Description
This thermostat can be used to control an electric heating system such as a
baseboard heater, a radiant ceiling, a radiant floor, a convector, etc.
The thermostat cannot be used with the following:
- a resistive load under 2 A
- a resistive load over 12.5 A
- systems are driven by a contractor or a relay (inductive load)
- fan-equipped heating systems
- central heating systems
SUPPLIED PARTS
- One (1) thermostat
- Two (2) 6-32 mounting screws
- Two (2) solderless connectors
Installation
TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRIC
SHOCK.
Loosen the screw holding the control module to the base. The screw cannot be
completely removed. Lift the control module to remove it from the base.
Make the appropriate connections. Please note that the thermostat wires are non-polarized; either wire can be connected to either terminal.
Temperature Display and Setting
The thermostat normally displays the actual (ambient) temperature.
-
To view the setpoint temperature, press once on either of the temperature adjustment buttons.
The icon → appears during the setpoint display. -
To change the setpoint temperature, press the appropriate button until the desired value is displayed.
Power Outage
During a power outage, the setpoint is stored in memory.
Specifications
– Supply: 120/240 VAC, 50/60 Hz
– Minimum load: 2 A (resistive only)
500 W @ 240 VAC
250 W @ 120 VAC
– Maximum load: 12.5 A (resistive only)
3000 W @ 240 VAC
1500 W @ 120 VAC
– Display range: 32 to 122°F (0 to 50°C)
– Setpoint range: 40 to 85°F (5 to 30°C)
– Storage: -4 to 120°F (-20 to 50°C)
– Approval: c UL us
Troubleshooting
PROBLEM | SOLUTIONS |
---|---|
Thermostat is hot. | This is normal. Under normal operation, the thermostat |
housing can reach a temperature between 95°F (35°C) and 104°F (40°C).
Heater is always On.| The thermostat has not been correctly wired.
Thermostat indicates that heating is On, but the heater is not On.| The
thermostat has not been correctly wired.
Displayed tempera- ture is wrong.| The thermostat is exposed to air draft.
Eliminate the draft.
The sticker on the thermostat’s screen has not been removed.
Display disappears and reappears after a few minutes.| The thermal protection
device on the heater is open. This can happen after a power fail-ure or or if
the heater is obstructed by fumiture or curtains.
Display looks faded when heating is activated.| The heating system is less
than the required minimum load. This thermostat cannot be used below that
rating.
Electronic Thermostat
NOTE: All cables and connections must conform to the local electrical code. Special CO/ALR solderless connectors must be used when connecting with aluminium conductors.
Align and affix the base to the electrical box.
Set the switch at the back of the removable part of the thermostat to °C or °F.
Replace the front part of the thermostat on the base and secure it in place
with the screw.
Keep air vents of thermostat clean and free from obstructions.
√
Warranty
Honeywell warrants this product, excluding battery, to be free from defects in
the workmanship or materials, under normal use and service, for a period of
one (1) year from the date of purchase by the consumer. If at any time during
the warranty period the product is determined to be defective or malfunctions,
Honeywell shall repair or replace it (at Honeywell’s option). If the product
is defective, (i) return it, with a bill of sale or other dated proof of
purchase, to the place from which you purchased it, or (ii) call Honeywell
Customer Care at 1-800-468-1502.
Customer Care will make the determination whether the product should be
returned to the following address: Honeywell Return Goods, Dock 4 MN10-3860,
1885 Douglas Dr N, Golden Valley, MN 55422, or whether a replacement product
can be sent to you. This warranty does not cover removal or reinstallation
costs. This warranty shall not apply if it is shown by Honeywell that the
defect or malfunction was caused by damage that occurred while the product was
in the possession of a consumer. Honeywell’s sole responsibility shall be to
repair or replace the product within the terms stated above.
HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING
ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY,
FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF
THIS PRODUCT. Some states do not allow the exclusion or limitation of
incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT.
THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE
ONE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on
how long an implied warranty lasts, so the above limitation may not apply to
you.
This warranty gives you specific legal rights, and you may have other rights
which vary from state to state. If you have any questions concerning this
warranty, please write Honeywell Customer Relations, 1985 Douglas Dr, Golden
Valley, MN 55422 or call
1-800-468-1502. In Canada, write Retail
Products ON15-02H, Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive,
Scarborough, Ontario M1V4Z9.
Customer assistance
If you have any questions about the operation of your thermostat, please go to
http://yourhome.honeywell.com, or call Honeywell Customer Care toll-free at
1-800-468-1502. 69-1869ES
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>