ecler eIC5154 In-Ceiling Loudspeakers User Manual
- June 5, 2024
- ecler
Table of Contents
eIC5154
IN-CEILING LOUDSPEAKERS
EN 54-24 Certified In-ceiling / In-wall Loudspeake
USER MANUAL
IMPORTANT REMAR
WARNING: SHOCK HAZARD -DO NOT OPEN
** The lightning flash with the arrowhead symbol, within an equilateral
triangle, is intended to alert the user to the presence of uninsulated
“dangerous voltage” within the product’s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the
user to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance
WARNING (If applicable):** The terminals marked with the symbol may be of
sufficient magnitude to constitute a risk of electric shock. The external
wiring connected to the terminals requires installation by an instructed
person or the use of ready-made leads or cords
WARNING: To prevent fire or shock hazards, do not expose this equipment
to rain or moisture.
WARNING: An apparatus with Class I construction shall be connected to a
mains socket-outlet with a protective earthing connection.
IMPORTANT SAFETY INSTRUCTIONS
- Read these instructions.
- Keep these instructions.
- Heed all warnings.
- Follow all instructions.
- Do not use this apparatus near water.
- Clean only with a dry cloth.
- Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
- Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat
- Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for the replacement of the obsolete outlet.
- Protect the power cord from being walked on or pinched particularly at the plugs, convenience receptacles, and at the point where they exit from the apparatus.
- Only use attachments/accessories specified by the manufacturer.
- Unplug the apparatus during lightning sorts or when unused for long periods of time.
- Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way, such as a power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
- Disconnecting from mains: When switching off the POWER switch, all the functions and light indicators of the unit will be stopped, but fully disconnecting the device from the mains is done by unplugging the power cable from the mains input socket. For this reason, it always shall remain easily accessible.
- Equipment is connected to a socket-outlet with earthing connection by means of a power cord.
- The marking information is located at the bottom of the unit.
- The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus
NOTE: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
WARNING: This product must not be discarded, under any circumstance, as
unsorted urban waste. Take to the nearest electrical and electronic waste
treatment center.
NEEC AUDIO BARCELONA, S.L. accepts no liability for any damage that may
be caused to people, animals,s or objects due to failure to comply with the
warnings above.
IMPORTANT NOTE
Thank you for choosing our Ecler eIC5154 EN 54-24 certified in-ceiling/in-
wall loudspeaker!
It is VERY IMPORTANT to carefully read this manual and to fully understand
its contents before any connection in order to maximize your use and get the
best performance from this equipment.
To ensure optimal operation of this device, we strongly recommend that its
maintenance be carried out by our authorized Technical Services.
Ecler eIC5154 comes with a 3-year warranty.
INTRODUCTION
ECLER eIC5154 is a cost-effective in-ceiling loudspeaker that features a design that conforms to EN54-24 standard (Fire detection and fire alarm systems, Voice alarms – Loudspeakers). It performs a 5” woofer.
Applications
- Corporate and residential buildings
- Commercial premises
- Leisure centres
- Health and sports centres
- Meeting and conference rooms
- Auditoriums, museums
MAIN CHARACTERISTICS:
- One-way ABS speaker
- Power selector @ 100V 6/3/1,5/0,75/0,38 W
- 5” woofer
- Available in traffic white (RAL 9016)
- EN 54-24:2008 certified
CONNECTION
Step A: open the loudspeaker from the clamp as shown in the picture.
Step B: release the spring to open the fireproof dome.
Step C : pass the audio cable through the wire clamp.
Step D: connect the loudspeaker wire according to the requirement in the label. Then install the loudspeaker.
INSTALLATION
Step 1 : measure the mounting hole. It must be the cut-out size of the device. Pass the cable through the cable gland. Follow steps A, B & C.
Step 2 : lose the metal plates and raise them up to the top. Insert the back can into the mounting hole.
Step 3: slide down the metal plates until they reach the surface. Tight the fasteners inside the back can.
Step 4: follow step D. Then connect the audio cable to the loudspeaker’s terminal block. Finally, insert the mounting springs into the hooks and push the loudspeaker into the back can.
TECHNICAL DATA
eIC5154
Effective frequency range’
Coverage angle2
Sensitivity’
Power options| 120 Hz-20 kHz
165°x165° (HxV)
92 (1W/1m)
100V: 6W / 3W/ 1,5W / 0,75W / 0,38W
70V: 3W/ 1,5W / 0,75W / 0,38W / 0,19W
---|---
Transducers
Ways
Driver| 1
5″ woofer
Physical
Installation options
Certifications
Enclosure material.
Finished color
Recommended cut-out diameter
Ceiling thickness
Dimensions (∅xD)
Weight| Ceiling
EN54-24
ABS
Traffic white (RAL 9016)
158 mm / 6.22″
No limit min
40mm / 1.57″ max
180x157mm / 7.09″x6.18″
1.2 kg / 2.65 lb
- 10dB below the sound pressure level at a specified sensitivity
- 6dB below the sound pressure level than that at the direction of maximum level, Average from 1 kHz to 4 kHz.
- Measured on-axis, far-field, and referenced to 1 meter by inverse square law. Average from 100 Hz to 10 kHz.
Circuit diagram
Mechanical diagram
Exploded view
NO, | Name | Specification |
---|---|---|
1 | Speaker shell | 5° black Speaker shell |
2 | Speaker | 5°Bass1565EN) |
3 | Metal film capacitance | 250V33UF No pole capadtatce -25’485° |
4 | Transponder | SH-565-1Y |
5 | Wire clamping device | _P69 |
Rear label
eIC5154
Type: A 17
Loudspeaker for voice alarm systems for fire detection and fire alarm systems
for buildings
Certified to EN 54-24:2008
Rated noise voltage: 100V
Freq.Range: 130Hz – 18KHz
SPL (1W/m): 92dB
1438-CPR-0516 Rated noise power: 6W
Taps: 6/3/1.5/0.75/0.38
Cutout size: 157mm
NEEC Audio Barcelona, S.L.
Motors 166-168, 08038 Barcelona, SPAIN
Made in China
Here is the Serial Number
Certification plate
NEEC Audio Barcelona St 17 1438-CPR-0516
EN 54-24:2008 Components of Voice Alarm System-Loudspeaker
Loudspeaker for voice alarm systems for fire detection and fire alarm systems
for buildings
Provided options: Type A
All product characteristics are subject to variation due to production
tolerances.
NEEC AUDIO BARCELONA S.L. reserves the right to make changes or improvements
in the design or manufacturing that may affect these product specifications.
For technical queries contact your supplier, or distributor or complete the
contact form on our website, in Support / Technical requests.
Motors, 166‐168 08038 Barcelona ‐ Spain ‐ (+34) 932238403 |
information@ecler.com |
www.ecler.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>