Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product’s serial number in the back of the manual (or month and year of purchase if product has no number). Keep this manual and the receipt in a safe and dry place for future reference. When unpacking, make sure that the product is intact and undamaged. If any parts are missing or broken, please call 1-888-866-5797 as soon as possible.
Specifications
Input
| Voltage| 12 VDC Nominal
(11-15 VDC)
---|---|---
Wire Gauge| Two 2/0 AWG (up to 3 ft.)
Internal Fuses| 35 A x 16
Input Fuse Rating| 560 A
Current| 476A (rated)
Output
| Continuous| 5000W
Surge| 10,000W
Receptacles| 4 AC outlets, 2 USB ports
Waveform| Modified Sine Wave
Voltage Range| 120 VAC
Frequency| 60 ± 2 Hz
Current| 43.48A
Maximum efficiency| >85%
---|---
Full load efficiency| >80%
Over voltage Shutdown| 15.75 ± 0.75 V
Low voltage alarm| 10.5 ± 0.5 V
Low voltage shutdown| 10 ± 0.5 V
Thermal Shutdown| 149 ± 9 °F
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Note: Battery charge level, wire length and other factors will effect performance.
- This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
- Indicates a hazardous situation which, if not avoided, will result in death or seAddresses practices not related to personal injury.rious injury.
- Addresses practices not related to personal injury.
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This manual contains important instructions that shall be followed during
installation and maintenance of the Inverter.
IMPROPER INSTALLATION OR USE CAN RESULT IN SERIOUS INJURY, PROPERTY DAMAGE, OR DEATH.
General Precautions
- The warnings, precautions, and instructions People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure.
- discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factor that cannot be built into this product but must be supplied by the operator.
Installation Precautions
-
DO NOT INSTALL THIS INVERTER INTO A BUILDING’S ELECTRICAL SYSTEM.
This Inverter is a vehicular accessory. is not designed to be safely used in a building’s electrical system and has not been evaluated to meet building wiring codes. Improper application may create a fire or electric shock hazard. -
To allow proper cooling, install in indoor well-ventilated area and do not cover ventilation openings or cooling fins. Do not install in engine compartment. Especially avoid placing the Inverter on carpets and rugs; they are not only flammable, but they also obstruct vents underneath it.
-
Keep combustible materials and gasses away from the Inverter. The Inverter produces sparks and heat during operation and can start a fire.
-
Connect to 12 VDC power supply only. A power supply with lower voltage will not operate the Inverter correctly, and higher voltage could damage the Inverter.
-
Connect input polarity properly. Incorrect connection will damage Inverter and void warranty.
-
Do not use in a marine application. This Inverter is not intended to withstand the highly corrosive conditions in marine applications and would quickly be rendered inoperable or unsafe.
-
Keep Inverter dry and clean. Do not expose to rain, snow, spray, bilge water or dust.
-
Use cables that are thick enough. The more power (amps) or the longer the cables, the thicker they need to be to prevent overheating and fire.
-
Install as close to DC source as possible, but not in a closed area with vented lead-acid batteries. Vented lead-acid batteries release explosive hydrogen gas that can be
-
Mount Inverter horizontally.
-
Verify that installation surface has no hidden utility lines before drilling or driving screws.
-
This product is not a toy. Keep it out of reach of children.
-
Do not use with positive ground electrical systems.(Most automobiles, trucks, and RV’s have negative ground systems.) The positive (+) battery on the Inverter must be the last connection made, and must be connected before the Inverter is turned on. There may be a small spark during thefinal connection. This is normal.
-
Properly ground the Inverter’s case as explained in this manual.
Battery Precautions
- Wear splash-resistant ANSI-approved safety goggles and electrically-insulated gloves while working near batteries.
- Charge, store, and maintain batteries according to supplier’s instructions.
- Locate batteries in a clean, well-ventilated area, away from ignition sources and flammable materials. Vented lead-acid batteries release explosive hydrogen gas while charging.
- Only connect similar batteries together.Do not connect old and new batteries together, flooded and gel cells together, or batteries of different capacities together.
- Use only 12 V batteries with this item.
- Connect batteries in parallel ONLY (negative terminals together to one cable; positive terminals together to the other cable).
- Install a properly rated fuse on the positive output of the battery bank.
Operation Precautions
- Multiple outlet power strips with switches and circuit breakers only interrupt power to the “hot” receptacle terminals. The “neutral” terminals remain powered with respect to the “ground” terminals. So strip switch may be off, but part of device may still be powered.
- Inspect supply connections before use to ensure they are tight and that insulation is not damaged.
- Do not use this Inverter to power sensitive devices such as medical devices or computers. Do not use in ignition protected areas.
- Some rechargeable devices can damage the Inverter. Check the temperature of the device several times when it is charging. If the device becomes extremely hot; turn the power off, remove the device, and do not use with the Inverter again.
- Check for breakage of parts and any other condition that may affect the Inverter’s operation. If damaged, have it repaired before use.
- If the Inverter is powered by a vehicle’s starting battery (not recommended), do not drive or move the vehicle if the Inverter is attached using alligator clips or another temporary means.
- Do not attempt to power a device, or combination of devices, that will require more than the rated output of this Inverter. This may damage the Inverter or the attached devices.
- Appliances such as microwave ovens will normally draw more than their rated current. For example: A typical 600 watt microwave oven will draw approximately 1,000 watts.
- Do not attach a battery charger if the charger carries a warning that dangerous voltages are present at the battery terminals.
- Some fluorescent lamps may not operate properly with this type of Inverter. If the bulb appears to be too bright, or fails to light, do not use the lamp with this Inverter.
- some fans with synchronous motors may slightly increase in speed when powered by the Inverter. This is not harmful to the fan or to the Inverter.
- The inverter will consume some power while on, even without loads attached. Turn Inverter off after use.
Service Precautions
- DO NOT OPEN HOUSING. Contains no user-serviceable parts. Internal parts may be electrified, even with Inverter off and power disconnected.
- Maintain labels and nameplates on the Inverter. These carry important safety information. If unreadable or missing, contact Harbor Freight Tools for a replacement.
- Have your Inverter serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the Inverter is maintained.
- Fuses must be replaced with fuses of the same type and rating only.
Output Waveform
- This Inverter’s output is a Modified Sine Wave.Power from most electric utilities is a Sine Wave. Note: Only multimeters identified as “TRUE RMS” will read Modified Sine Wave voltage accurately.Installation
- Modified Sine Wave (MSW) power is suitable for most AC devices and power supplies used in electronic equipment, transform ers, and motors. Do not use to power sensitive devices such as medical equipment or computers. Some audio equipment may perform poorly if run on Modified Sine Wave power.
- Sine Wave Inverters provide power that is identical to, or even better than, the power supplied by your power company. Motors start easier and run cooler under Sine Wave power. Certain devices, such as laser printers, variable speed motors and digital clocks, require sine wave power to operate properly. Sine wave Inverters are typically more expensive for their capacity than other Inverters.
Installation
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this document including all text under subheadings therein before set up or use of this product.This Inverter must only be connected to batteries with a output voltage of 12 volts DC.Lower voltage will not operate the Inverter properly, and more voltage could damage the Inverter or the device being powered. Do not use this Inverter with positive ground electrical systems.The Inverter has a number of shut-down points, for the safety of the operator, the Inverter, and the devices being used with it.
- If the DC input voltage drops too low, the alarm on the Inverter will sound. If the input voltage drops further, the Inverter will shut down automatically to prevent permanent battery damage. Recharge the battery soon.
- If the DC input voltage exceeds 15 V the Inverter will shut down automatically.
- If the output load power rises higher than the rating power of the Inverter, the Inverter may shut down automatically.
- The Inverter may automatically shut down if its internal temperature gets too high.Note: Even though this Inverter has built-in mechanisms to minimize damage,
these situations should be avoided because they can still damage the Inverter or battery.
- Place the Inverter on a dry, level, non-flammable, stable surface. Make sure the Inverter has adequate ventilation and is not in direct sunlight.
- Connect one end of a ground wire (not included, use at least recommended wire thickness from specification table) to the Ground Terminal located on the back of the Inverter. Then connect the other end of the ground wire to a paint/rust free grounded metal surface, grounding rod, or other appropriate ground source3. Battery Type
- Selection: Use only deep cycle lead-acid batteries with this Inverter, such as 12 volt marine/RV deep-cycle batteries. DO NOT use automotive, engine starting (SLI), or maintenance-free wet cell batteries with this Inverter; they are designed for repeated, shallow discharge and will wear out quickly.Gel and AGM (Absorbed Glass Mat) batteries can be used with this Inverter, but they require special charging procedures. Refer to battery supplier’s instructions.
- Battery capacity selection:
Inverter Output| about 1 hour
discharge time (Minimum battery capacity)
| about 4 hour
discharge time (Optimal battery capacity)
---|---|---
500W| 80 Ah| 200 Ah
1000W| 150 Ah| 400 Ah
1500W| 240 Ah| 700 Ah
2000W| 300 Ah| 1000 Ah
3000W| 450 Ah| 1500 Ah
4000W| 600 Ah| 2000 Ah
5000W| 750 Ah| 2500 Ah
Consult the chart above for approximate run time at different battery capacities. If the battery does not have a capacity this large individually, use a bank of batteries as explained below.5. Battery Bank assembly instructions:
-
Read the following safety rules before assembling the battery bank:
-
Connect batteries in parallel (negative terminals together to one cable; positive terminals together to the other cable) as shown in Battery Bank Example ONLY.
-
Do not connect 12 V batteries in series (from negative of one battery to the positive of the next).
-
This connection can result in voltage high enough to cause ELECTROCUTION. Wear splash-resistant ANSI-approved safety goggles and electrically insulated gloves while assembling battery bank.
-
Only connect similar batteries together in a battery bank. Do not connect old and new batteries together, flooded and gel cells together, or batteries of different capacities together.
-
Connect all batteries in the battery bank together using cables of the thickness recommended in the specification table or thicker. Since amp draw on this low-voltage circuit will be very high, thinner cables present a fire hazard.
-
Locate battery bank in a clean, well-ventilated area, away from ignition sources and flammable materials. Batteries release explosive hydrogen gas while charging.
-
Charge, store, and maintain batteries according to the supplier’s instructions.
-
Connect the batteries in parallel as shown above. Connect all of the positive terminals to one another.
-
Then connect all the negative terminals to one another.
-
Connect the negative and positive output cables to opposite ends of the bank. Use two 2/0 AWG cables up to 3 feet long in parallel on each terminal. Do not allow the output cables to touch one another.
-
Test the voltages at the output cables to help ensure that the battery bank is properly wired. If the voltage is higher than 13 volts, then part of the battery bank is likely connected in series (a negative terminal of one battery attached to a positive terminal of another) instead of in parallel. Carefully examine the diagram and correct
the wiring before attaching to the Inverter. -
Turn the Inverter’s Switch off.
-
Connect the output cables from the battery bank to the Inverter.
Operating Instructions
- Plug 120 VAC device(s) into the receptacles. Switch all devices off. The devices must not use more than the rated wattage during continuous operation, otherwise they may overload the Inverter.
- Turn the Inverter’s Switch on.
- Turn the device(s) on, one at a time. If the alarm sounds, turn off the device(s). Unplug the device(s) from the Inverter. Check the wattage of the devices, if there were multiple devices plugged in, discontinue use of one or more. If a single device set the alarm off, it is not appropriate for use with the Inverter.
- Inverter will consume some power while on, even without loads attached. Turn Inverter off after use.
Typical Device Power Consumption
Product| Wattage| | Product| Wattage| | Product|
Wattage
---|---|---|---|---|---|---|---
Laptop| 50| Belt Sander| 350| Chest Freezer| 800
Stereo| 200| 3/8″ Drill| 350| Coffee Maker| 850
Mixer| 200| Blender| 350| Iron| 1050
Table Fan| 200| Laser Printer| 400| Mini Microwave| 1200
TV-VCR| 250| Food Processor| 400| Hair Dryer| 1200
Computer| 250| Reciprocating Saw| 600| 10″ Saw| 1350
Small Refrigerator| 350| AC (5,000 BTU)| 700|
Jigsaw| 350| Vacuum| 750
Note: The above chart is intended as a general guideline only — actual device wattage requirements will vary. Some devices listed above may require a pure sine wave Inverter instead for proper operation.
Maintenance and Servicing
Procedures not specifically explained in this manual must be performed only by
a qualified technician.TO PREVENT SERIOUS INJURY FROM ELECTRIC SHOCK:
Turn the Inverter off and disconnect its power supply before performing any
inspection, maintenance, or cleaning procedures.TO PREVENT SERIOUS INJURY FROM
INVERTER FAILURE:
Do not use damaged Inverter. If abnormal noise, vibration, or heating occurs,
have the problem corrected before further use.Wear splash-resistant ANSI-
approved safety goggles and electrically insulated gloves while working near
batteries.
- BEFORE EACH USE, inspect the general condition of the Inverter. Check for:
- loose hardware
- damaged electrical wiring
- cracked or broken parts
- any other condition that may
- affect its safe operation.
- AFTER USE, clean external surfaces of the Inverter with clean, dry cloth.
- Maintain batteries according to manufacturer’s instructions. Check electrolyte level on all batteries after charging and refill as needed. Charge batteries according to manufacturer’s recommendations ONLY; incorrect charging may cause battery damage or explosion.
- DO NOT OPEN HOUSING. Contains no user-serviceable parts. Internal parts may be electrified, even with Inverter off and power disconnected.
- Store the Inverter in a clean, dry, safe location out of reach of children and other unauthorized people.
- Internal electronic components must be disposed of properly or recycled.
FCC
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Troubleshooting
Problem | Possible Causes | Probable Solutions |
---|---|---|
Inverter shuts off during use. | 1. Excessive load at output. |
2. Internal temperature is too high.
| 1. Reduce load to less than rated power.
2. Let the Inverter cool down for at least 30 minutes.
Make sure that the fan is not blocked and that the Inverter has sufficient ventilation.
No output voltage.| 1. Cords not connected properly.
2. Fuse on battery bank open.
3. Internal fuse(s) open.
4. Low input voltage.
5. Loose or corroded connection.
6. High input voltage.
| 1. Check and secure connections.
2. Check battery bank fuse and replace as needed.
3. Have technician check internal fuses and replace as needed.
Only a qualified technician should open housing.
4. Recharge or replace battery.
5. Clean and tighten connection.
6. Remove charging source and make sure correct battery is being used and connected correctly.
Output voltage is incorrect.| Input voltage is too high or too low.| Maintain
input voltage at required level.
Could not drive load.| 1. Load power is too large.
2. The AWG of the wire is too low.
3. Start power of a device is up to twice the rated power.
| 1. Lower load level.
2. Use appropriately-sized wire connections.
3. Reduce load, or change devices.
Motor-operated device operates at incorrect speed.| Load is only inductive.|
Operate a lamp or heater at the same time to provide a more balanced load.
Television picture is full of static or speakers make a buzz.| 1. Television
or radio interference.
2. Incompatible device.
| 1. Move Inverter away from antenna and/ or use a shielded antenna cable.
2. Contact device supplier to make sure that device can operate on Modified Sine Wave Power.
Follow all safety precautions whenever diagnosing or servicing the Inverter. Disconnect power supply before service.
Limited 90-Day Warranty
Harbor Freight Tools Co. makes every effort to assure that its products meet
high quality and durability standards, and warrants to the original purchaser
that this product is free from defects in materials and workmanship for the
period of 90 days from the date of purchase. This warranty does not apply to
damage due directly or indirectly,
to misuse, abuse, negligence or accidents, repairs or alterations outside our
facilities, criminal activity, improper installation, normal wear and tear, or
to lack of maintenance. We shall in no event be liable for death, injuriesto
persons or property, or for incidental, contingent, special or consequential
damages arising from the use of our product. Some states do not allow the
exclusion or limitation of incidental or consequential damages, so the above
limitation of exclusion may not apply to you.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.
To take advantage of this warranty, the product or part must be returned to us
with transportation charges prepaid. Proof of purchase date and an explanation
of the complaint must accompany the merchandise. If our inspection verifies
the defect, we will either repair or replace the product at our election or we
may elect to refund the purchase price if we cannot readily and quickly
provide you with a replacement. We will return repaired products at our
expense, but if we determine there is no defect, or that the defect resulted
from causes not within the scope of our warranty, then you must bear the cost
of returning the product. This warranty gives you specific legal rights and
you may also have other rights which vary from state to state.