DESCRIPTION

  1. Body
  2. Display
  3. Switch of metages
  4. Control panel
  5. Еlectrodes
  6. 2 batteries 1.5V AAA ( included)
  7. Batteries compartment

IMPORTANT SAFEGUARDS

  • To avoid breakdown during use read this guide carefully before operating the appliance. Mishandling can cause breakdown of the appliance.
  • Only for domestic use. The appliance is not designed for industrial or commercial use.
  • Do not expose the scale to shocking.
  • Do not jump on the scale.
  • Do not overload the scale.
  • It is forbidden for use by persons with medical implants (for example, with pacemakers). Otherwise, faulty operation of implants might occur.
  • Do not use during pregnancy.
  • Attention! Do not step on the scale if your feet or the scale surface are wet – you might slip.
  • Batteries may be life-threatening if swallowed.
  • Store the batteries and the scale out of the reach of children. The person who swallowed a battery, should immediately consult a doctor.
  • Do not allow wrapping material getting into the hands of children (choking hazard).
  • It is forbidden to recharge or restore batteries in other manner, disassemble them, or throw into fire.
  • Measuring body fat percentage and other parameters in children below 10 years of age may yield invalid results.
  • Diagnostic scale may be used for simple weighing without determining water, body fat or muscle mass parameters in children of any age. Minimum weighing limit is 2 kg.
  • Unreliable results of measuring body water, body fat or muscle mass might occur in professional athletes, persons prone to oedema, persons with irregular leg-to-body ratio.
  • Never try to repair this appliance by yourself. In case of failure, contact the nearest seller.
  • If the product has been exposed to temperatures below 0ºC for some time it should be kept at room temperature for at least 2 hours before turning it on.
  • The manufacturer shall reserve the right to introduce minor changes into the design of the scale, which do not affect its safety, performance capacity or functionality of the appliance.
  • Manufacturing date is indicated on the unit and/or on packing as well as in accompanying documents in the following format XX.XXXX where first two figures XX is the month of production, and following four figures XXXX is the year of production.

WEIGHING

PRINCIPLE OF OPERATION
  • The principle behind this scale is bioelectrical impedance analysis (B.I.A.). The measurement of the percentage of different tissues occurs within seconds with electric current, which is not perceptible for a human, safe and harmless.
  • It is important that during measurement you take into account the following: measurement of the body fat percentage must be performed only barefoot; it is advisable that you slightly moisturize the soles of your feet. Absolutely dry soles might be the cause of an unsatisfactory result, as they possess extremely low electric conductivity.
  • If, when measuring the percentage of fat, muscle tissue, bone and water content, the obtained sum of all components has become greater than 100%, this is not a sign of scale defect. It can be explained from the physiological point of view. Operation of the diagnostic scale is based on the analysis of bio impedance, which determines the amount of fat and water in muscle and bone tissues themselves. Thus the variation of different parameters should be taken into account separately from each other, without summarizing the obtained results.
WEIGHING
  • Make sure the scale stands on a flat, even and firm level surface. Do not put the scale onto a carpet or soft surfaces.
  • To ensure correct weight measurement it is advisable that the scale stand in the same place. By moving the scale you risk putting it on an uneven surface, which might affect the correctness of your weight reading.
  • To ensure correct weight measurement you need to weigh at the same time, without clothes or footwear, and before eating.
  • To ensure precise weight measurement it is not recommended to weigh earlier than 2 hours after waking.
  • Step on the scale. Do not lean against anything, stand straight.
GETTING STARTED
  • Insert type AAA batteries observing polarity into a special compartment at the bottom of the scale. Close the compartment. The scale is ready to operate.
  • By default the scale is set to stones. There is a switch on the rear panel of the scale, for selecting “kilos” or “pounds” as units of measurement.
  • Step on the scale to switch it on.
AUTOMATIC SHUTDOWN
  • If nothing happens within 20 seconds after switching on the scale will shut down automatically.
  • After weighing the scale shuts down automatically in 6 seconds without load.
AUTOMATIC RESET FUNCTION
  • Your scale has an automatic reset function. After the data are displayed on the screen, the data will be reset in a few seconds and the screen will show 0.0 again. You may conduct the weighing again or start the weighing by setting a new user.
SETTING USER DATA
  • Input your parameters before the testing.
  • Press the “SET” button, and the screen will show the first out of twelve memory input cells.
  • Confirm the cell number by pressing “SET” button or select the next number by pressing buttons; for example, “2”. Press “SET” to go to the next settings.
  • Next the screen will show “male” or “female” symbol. Confirm the selection by pressing “SET” button or select your gender by pressing buttons.
  • Press “SET” to go to the next settings.
  • Similarly input the age parameters AGE (10-100 years) and the height parameters cm (100-250 cm).
  • Press “SET” button to confirm each parameter.
  • After the last parameter has been confirmed (height, cm), the screen will show “0.0” kg and the user number, for example, “2”. Your data have been saved.
  • Next time you turn on the scale, the screen will display the parameters of the last user.
WEIGHING WITH ANALYSIS
  • After selecting the user data start the weighing.
  • Stand still during the weighing so that the reading can get stable.
  • Attention: your feet, calves, ankles or thighs should not touch each other during the weighing. Otherwise the weighing results may be incorrect.
  • First the screen will display your weight, and then in a few seconds you will see the information on the percent share of the fat, water, muscle and bone mass in your body.
  • After the test you will see the calculation of your recommended daily caloric intake. Daily caloric intake is the number of calories which are needed for performing normal activities and for the support of your body without the accumulation of extra weight.
  • The analytical information will be displayed on the screen in the following sequence:
    Screen reading| Value
    ---|---
    | % fat content
    | % water content
    | % muscle mass
    | % bone mass
    | Recommended daily caloric intake
  • he data reflect your condition at the moment (see table)
    Age| Female| Male|
    ---|---|---|---
    Fat %| | Water %| Fat %| Water %| Fact content| Screen
    530| 4.0-16.0| 66.0-57.0| 4.0-11.0| 66.0-61.2| Very little| III
    16.1-20.5| 57.7-54.7| 11.1-15.5| 61.1-58.1| Little| III  III
    20.6-25.0| 54.6-57.6| 15.6-20.0| 58.0-55.0| Normal| 111111111
    25.1-30.5| 51.5-47.8| 20.1-24.5| 54.9-51.9| A lot| 111111111111
    30.6-60.0| 47.7-27.5| 24.6-60.0| 51.8-27.5| Quite a lot| III III III III Ill
    > 30| 4.0-20.0| 66.0-55.0| 4.0-15.0| 66.0-58.4| Very little| 1111
    20.1-25.0| 54.9-51.6| 15.1-19.5| 58.3-55.3| Little| 11111111
    25.1-30.0| 51.5-48.1| 19.6-24.0| 58.2-52.3| Normal| 1111111111
    30.1-35.5| 48.0-44.7| 24.1-28.5| 52.2-49.2| A lot| 111             111 111           111
    35.1-60.0| 44.6-27.5| 28.6-60.0| 49.1-27.5| Quite a lot| III III III III 1111

MESSAGES ON THE DISPLAY

  • ATTENTION: If an error message is displayed, wait until the appliance shuts down. Switch it on again to restart the operation. If the error message does not disappear remove batteries from the battery compartment for 10 seconds, after that insert them again and switch on the appliance.
Indicators Meaning
8888 Selection of the user and personal parameters
0000 Analysis of readings after weighing.
—-
  • Improper positioning of the scale. Place the scale on a flat, firm surface.
  • You are standing on the scale with your footwear on. Take off your footwear and step on the scale again.

LO| Indication of the low battery charge. The batteries are discharged, please, replace them with new ones.
ErrH| Indication of the high % of body fat. Body fat percentage is too high. Recommendations: you should keep to a low-calorie diet, do more exercise and pay more attention to your health.
Errl| Indication of the low % of body fat. Body fat percentage is too low. Recommendations: you should keep to a more nourishing diet and pay more attention to your health.
EEEE| Indication of overload. The weight exceeds maximum permissible value for measurement. Please, step off the platform to avoid damage to the scale.

CLEANING AND MAINTENANCE

  • Wipe the scale with a soft cloth using a detergent and wipe dry.
  • Do not use organic solvents, aggressive chemicals or abrasives.

STORAGE

  • Observe all requirements from the CLEANING AND MAINTENANCE Section.
  • Make sure there are no objects on the scale during storage.
  • Store the scale in a cool dry place.

BATTERIES USAGE RULES

  • Battery contains harmful substances for human body. Keep the wrapping materials out of reach of children (choking hazard). The person who swallowed a battery, should immediately consult a doctor.
  • Change the batteries regularly. Change all batteries at once using the elements of the same type.
  • It is forbidden to recharge or restore batteries in other manner, disassemble them, or throw into fire or hot-wire.
  • Discharged battery can be a reason of scale breakdown. Remove the batteries compartment in case of long out-of action time.
  • If one of the batteries is discharged, put protection gloves and clean the batteries compartment with dry cloth.
  • Batteries may contain toxic substances harmful for health and environment. The batteries should be disposed in strict compliance with existing law. Do not dispose the used batteries to the waste bin.
  • Do not throw the batteries into fire! Highly explosive!
  • The symbol on the unit, packing materials and/or documentations means used electrical and electronic units should not be toss in the garbage with ordinary household garbage. These units should be pass to special receiving point.
  • The symbol on the unit, packing materials and/or documentations means the battery used in this product not be toss in the garbage with ordinary household garbage.

For additional information about actual system of the garbage collection, address to the local authority.

Valid utilization will help to save valuable resources and avoid negative work on the public health and environment which happens with incorrect using garbage.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals