positive and negative potential of the circuit to be measured (see Fig. 3). The instrument automatically switches to DC voltage measurement for value > ca. 1.0V. The display shows the value of voltage.
- The message “O.L.” indicates that the value of DC voltage exceeds the maximum measurable value.
- When the symbol “-” appears on the instrument’s display, it means that voltage has the opposite direction with respect to the connection in Fig. 3.
- To use the AutoHOLD function, see § 4.3.2
5.1.2. AC voltage measurement
CAUTION
The maximum input AC voltage is 600V. Do not measure voltages exceeding the
limits given in this manual. Exceeding voltage limits could result in
electrical shocks to the user and damage to the instrument.
Fig. 4 : Use of the instrument for AC voltage measurement
-
Switch on the instrument by pressing the ON/OFF key. The measuring mode Ω is automatically selected and the indication “OL.” appears on the display.
-
Insert the red cable into input terminal V/Ω/ and the black cable into the input terminal COM
-
Position the test leads in the desired spots of the circuit to be measured (see Fig. 4).
The instrument automatically switches to AC voltage measurement for value > ca. 1.5V. The display shows the value of voltage. -
The message “O.L.” indicates that the value of AC voltage exceeds the maximum measurable value.
-
To use the AutoHOLD function and the NCV sensor, see § 4.3.2 and § 4.3.4
5.1.3. Resistance measurement
CAUTION
Before attempting any resistance measurement, cut off the power supply from
the circuit to be measured and make sure that all capacitors are discharged,
if present.
Fig. 5 : Use of the instrument for Resistance measurement
- Switch on the instrument by pressing the ON/OFF key. The measuring mode Ω is automatically selected and the indication “OL.” appears on the display.
- Insert the red cable into input terminal V/Ω/ and the black cable into input terminal COM.
- Position the test leads in the desired spots of the circuit to be measured (see Fig. 5). The display shows the value of resistance.
- The message “O.L.” indicates that the value of resistance exceeds the maximum measurable value.
- To use the AutoHOLD function, see § 4.3.2
5.1.4. Continuity test
CAUTION
Before attempting any resistance measurement, cut off the power supply from
the circuit to be measured and make sure that all capacitors are discharged,
if present.
Fig. 6: Use of the instrument for Continuity test
- Switch on the instrument by pressing the ON/OFF key. The measuring mode Ω is automatically selected and the indication “OL.” appears on the display.
- Press the V/Ω/ key until the symbol “ ” appears on the display.
- Insert the red cable into input terminal V/Ω/ and the black cable into input terminal COM.
- Position the test leads in the circuit to be measured (see Fig. 6). The continuity buzzer activates for R<40
- To use the AutoHOLD function, see § 4.3.2
MAINTENANCE
6.1. GENERAL INFORMATION
-
The instrument you purchased is a precision instrument. While using and storing the instrument, carefully observe the recommendations listed in this manual in order to
prevent possible damage or danger during use. -
Do not use the instrument in environments with high humidity levels or high temperatures. Do not expose to direct sunlight.
-
Always switch off the instrument after use. In case the instrument is not to be used for a long time, remove the battery to avoid liquid leaks that could damage the instrument’s internal circuits.
6.2. REPLACING THE BATTERY
When the LCD display shows symbol “ ”, batteries must be replaced.
CAUTION
Only expert and trained technicians should perform this operation. Before
carrying out this operation, make sure you have disconnected all cables from
the input terminals.
- Switch off the instrument by pressing the ON/OFF key.
- Loosen the battery compartment cover fastening screw and remove the cover.
- Remove the batteries and insert the same number of new batteries of the same type (see § 7.1.2), respecting the indicated polarity.
- Restore the battery compartment cover and fasten the relevant screw.
- Do not scatter old batteries into the environment. Use the relevant containers for disposal.
6.3. CLEANING THE INSTRUMENT
Use a soft and dry cloth to clean the instrument. Never use wet cloths,
solvents, water, etc.
6.4. END OF LIFE
WARNING: the symbol on the instrument indicates that the appliance, the battery, and its accessories must be collected separately and correctly disposed of.
TECHNICAL SPECIFICATIONS
7.1. TECHNICAL CHARACTERISTICS
Accuracy was calculated as ±[%reading + (num. digits*resol)] referred to
18°C÷28°C,<70%HR.
DC voltage (Auto range)
Range| Resolution| Accuracy| Input impedance|
Protection against overcharge
---|---|---|---|---
400.0V| 0.1V| ±(1.0%rdg+5digits)| >10MΩ| 600VDC/ACrms
600.0V
AC TRMS voltage (Auto range)
Range
| Resolution| *Accuracy () (40Hz ¸ 1kHz)| Input impedance**|
Protection against overcharge
---|---|---|---|---
400.0V| 0.1V| ±(1.0%rdg+5digits)| >9MΩ| 600VDC/ACrms
600.0V
(*) Accuracy specified from 5% to 100% of the measuring range.
Resistance (Auto range)
Range
| Resolution| Accuracy|
Protection against overcharge
---|---|---|---
40.0W| 0.1W| ±(2.0%rdg+18digits)| 600VDC/ACrms
400.0W| ±(2.0%rdg+10digits)
4.000kW| 0.001kW
40.00kW| 0.01kW
400.0kW| 0.1kW
Continuity test with buzzer
Function| Buzzer| Test current|
Protection against overcharge
---|---|---|---
| <40W| <0.3mA| 600VDC/ACrms
7.1.1. Reference standards
Safety:
EMC:
Insulation:
Pollution level:
Overvoltage category:
Max operating altitude:| IEC/EN61010-1
IEC/EN61326-1
double insulation
2
CAT IV 600V
2000m (6562ft)
---|---
7.1.2. General characteristics Mechanical characteristics
Size (L x W x H):
Weight (battery included):| 140 x 75 x 40mm (6 x 3 x 2in)
220g (8 ounces)
---|---
Power supply
Battery type:
Low battery indication:
Battery life:
Auto power off:| 2x 1.5V batteries type AAA IEC LR03
symbol “ ” on the display
approx. 80h (backlight ON), approx. 400h (backlight OFF)
after approx. 15 minutes’ idling
---|---
Display
Characteristics:
Out-of-range indication:
Sampling frequency:
Conversion:| ics: 4-digit LCD, 4000 dots, decimal sign and point with
backlight
“OL.” symbol on the display 3times/s
Conversion:
TRMS
---|---
7.2. ENVIRONMENT
7.2.1. Environmental conditions for use
Reference temperature:
Operating temperature:
Allowable relative humidity:
Storage temperature:
Storage humidity:
Mechanical protection:
Falling test:| 18°C ÷ 28°C (64°F ÷ 82°F)
0°C ÷ 50°C (32°F ÷ 122°F)
<75%HR
-20°C ÷ 60°C (-4°F ÷ 140°F)
<80%HR
IP67
2m (7ft)
---|---
This instrument satisfies the requirements of the Low Voltage Directive
2014/35/EU (LVD) and of EMC Directive 2014/35/EU
This instrument satisfies the requirements of European Directive 2011/65/EU
(RoHS) and 2012/19/EU (WEEE)
7.3. ACCESSORIES
7.3.1. Standard accessories
- Pair of leads with 2/4mm tip
- Batteries
- Carrying case
- User manual
ASSISTANCE
8.1. WARRANTY CONDITIONS
This instrument is warranted against any material or manufacturing defect, in
compliance with the general sales conditions. During the warranty period,
defective parts may be
replaced. However, the manufacturer reserves the right to repair or replace
the product.
Should the instrument be returned to the After-sales Service or to a Dealer, transport will be at the Customer’s charge. However, shipment will be agreed in advance. A report will always be enclosed to a shipment, stating the reasons for the product’s return. Only use the original packaging for shipment; any damage due to the use of non-original packaging material will be charged to the Customer. The manufacturer declines any responsibility for injury to people or damage to property.
The warranty shall not apply in the following cases:
- Repair and/or replacement of accessories and battery (not covered by warranty)
- Repairs that may become necessary as a consequence of incorrect use of the instrument or due to its use together with non-compatible appliances.
- Repairs that may become necessary as a consequence of improper packaging.
- Repairs may become necessary as a consequence of interventions performed by unauthorized personnel.
- Modifications to the instrument were performed without the manufacturer’s explicit authorization.
- Use not provided for in the instrument’s specifications or in the instruction manual.
The content of this manual cannot be reproduced in any form without the manufacturer’s authorization.
Our products are patented and our trademarks are registered. The manufacturer reserves the right to make changes in the specifications and prices if this is due to improvements in technology.
8.2. ASSISTANCE
If the instrument does not operate properly, before contacting the After-sales
Service, please check the conditions of batteries and cables and replace them,
if necessary. Should the instrument still operate improperly, check that the
product is operated according to the instructions given in this manual. Should
the instrument be returned to the After-sales Service or to a Dealer,
transport will be at the Customer’s charge. However, shipment will be agreed
in advance. A report will always be enclosed to a shipment, stating the
reasons for the product’s return. Only use the original packaging for
shipment; any damage due to the use of non-original packaging material will be
charged to the Customer.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>