CANVAC CLF1301V Ultrasonic Humidifier Instruction Manual

June 5, 2024
CANVAC

CANVAC CLF1301V Ultrasonic Humidifier

CANVAC CLF1301V Ultrasonic Humidifier

TECHNICAL INFORMATION

CANVAC QAIR HUMIDIFIER

Model| CLF1301V
Coverage| 45 m2
Width x Depth x Height| 210 x 123 x 300 mm
Max. humidifying capacity| > 300 ml/h
Water tank capacity| 4 litres
Rated voltage| 220–240 VAC
Mains frequency| 50/60 Hz
Rated power output| 25 W
Protection against electric shock:| Class II

SAFETY INSTRUCTIONS

Read the following safety instructions.

  • Make sure that the mains supply voltage matches the voltage rating of the product.
  •  Check that the plug fits your wall socket.
  • Never pull directly on the power cord; always pull out the plug to disconnect the unit from the mains electricity supply.
  • Do not use the product in a wet environment (such as a swimming area or bathroom), as this could lead to an electric shock or fire.
  • Remove the water tank before you move the unit.
  •  Do not place the unit in direct sunlight or near a heat source.
  •  If the power cord is damaged it must be replaced with an identical power cord from the dealer.
  •  Unplug the unit before you clean it, or if you do not intend to use it for some time.
  •  Do not touch the plug or power cord if your hands are wet (risk of electric shock).
  •  Do not place other items on top of the unit.
  • Do not let children get close to the unit.
  • Return the unit to our service centre for repair if it is damaged or does not work correctly.

MAIN COMPONENTS

CANVAC CLF1301V Ultrasonic Humidifier 1

  1. Mist nozzle
  2.  Water tank
  3. Water filter
  4.  Tank lid
  5. Bowl and ultrasonic transducer
  6. Control knob
  7.  Aroma pad
  8. Plug

FEATURES

  • Adjustable mist setting (rotary knob)
  • Aroma diffuser (water-soluble aromatic oils can be bought separately from retail outlets)
  • Large tank lid for easy cleaning
  • Automatic shut-off with low water level indicator
  • Automatic shut-off when water tank is removed
  • Limescale filter for longer life
  • Integrated design ensures quiet operation

PLACEMENT

  1. Place the unit on a flat, steady surface. It is recommended that the unit is placed on a moisture-resistant surface.
  2. Position the humidifier well away from heat sources such as a stove or open fireplace. Do not place it in direct sunlight.
  3. Position the humidifier well away from moisture-sensitive furniture and electronic devices.

USER INSTRUCTIONS

OPERATING CONDITIONS

  1.  The humidifier starts working when the temperature is between 5 and 45 ˚C and the relative humidity is below 80%.
  2. Run the unit at low mist level when the relative humidity in the room is higher than 70% (or in a closed room).
  3.  Use clean water that is below 40 ˚C (if your tap water is hard we recommend that you use distilled water).
  4. Clean the water tank and water bowl before long periods of disuse or at least twice each week if the unit is in continuous use.
  5.  We recommend that you soak the unit’s water filter for 24 hours before using the filter for the first time.

OPERATION

  1. Remove the water tank from the unit. Unscrew the lid and fill the tank with clean water. Screw the lid back on (making sure that it fits securely). Refit the water tank in the unit (making sure that it fits securely).
  2. Make sure that the mist nozzle is correctly fitted to the water tank.
  3. Plug in the unit and turn the knob clockwise to start it. Turn the knob clockwise to increase the mist flow. Turn the knob anticlockwise to reduce the mist flow or to turn off the unit.
  4. When the water has run out the indicator light will turn red and the unit will switch itself off. If this happens, refill the tank and turn the unit on again.
  5.  If the tank is removed while the unit is in operation the unit will switch itself off. It will start again when the water tank is replaced.
  6. Follow the instructions below to use the aroma diffuser feature (water-soluble aromatic oils can be bought separately from retail outlets).
    • Remove the aroma pad.
    • Place a few drops of water-soluble aromatic oil on the pad.
    • Refit the aroma pad in the unit (the aroma diffuser will start automatically when you turn the unit on).
    •  When you have finished using the aroma diffuser feature (or if the unit will not be used for some time) remove the pad from the aroma diffuser and clean it. Refit the pad when you have cleaned it.

CLEANING AND MAINTENANCE

  • Switch off the unit and unplug the power cord before you start cleaning.

BOWL AND ULTRASONIC TRANSDUCER

  • In areas with very hard water the ultrasonic transducer may become coated with limescale (if so, clean the transducer inside the bowl using descaler, which is widely available from supermarkets).
  • Apply a small amount of the descaler to the surface of the ultrasonic transducer (amount depends on extent of deposits). Then place it in water for 10–15 minutes.
  • Clean with a soft brush or sponge to remove the deposits.
  • Rinse twice in clean water.
  • Do not clean the ultrasonic transducer with tools that could damage its surface (metal or other hard objects).

INSIDE OF WATER TANK

  • Clean the inside of the water tank and the mist nozzle at least twice each week if you use the unit frequently.
  • Wipe off any deposits from the inside of the water tank using a soft cloth.
  • More stubborn deposits can be rubbed off gently using a soft cleaning sponge.
  • Do not use detergents that contain acid, alkali or bleach to clean the water tank.

OUTSIDE OF WATER TANK

  • Clean with a cleaning sponge and dry with a soft cloth.
  •  If necessary the mist nozzle can be removed for cleaning.
  • Do not pour water directly into the mist nozzle after you have cleaned the inside.

LONG-TERM STORAGE

  • Pour all the water out of the tank, clean the tank and then dry the unit.
  • Make sure that all water has been removed from the unit before storing it.

PRODUCT DISPOSAL

According to law, electrical and electronic devices must be dis-posed of at recycling stations and certain parts must be recy-cled. Electrical and electronic devices marked with a recycling symbol must be taken to a municipal recycling station.

TROUBLESHOOTING

If the unit is not working correctly, check the following before reporting a fault. If the unit still does not work after you have checked the possible causes, there is some other problem. If so, contact the dealer/service centre to arrange repair.

PROBLEM POSSIBLE CAUSE SOLUTION
No mist Check the plug Plug into the wall socket
Check the power switch Turn on the power switch
No water in tank Fill with water
Not enough water in tank Fill with water
Mist has an odd smell Unit is new Remove the tank lid and place the water

tank in a cool, dry place for 12 hours
Dirty water / water in tank is old| Clean the water tank / pour out the old water and fill with fresh water
Unusual noise| Tank is incorrectly positioned| Place the tank in the correct position
Not enough water in tank| Fill with water
Unit is on an uneven surface| Place the unit on a flat, steady surface
Mist leaking out from area around nozzle| Poor seal between mist nozzle and water tank| Dip the cover from the mist nozzle in water and refit it