OVERVIEW

  • Solid Red – Charger Fault. See display panel for details.

  • Flashing Amber – Caution. External error condition. See display panel for details.

  • Flashing Green – USB port active

  • Solid Green- Safe to remove USB flash drive.

  • Solid Blue – AC power available.

  • Flashing Green – Low state of charge.

  • Solid Green – High state of charge.

  • Flashing Green – High state of charge.

  • Solid Green- Charge complete.

Selecting a Charge Profile

  1. Disconnect AC input from the charger, or from the wall outlet. Wait 30 seconds for the input relay to open. (See Figure 1)
  2. While reconnecting the AC input, press and hold the Select Charge Profile Button. Hold the button until Error Indicator is on and Battery Charging Indicator starts flashing.
  3. Press and release the Select Charge Profile Button to advance through charging profiles loaded on the charger. The selected charging profile will be displayed up to three times (e.g. “P-0-1- 1” for Profile 11). (See Figure 2)
  4. Once desired to charge profile is displayed, press and hold the button for 10 seconds to Confirm selection and exit Profile Selection Mode. (See Figure 3)
  5. Press the Select Charge Profile Button to check that the desired profile is selected.