Ferry Smart ISE101T-5 Living Presence Sensor User Manual

June 13, 2024
Ferry Smart

Ferry Smart ISE101T-5 Living Presence Sensor

Product Information

Product Name| Living presence sensor (switch function)- Graffiti wifi
version
---|---
Product Model| ISE101T-5
Date| 2022-6-19
Product Characteristics| In vivo detection algorithm, movement, micromovement, breathing
mixed detection, to achieve true presence sensing; Remote control
design, users can configure the induction parameters according to
the needs; Support embedded independent; 3-year warranty (free
replacement within 1 year for nonhuman damage).
Specification Parameters|

  • Operating voltage: Input frequency
  • Standby power consumption
  • Lightning strike surge exportation
  • Working mode
  • Load type
  • Load power
  • Induction parameter
  • Load surge current
  • Operating frequency
  • Transmitting power
  • Delay setting (Hold time)
  • Detection range
  • Light and dark settings (Daylight)
  • Detection range (radius)
  • Environment
  • Certification standard
  • Recommended installation height
  • Detection Angle
  • Ambient temperature/humidity
  • Store temperature/humidity
  • Safety Regulation (LVD) standard
  • Electromagnetic Compatibility(EMC) standards
  • Environmental protection requirement
  • Compliance certification

Other| Input/output (terminal/lead): Shrapnel lifting terminal block
0.75mm2-1.5mm2
Class of protection: Embedded exposed parts; Overall protection
level: IP20
Product category: Second class electrical apparatus
Installation requirements: Built-in independent installation
Opening size
Packing requirement: White box + Flat card + Outer box (K=A)
Net weight: 150g
Life span: 3 year Warranty @Ta 230V full load
Features| Signal detection description: Detect people walking, body
movement, head up, turn and other small movements in normal work
and life, as well as breathing signals, and realize the detection
of human existence in sleep state.
Large mobile signal trigger
Small motion signal maintenance
Sedentary breathing signal maintained
Sleep state signal maintenance
*Mobile signal: large movement of the body, used for induction
triggering

  • Micromotion signal: sensor real-time detection, indicator light
    on
  • Respiratory signal: In the absence of micromotion signal, the
    sensor continuously detects the respiratory signal, and the
    indicator light is on
    When there is plenty of natural light, the lights remain off even
    if there is a human Sleep state signal maintenance body
    moving.
    When the natural light is insufficient, the human body movement
    signal is detected, and the light is automatically turned on.
    By detecting normal body movements in human life, the light stays
    on.
    The light stays on while the person is asleep
    When people leave, waiting time, the lights automatically turn
    off.

Product Usage Instructions

  1. Install the living presence sensor in a suitable locationbased on the recommended installation height and detection angle.
  2. Connect the sensor to the power supply according to the specified operating voltage and frequency.
  3. Configure the induction parameters using the remote control.This allows you to customize the sensor’s sensitivity to differentmovements.
  4. Depending on the ambient lighting conditions, adjust the light and dark settings (Daylight) to ensure optimal functionality.
  5. The sensor will detect people walking, body movement, head up, turn, and other small movements in normal work and life. It can also detect breathing signals to determine human presence even during sleep state.
  6. When there is sufficient natural light, the lights will remain off even if there is a human presence detected.
  7. If the natural light is insufficient, the sensor will detecthuman body movement signals and automatically turn on the lights.
  8. The lights will stay on while the person is awake and moving within the detection range.
  9. During sleep, the lights will stay on to maintain the sleep state signal.
  10. When people leave the area, the lights will automatically turn off after a specified waiting time.
  11. The living presence sensor comes with a 3-year warranty,with free replacement within the first year for non-human damage.

Product application description

Product name: Living presence sensor (switch function)- Graffiti wifi version

Product model: ISE101T-5

Date: 2022-6-19

All technical information is subject to actual performance, product model, parameters are subject to change without prior notice, the company reserves the right to final interpretation Page 1 consists of 7 pages

Product Characteristics

  1. In vivo detection algorithm, movement, micromovement, breathing mixed detection, to achieve true presence sensing;
  2. Remote control design, users can configure the inductionparameters according to the needs ;
  3. Support embedded independent ;
  4. 3-year warranty (free replacement within 1 year for nonhuman damage).

Specification parameter


Input



exportation

| Operating voltage| 110V-265V AC
---|---|---
frequency| 50/60Hz
Standby power consumption| < 1.0 W.
Lightning strike surge| L N 4KV between the two phases
Working mode| ON/OFF
 | Load type| Resistive, capacitive, LED load
 | Load power| Resistive load: 800W Capacitive load: 400w, LED load:400w
 | Load surge current| 110V-10A 220V-5A relay
Induction parameter| Operating frequency| 5.8GHz , AIoT mmWave.
Transmitting power| 0.5mW Max.
Delay setting (Hold time)| 5S-30Min
Detection range| 100% / 75% / 50% / 25%
Light and dark Settings (Daylight)| 5lux-150lux /Disable
Detection range (radius)| Moving sensing distance: 1-10m;Fretting detection distance: 1-5m;Breath detection distance: 1-3m
Recommended installation height| 2.5-4m, 3m recommended
Detection Angle| 90°
environment| Ambient temperature/humidity| 25 ℃… + 50 ℃
Store temperature/humidity| – 40 ℃… + 80 ℃
Certification standard| Safety Regulation (LVD) standard| EN61058-1,EN61058-1-2
Electromagnetic Compatibility(EMC) standards| EN300440; EN301489-1;EN55015;EN61547;EN62479
Environmental protection requirement| Meet RoHS requirements
Compliance certification| CE RED

All technical information is subject to actual performance, product model, parameters are subject to change without prior notice, the company reserves the right to final interpretation Page 2 consists of 7 pages

other| Input/output (terminal/lead)| Shrapnel lifting terminal block 0.75mm2-1.5mm2
---|---|---
Class of protection| Embedded exposed parts; Overall protection level:IP20
Product category| Second class electrical apparatus
Installation requirements| Built-in independent installation
Opening size| Ø 65 – Ø 75
Packing requirement| White box + Flat card + Outer box (K=A)
Net weight| 150g
Life span| 3 year Warranty @Ta 230V full load
Note: 1. If no specification parameter is set to N/A, 2. Describe test conditions

Feature

Signal detection description: Detect people walking, body movement, head up, turn and other small movements in normal work and life, as well as breathing signals, and realize the detection of human existence in sleep state.

  • Large mobile signal trigger
  • Small motion signal maintenance
  • Sedentary breathing signal maintained
  • Sleep state signal maintenance
  • Mobile signal: large movement of the body, used for induction triggering
  • Micromotion signal: sensor real-time detection, indicator light on
  • Respiratory signal: In the absence of micromotion signal, the sensor continuously detects the respiratory signal, and the indicator light is on

When there is plenty  of natural light, the lights remain off even if there is a human Sleep state signal maintenance body moving.

  • When the natural  light is insufficient, the human body movement signal is detected, and the light is automatically turned on.
  • By detecting normalbody movements in human life, the light stays on.
  • The light stays onwhile the person is asleep
  • When people leave, waiting time, thelights automatically turn off.

All technical information is subject to actual performance, product model, parameters are subject to change without prior notice, the company reserves the right to final interpretation Page 3 consists of 7 pages

Dimension

Dimensional drawing (unit: mm)

Wiring diagram

Note: When this product is connected with multiple loads, it is necessary to refer to the surge value, total load and the induction range to be covered

Functional diagram

All technical information is subject to actual performance, product model, parameters are subject to change without prior notice, the company reserves the right to final interpretation Page 4 consists of 7 pages

Installation Diagram

  1. Smallpox openingφ65-70mm
  2. Carefully pry open the button of the swivel cover and open it to maximum
  3. Wiring (note that input and outputcannot be reversed)
  4. Install the cable tie locking screw and cover the rotating protective cover
  5. Bend the spring clamp backwards to push the pre-opened hole in the ceiling
  6. Ensure smooth and reliable installation.

Detection Range

Note: The dark color is the high sensitivity respiratory heartbeat detection area, and the light color is the low sensitivity large motion detection area

Tuya APP settings

  1. Tuya APP download: Search for “Tuya Smart” in major application markets to download and install
  2. First use: power on the sensor, open the Tuya APP (need to open the mobile phone Bluetooth) to add the device, and connect to the same WiFi router as the mobile phone by default
  3. Replace the WiFi router: long press the signal indication button, the indicator light flashes three times to enter the reconfiguration state, at this time you can add the device configuration network through the Tuya APP again

Note: The sensor returns to the last set parameter after the power restart

Initialize

When the sensor is powered on for the first time, it enters the self-test mode, completes the self-test for 1 second and enters the normal working state. During the initialization, it does not detect the external mobile induction signal, nor receives the remote control signal

Factory Setting

  • Sensing distance: 25%
  • Sensing sensitivity: 100%
  • Delay: 30M
  • Light threshold: Disable
  • Indicator control: Open

Precautions for use

  1. The sensor should be installed by a professional electrician. Please power off before installation, wiring and changing the dip switch Settings
  2. The sensor should be far away from substances with large media density such as metal plate andglass to avoid causing false trigger.
  3. Avoid using objects that vibrate for a long time around the sensor, shaking fans, etc. The vibration signal will be regarded as a mobile signal to trigger the sensor.
  4. Non-human objects in continuous motion, such as animals, curtains that continue to swing, and large green plants facing the outlet should be avoided in the sensing area
  5. The product is set by remote control each time the setting is successful, the indicator light flashes three times quickly, indicating that the setting is successful.
  6. It is recommended to turn off the indicator during normal use.
  7. Applied to open office places with many people, the induction time can be selected 30s, and the independent office needs to use 1min and more than 3min.
  8. The microwave sensor has a certain penetration ability to the building wall, and the microwave penetrating outside the wall may cause false positives when it acts on moving objects outside the fortified area. In order to avoid false triggering, attention should be paid to selecting the installation position and the appropriate induction range during installation, such as:
    • When applied in A room with an area of about 5 square meters or smaller, the sensing distance should be set to 25% and the sensitivity should be 100%
    • When applied in a room with an area of about 10 square meters, the induction distance should be set to 50% and the sensitivity should be 100%
    • When applied in a room with an area of about 30 square meters, the induction distance should be set to 75% and the sensitivity should be 100%
    • When applied in a room with an area of about 100 square meters or larger, the sensing distance should be set to 100% and the sensitivity to 100%

FCC

FCC Warning:
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined by turning theequipment off and on, the user is encouraged to try to correct the interference by one or  more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals