SPARK FABRICA SF-05 Spark Jet Pro Machine User Manual
- June 5, 2024
- Spark Fabrica
Table of Contents
SPARK FABRICA SF-05 Spark Jet Pro Machine User Manual
DISLCAIMER
Please read the manual carefully before installing and using this product. Failure to read or comply with this manual may result in injury to products and personnel, and Spark Fabrica shall not be responsible for this.
This product is a professional machine, we do not assume any responsibility for accidents or losses caused by the use or maintenance of this product by personnel without professional training and permission.
If the information contained in the manual or the product specifications are changed, Spark Fabrica will not inform you further and responsible for any errors or omissions.
Our company reserves the right to modify the user manual at any time.
PREFACE
*This manual includes warning, caution and notice concerning the safe operation of equipment. These warning-caution and notice come with the following icons. Please read them carefully!
WARNING This warning indicates a dangerous situation that may result in death or serious injury if not avoided.
CAUTION This alert indicates a dangerous situation that may result in mild or moderate injury if not avoided.
NOTICE This means that you need to be careful.
PRODUCT INTRODUCTION
This product belongs to special effects equipment, only for professional use.
This product belongs to the cold fireworks simulation special effects equipment, using CST technology, heating special metal powder, and sparking silver spark fountain which is safer than the traditional cold fireworks.lt has three controllable variables: height, density and duration.
This product is widely used in weddings, concerts, sports events, event meetings and so on.Stimulate your interest and light up your activity.
PRODUCT OVERVIEW
PRODUCT ACCESSORIES
1.6 Meter Power Plug
3 Meters Power Pair Cable
3 Meters DMX Pair Cable
Upload Box (Optional)
User Manual
Mounting Screw (Two pieces of each set)
NOTICE
Open the package carefully and check to make sure the goods are in good
condition.
SPARK FABRICA GRANULE
A special metal powder has the characteristics of high content, little residue, belonging to a special consumables with no smoke, odor and other harmful gas when sparking.
WARNING Only the consumables provided by Spark Fabrica shall not be liable for any damage to machines, personnel and property caused by the COs are allowed to be used. Spark Fabrica use of consumables not provided by the company.
TECHNICAL PARAMETER
Identification | Manufacturer | SPARK FABRICA |
---|---|---|
Nome | SPARK JET PRO | |
Model | SF-05 | |
AC Power | Input Voltage & Frequency | 100-1201/, 50 / 60HZ |
200-240V. 50 / 60HZ
Current Limiter Specifications| 6.3A100-120V / 6.3A.200-2401/
Constant Current| 5.5A.100-120V / 2.7A,200-240V
Nominal Total Power Consumption| 600W
Power Input Connector| SEETRONIC
Power Output Connector| SEETRONIC
DMX Signal Interface| SPIN
Heating| Heat Up Time| <5 Minutes
Hopper| Powder Tank Capacity| 150g
Removable Hoppe| N/A
Technical Parameters| Lineary Adjustable Density| 30-100%
Adjustable Height| 1.5-5m
Height Level| 1-10 Level
Powder Consumption (100% Output)| 20-25g/Minute
Maximum Single Continuous Duration| 30s
Control| Control Protocol| DMX-512
RFID Proximity Card| √
RDM| √
CAN| √
SMPTE| Touch Screen Console Support
Accessory| Power Plug| SEETRONIC (1.6Meter)
Remote Controller| Optional
DMX Cable| √ 3Meter
Power Cable| √ 3Meter
Safety Ring| ×
Safety Rope| ×
Bottom Mounting Screw| √
Software Upgrade Box| Optional
120ohms Terminal Resistance| Optional
Certification| CE| √
ROHS| √
Weight| Net Weight| 8kg
Gross Weight| 10kg
Dimensions| Machine Dimensions – LWH| 215mm213mm257mm
Pocking Dimensions – L’WH| 270mmt250mm330mm
Granule| Granule| Spark Fabrica Granule
SCREEN OPERATION GUIDE
BACK PANEL INTRODUCTION
MENU SETTING
NOTICE Press
NOTICE Press key or key to modify parameters. The parameters will be flash after the modification, and please press < OK > key to save the change.
NOTICE Press key will return to previous page.
STATUS ICONS
NOTICE When the icons are green means the machine is working normally, and yellow means abnormal.
Blower Motor | Temp Sensor Unconnected |
---|---|
Shaft Motor | Temp Over Heat |
Hopper Motor | Tip Over |
Lack Of Time | Sub PCB Connected |
PCB Too Hot | 2/3 Channel Mode Optional |
RDM
RDM allows the console with RDM function to set the DMX address and starting temperature of Spark Jet Pro.
DMX PARAMETER LIST
First Channel | Function |
---|---|
0-10 | Stop |
11-255 | Fountain Height 1-25 |
Second Channel | Function |
0-200 | Pre-heat Off |
11-39 | Emergency Stop |
56-200 | Clear Material |
240-255 | Pre-heat On |
Third Channel | Function |
0-255 | Density Adjustment (0 is Maximum Density) |
Softy Channel | Function |
0-200 | Control Off |
201-255 | Control On |
OPERATION NOTES
PLEASE READ THE FOLLOWING OPERATION NOTES CAREFULLY WORKING WOTH THE MACHUINE
WORKING CONDITION REQUIRED
WARNING
Do not mount the product on a flammable surface (linoleum, carpet, wood,
paper, carton, plastic, etc). Make sure there are no inflammable or
combustible materials in the using environment.
WARNING
Ground wafer entering or covering the bottom of the machine will cause machine
failure or electrical leakage risk. Make sure the bottom of the machine is at
a safe distance from the surface water in rainy weather to avoid surface the
machine from the bottom.
WARNING
Do not use in a confined space. Always install the product in a location with
adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
WARNING
This product has no lightning arrester, please do not use this product in
thunderstorm weather.
WARNING
Keep people or flammable materials at least 10 feet (3 meters) away from the
machine, and make sure that debris does not fall on flammable objects.
WARNING
Do not use the machine at temperature above 122 ‘F (50 c ).
SAFETY TIPS
WARNING
Always connect the ground wire to avoid electric shockJhe machine cannot be
submerged in water while operating it.
WARNING
Do Not touch the sparks.During heating up and operation, do not touch the
housing.
WARNING
Ensure nothing drop(s) into the nozzle of Spark Jet Pro unit Do Not cover
output nozzle port.
WARNING
The product is very hot during operation and it remains hot for a long time
after operation has stopped. Do not touch or put finger in the output nozzle.
WARNING
Make sure that children, unauthorized people and animals do not obtain access
to the machine.
WARNING
The noise level generated from the spark machine unit is estimated at 80dB
depending on the point nearest to the machine(s) during operational discharge
mode.
WARNING
Wear eye protection to avoid eye injury while filling granules and testing
spark machine(s).
WARNING
The proper firefighting extinguishers are recommended as follows:Any type of
sand or substance that can suffocate the active metals.Class “D” Fire
Extinguishers for Metal Substance Fires.
MACHINE OPERATION
PERPARATION
Install the machine on a firm and level ground, and the maximum tilt angle
shall not exceed 15 degrees.
INSTALL MACHINE
Install the product on truss by using the attached accessories.
**WARNING**
Keep people or flammable materials at least 10 feet (3 meters) away from the
machine, and make sure that debris does not fall on flammable objects.
*Specific installation notes please refer to “4 OPERATION NOTES”.
FILL IN SPARK FABRICA GRANULE
Spark Fabrica Granule is the consumable specially designed for spark machine, to simulate cold fountain fire-works effect for stage.
- Tear the vacuum package of granule, and fill in the Spark Fabrica Granule through the granule filling port on th top of the machine.
- Fill the consumable into the feed port, NOT into the output nozzle.
- Close the lid securely after filling.
- The capacity of storage bin is 150g.
WARNING
Make sure to fill the Spark Fabrica Granule through the feed port on the top
of the fixture when power supply is off.
WARNING
Wear eye protection to avoid eye injury while filling granules and testing
spark machine(s).
CONNECT THE MACHINE
- Connect power and DMX signal line.
- Connect the first machine’s power plug.
- Connect the other machines in series with the power cable.
- Connect the other machines in series with DMX connection line.
- Connect PYRO SIM CONTROLLER or DMX512 controller.
WARNING Do not use damaged power plug and power cable.One power plug is recommended to connect 4 units in series at most for this product.
CAUTION Please attach the configured 120 ohm terminal resistor to the outlet of the last machine to enhance the anti-interference of the machine.
CAUTION Please calculate all products’ total current required according to the power supply and fuse parameters of the products.
NOTICE The standard length of the power connection line and the signal connection line is 3 meters, and a longer length can be reached by connecting in series.
INITIAL SETTING
Setting | Range | Default |
---|---|---|
Set Temperature | 400-620 | 560 |
DMX Address | 1-512 | 1 |
DMX Channel Mode | 3/2 | 3 |
Density | 30-100 | 100 |
Safety Addresss | 0-512 | OFF(0) |
Tilt Sensor | ON/OFF | ON |
Restore Defaults | YES/NO | NO |
TFT BackLight | ON/OFF | ON |
Auto Heating | ON/OFF | ON |
- Turn on power
- Check the machine status icon(refer to icon introductions of 3.3)
CAUTION
When the icon shows yellow, it indicates that the machine is abnormal. Please
use it after asking the professional to check and repair the machine.
The sparking temperature of the machine is the factory default temperature. The product will heat up automatically when disconnected with DMX signal.Automatic heating function can be set to on or off, and the concrete operation please refer to “3.2 MENU SETTING”.
When spark machines connect DMX signal, the heating function can be started only on the Sim Pyro Console.
SET CHANNEL MODE
This machine has 2 channel mode and 3 channel mode, the specific setting please refer to “3.2 MENU SETTING”.
SET DMX ADDRESS
Please set DMX address according to channel mode:
- In the 2 channel mode, please set spark machines’ DMX address to 1.3.5.7
- In the 3 channel mode, please set spark machines’ DMX address to 1.4.7.10
NOTICE Please do not set address code repeatedly.
START TO SPARK
The machine can be controlled by Pyro Sim Controller console or DMX512 console.
TURN ON THE CONSOLE’ POWER
TURN ON HEATING FUNCTION
NOTICE
The heating function of the second channel DMX value is 240-255, and it takes
about 5 minutes to preheat after turning on.
NOTICE
When heating is turned on, the
NOTICE
Heating will complete after the
NOTICE
When using the Pyro Sim Controller controller,the screen will display the
real-time temperature of each machine. When the temperature value of the
control board turns green, it means that the heating is completed and the
machine enters the status of sparking.
ADJUST SPARKING HEIGHT
Adjust sparking height through the first channel, and the height adjustment values is DMX parameter values 11-255.
WARNING
Do Not touch the sparks or put finger in the output nozzle.
WARNING
During heating up and operation, do not touch the housing.
WARNING
Keep a minimum distance of 10 ff (3 m) from the machine to the nearest human
or flamma-ble material. And make sure no falling residue fly to flammable
material.
WARNING
The maximum height of indoor and outdoor granule is different. The maximum
height of indoor granule is 3.5 meters, while outdoor granule is 5 meters.
NOTICE
If spark machines are affected by wind, sparking height will be reduced,
sparking direction will also be affected by the wind and inclined.
NOTICE
The proper firefighting extinguishers are recommended as follows:Any type of
sand or substance that can suffocate the active metals.Class “D” Fire
Extinguishers for Metal Substance Fires,
ADJUST SPARKING DENSITY
This product has independent sparking density adjustment function. Machine’s sparking density can be controlled during sparking, which can offer you more special effects choices for show.
NOTICE
The third channel is density adjustment channel, and the density is 30-100%.
The default sparking density is 100%, and the density adjustment parameter
values are 0-255. 0 means 100% density, and bigger DMX number means lower
density.
SPARK THROUGH REMOTE CONTROLLER
- Turn on the power,and leave DMX signal disconnected,
- Hold”A”for 2 seconds in the first interface until the screen shows”Control Pair Remoter 315M”.
- Press on remote controller until the screen shows”Code Success”,it means the coding is successful.
- One remote controller is recommended to control 4 units at most.
CAUTION
The remote controller can be used after coding when DMX signal is
disconnected,or the function will be broken.
CAUTION
Sparking stops automatically after 30 seconds,and clearing material stops
after 5 seconds.
CAUTION
The remote controller has 4 height levels.
CLEAR MATERIAL
This product has the function of cleaning material, which can clean up the heated but not sparked consumables, so as to avoid nodulation in the heating chamber and causing stuck machine.
NOTICE
Use the cleaning function of the second channel for cleaning, DMX value is
56-200.
NOTICE
This function must be performed at the end of each show.
CLEAN MACHINE
After clearing meterial, please clean the machine to extend the service life of the machine.
- Turn off the machine’s power.
- Remove power connection and DMX signal cable.
- Use a damp cloth to remove dust and debris from the surface of the machine.
- Unused Spark Fabrica Granule should be stored in a cool, dry place, vacuum packed insealed foil bags, and prote-cted from moisture, heat, hot surface, open fire and other ignition sources.
WARNING
The product is very hot during operation and it remains hot for a long time
after operation has stopped.
CAUTION
To eliminate unnecessary machine wear and improve its lifespan,unplug the
power of the machine during the period of not-in-use.Never power off the
product by pulling or tugging on the power cord.
MACHINE MAINTENANCE
Some steps are needed in order to clean and maintain the product for maximum usage. The recommended procedure is as follows:
CAUTION
After a period of using, check if there is any consumable accretion inside the
nozzle. Do necessary cleaning up if there has some, or it may affect spark
performance, even damage the machine.
FAILURE HANDLING
Error Code | Description | Solution |
---|
System Error
EC Storage Fail
| System Error: Storage Foil| Replace moan board
Motor Protect El M1| Blower motor protection/ disconnected|
- Restart machine to clear alerts.stop operating for 15 minutes until temperature return to normal.
- Check wire connection of motor
- Replace motor
- Replace main board
Motor Protect El M2| Shaft motor protection/ disconnected|
- Shaff motor dog (perform dean material function manually)
- Check wire connection of motor
- Replace motor
- Reploce main board
Motor Protect El M3| Hopper motor protection/ disconnectd|
- Hopper motor dog ( perform dean material function monuolll:
- Check wire connection of motor
- Replace motor
- Replace main board
Temp Sensor E2 Unconnected| Temperature sensor disconnected|
- Check wire connection of temperature sensor
- Replace Temperatlon sensor
- Repalce Main board
PCB Too Hot E3| Main board too hot| Stop operating machine until main board
temperature return to normal
lime Remain Ed| Insufficient time| Please scan new RFID card
Temp Over Heat E5| Heating protection due to over temperature.| Stop operating
machine until temperature return to normal. Ned wil clear off automatically.
Heat Fail E6| Heating process fall|
- Inspect Wire connection of heating board.
- Replace heating col
- Replace heating board
Tip Over E7| Tip over alert| Machine wil activate tip over protection if the
angle Is more than 45 degrees.The alert wil clear off automatically alter put
the machine bock to normal position.
Sub PCB Unconnected E8| Sub-PCB disconnected|
- Check wire connection of Sub-PCB
- Replace Sub-PCB
- Replace Main Board
Mega) Cord Machine Locked| Machine locked because of using Regal or copy RFID card.| Use Regal or copy RRD cord wil lock the machine. If so miler wil stop providing warranty and after sole service. To unlock the machine.please contact seler.
marketing@sparkfabrica.com | +86 138 7585 1139
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>