INFICON CO Check Carbon Monoxide Meter Instruction Manual

June 5, 2024
INFICON

INFICON CO Check Carbon Monoxide Meter-logo

INFICON CO Check Carbon Monoxide Meter

INFICON CO Check Carbon Monoxide Meter-prod

The CO Check Carbon Monoxide Meter measures the presence of carbon monoxide (CO), indicating the gas’s concentration in atmosphere between the values of 1 – 999 parts per million.

CAUTION
Do not use the CO Check as a personal safety monitor. The CO Check should be recalibrated yearly.

OPERATING INSTRUCTIONS

  1. Remove the battery access door and install the 9-volt alkaline battery.
  2. Turn “ON” the detector by pressing the right-hand button. The meter will give you a short beep to indicate the power has been turned “ON”.
  3. The CO Check will take 30 seconds to run through a self-check and warm up. During this period, the display will indicate the time remaining before the meter is ready for operation.
  4. The CO Check should be turned “ON” in an area known to be free of carbon monoxide contamination. The meter will automatically establish a zero point during start-up. However, if the ambient concentration of carbon monoxide is higher than 3 ppm during the zero process, the meter will not reset the zero point and will indicate the carbon monoxide concentration level.

DISPLAY FEATURES

  • Digital readout of parts per million concentrations in 1 ppm increments.
  • Low battery indicator (appears with approximately 1 hour lifetime remaining).
  • “MAX” indicator when meter is in maximum display mode.
  • Concentration indicators per the following chart:
    • 2 – 9 ppm. . . . . . . . . . . . . . . Yellow
    • 10 – 34 ppm . . . . . . . . . . . . Orange
    • 35 ppm or higher . . . . . . . . Red

AUDIBLE OUTPUTS

  • Short beep when CO Check is turned “ON”.
  • Two short beeps when the meter is warmed up and ready to take readings.
  • Geiger counter-like tick when the concentration of CO is between 35 – 200 ppm (frequency increases with increasing concentration of CO).
  • Constant alarm when concentration moves above 200 ppm.
  • Two short beeps when the meter shuts down after 20 minutes of operation.
  • Two short beeps when shut down because of a low battery.

MAXIMUM READING MODE
When in the maximum reading mode, the CO Check will display the maximum reading it measures. Press the left hand “MAX” button and the meter will display the maximum carbon monoxide concentration measured after the meter was put into maximum mode. “MAX” will appear on CO Check’s display when in maximum mode. All display and audible features are still active when in maximum mode.

AUTOMATIC POWER OFF
The CO Check automatically turns off after 20 minutes. When starting up after an automatic shut down, the concentration reading the meter was displaying when shut down will flash for 5 seconds before the meter returns to reading the concentration in real time.

SPECIFICATIONS

  • Usage . . . . . . . . . . . . . . . . . Indoor or Outdoor,
  • Humidity. . . . . . . . . . . . . . . 90% RH NC Max.,
  • Battery: . . . . . . . . . . . . . . . . One 9 volt alkaline, Altitude. . . . . . . . . . . . . . . . .2000 m
  • Battery Life. . . . . . . . . . . . . 200 hours,
  • Operating temperature . . . . 32 – 110 °F,
  • Concentration range . . . . . . 0 to 999 ppm CO,
  • Pollution degree . . . . . . . . . .2
  • Overvoltage category . . . . . .2
  • Weight . . . . . . . . . . . . . . . . .9.0 oz (250 g)
  • Storage temperature . . . . . . .14 – 122 °F
  • Accuracy. . . . . . . . . . . . . . . .1 ppm ±3% of

DECLARATION OF CONFORMITY
This is to certify that this equipment, designed and manufactured by INFICON Inc., Two Technology Place, East Syracuse, NY 13057 USA meets the essential safety requirements of the European Union and is placed on the market accordingly. It has been constructed in accordance with good engineering practice in safety matters in force in the Community and does not endanger the safety of persons, domestic animals or property when properly installed and maintained and used in applications for which it was made.

  • Equipment Description . . . . . . . . . CO Check Carbon Monoxide Meter
  • Applicable Directives . . . . . . . . . . 73/23/EEC as amended by 93/68/EEC 89/336/EEC as amended by 93/68 EEC
  • Applicable Standards . . . . . . . . . . EN 61010-1: 1993 EN 61326: 2000-11, EMC Cl A, Immunity Criteria B
  • CE Implementation Date . . . . . . . January, 2005
  • Authorized Representative . . . . . . Gary W. Lewis, Vice President of Quality Assurance, INFICON Inc. Any questions relative to this declaration or to the safety of INFICON products should be directed, in writing, to the quality assurance department at the above address

WARRANTY

INFICON warrants your CO Check to be free from defects of materials or workmanship for two (2) years from date of purchase. INFICON does not warrant items that deteriorate under normal use, including batteries. INFICON does not warrant any instrument that has been subjected to misuse, negligence or accident or has been repaired or altered by anyone other than INFICON. This warranty is a replacement warranty for two years. INFICON will not repair a unit within the warranty period. Out of warranty repair can be arranged by returning the unit to your local distributor.