VT 1831
DESCRIPTION OF THIS PRODUCT
DIGITAL VETERINARY THERMOMETER
Read the instructions carefully before using this device.
IMPORTANT SAFETY INSTRUCTIONS
- Follow instructions for use. This document provides important product operation and safety information regarding this device. Please read this document thoroughly before using the device and keep it for future reference.
- The thermometer is exclusively for the measurement of the animal body temperature.
- The minimum measurement time until the signaling tone [beep] must be maintained without exception!
- Ensure that children do not use this device unsupervised; some parts are small enough to be swallowed.
- Do not use this device close to strong electromagnetic fields such as mobile telephones or radio installations. Keep a minimum distance of 3.3 m from such devices when using this device.
- Protect the thermometer from hitting and striking!
- Avoid ambient temperatures above 60 °C. NEVER boil the thermometer!
- Use only the commercial disinfectants listed in the section «cleaning and disinfecting» to clean the thermometer. The thermometer must be intact when immersed in liquid disinfectant.
- The manufacturer recommends verifying the accuracy by an authorized laboratory every 2 years.
WARNING: The measurement result given by this device is not a diagnosis!
Do not rely on the measurement result only.
Batteries and electronic instruments must be disposed of in accordance with
the locally applicable regulations, not with domestic waste.
TURNING ON THE THERMOMETER
To turn on the thermometer, push the ON/OFF button; a short signaling tone [beep] signals «thermometer ON». A display test is performed. All segments should be displayed. Then at an ambient temperature of less than 32 °C, «- – -» and a flashing «°C» appear at the upper right of the display. The thermometer is now ready for use.
FUNCTION TEST
The proper functioning of the thermometer is tested automatically each time it is turned on. If a malfunction is detected (measu rement inaccuracy), this is indicated by «ERR» on the display, and measurement becomes impossible. In this case, the thermometer must be replaced.
USING THE THERMOMETER
During a measurement, the current temperature is displayed continuously. The
«°C» symbol flashes during this period of time. If the signal tone sounds
(beep-beep-beep-beep 10 times) and the «°C» is no longer flashing, this
means that the measured increase in temperature is now less than 0.1 °C in 8
seconds and that the thermometer is ready for reading.
To prolong the life of the battery, turn the thermometer off after use by
pressing the operating button briefly. Otherwise, the thermometer will
automatically turn off after about 10 minutes.
STORAGE OF MEASURED VALUES
If you hold the button down for more than 3 seconds when turning the thermometer on, the maximum temperature stored automatically at the last measurement will be displayed. At the same time, a small «M» for memory will appear at the right of the display. After 3 more seconds, this value will disappear and the thermometer will automatically turn off.
CLEANING AND DISINFECTING
The thermometer is 100 % waterproof and may be immersed in water or
disinfectant solution for cleaning with no problem. Then wipe it off with a
moist towel. Please use the following disinfectant for disinfecting, following
the manufacturer’s instructions:
Note: Any other cleaning solution, dilution, or cleaning method can cause
a malfunction of the thermometer! The thermometer must never be boiled!
Name of disinfectant
MEASURING METHODS
In the anus (rectal)
Carefully insert the tip of the thermometer 2 to 3 cm into the anal aperture.
Approx. measuring time: 10 seconds!
BATTERY REPLACEMENT
When the «▼» symbol (upside-down triangle) appears in the lower right of the
display, the battery is exhausted and needs replacing. For the battery
replacement please remove the compartment lid of the thermometer. Replace the
exhausted battery by positioning the + at the top. Make sure a battery of the
same type is on hand. Batteries can be purchased at any electrical goods shop.
For battery disposal please refer to «safety instructions».
GUARANTEE
This device is covered by a lifetime guarantee from the date of purchase.
During this guarantee period, at our discretion, Microlife will repair or
replace the defective product free of charge. Opening or altering the device
invalidates the guarantee.
The following items are excluded from the guarantee:
- Transport costs and risks of transport.
- Damage caused by the incorrect application or non-compliance with the instructions for use.
- Damage caused by leaking batteries.
- Damage caused by accident or misuse.
- Packaging/storage material and instructions for use
- Regular checks and maintenance (calibration).
- Accessories and wearing parts: Battery.
Should guarantee service be required, please contact the dealer from where the product was purchased or your local Microlife service. You may contact your local Microlife service through our website: www.microlife.com/support
Compensation is limited to the value of the product. The guarantee will be granted if the complete product is returned with the original invoice. Repair or replacement within the guarantee does not prolong or renew the guarantee period. The legal claims and rights of consumers are not limited by this guarantee.
Date of purchase:
TECHNICAL SPECIFICATIONS
Type | Maximum thermometer |
---|---|
Measurement range | 32.0 °C to 42.9 °C |
Temp. < 32.0 °C: display «- – -» for low (too low)
Temp. > 42.9 °C: display «H» for high (too high)
Measurement accuracy| ± 0.1 °C between 34 °C and 42 °C
± 0.2 °C; 32.0 – 33.9 °C and 42.1 – 42.9 °C
Operating conditions| 10 °C to 40 °C;
15 – 95 % relative maximum humidity
Self-test| Automatic internal check at a test value of 37.0 °C if there is a
deviation of > 0.1 °C, «ERR» (error) is displayed.
Display| Liquid crystal display (LCD) with 3 digits. The smallest unit of
display: 0.1 °C
Signal tone| For signaling that the thermometer is ready to use and that the
temperature increase is less than 0.1 °C / 8seconds.
Memory| For storing the last measured value.
Storage conditions| -25 °C to +60 °C;
15 – 95 % relative maximum humidity
Battery| LR41 (1.5V) / SR41 (1.55V)
Battery lifetime| approx. 4500 measurements (using a new battery)
IP Class| IP67
Reference to standards| EN 12470-3; ASTM E1112;
IEC 60601-1; IEC 60601-1-2 (EMC);
IEC 60601-1-11
Expected service life| 5 years or 10000 measurements
This device complies with the requirements of the Medical Device Directive 93/42/EEC. Technical alterations reserved.
**** Microlife AG
Espenstrasse 139
9443 Widnau / Switzerland
Microlife UAB
P. Lukšio g. 32
08222 Vilnius / Lithuania
**** Type BF applied part