Notes regarding the operating manual

Symbols

Danger

This symbol indicates dangers to the life and health of persons due to extremely flammable gas.

Warning of electrical voltage

This symbol indicates dangers to the life and health of persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.

Caution

This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.

Note
This signal word indicates important information (e.g. material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the operating manual must be observed.

You can download the current version of the operating manual and the EU declaration of conformity via the following link:

TTK 120 E

https://hub.trotec.com/?id=42894

TTK 122 E

https://hub.trotec.com/?id=42895

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use.

Warning

Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

  • Do not use the device in potentially explosive rooms or areas and do not install it there.

  • Do not use the device in aggressive atmosphere.

  • Only put up the device in an upright, stable position on firm ground.

  • Let the device dry out after a wet clean. Do not operate it when wet.

  • Do not use the device with wet or damp hands.

  • Do not expose the device to directly squirting water.

  • Never insert any objects or limbs into the device.

  • Do not cover the device during operation.

  • Do not sit on the device.

  • This appliance is not a toy. Keep away from children and animals. Do not leave the device unattended during operation.

  • Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts.

  • Ensure that all electric cables outside of the device are protected from damage (e.g. caused by animals). Never use the device if electric cables or the power connection are damaged!

  • The mains connection must correspond to the specifications in the Technical annex.

  • Insert the mains plug into a properly fused mains socket.

  • Observe the device’s power input, cable length and intended use when selecting extensions to the power cable. Completely unroll extension cables. Avoid electrical overload.

  • Before carrying out maintenance, care or repair work on the device, remove the mains plug from the mains socket. Hold onto the mains plug while doing so.

  • Switch the device off and disconnect the power cable from the mains socket when the device is not in use.

  • Do not under any circumstances use the device if you detect damages on the mains plug or power cable.
    If the power cable is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
    Defective power cables pose a serious health risk!

  • When positioning the device, observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical annex.

  • Make sure that the air inlet and outlet are not obstructed.

  • Make sure that the suction side is kept free of dirt and loose objects.

  • Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition.

  • Only transport the device in an upright position with an emptied condensation tank or drain hose.

  • Discharge the collected condensate before transport and storage. Do not drink it. Health hazard!

Safety warnings for devices containing flammable refrigerants

  • Only position the device in rooms where potentially leaking refrigerant cannot accumulate.
  • Only position the device in rooms where there is no source of ignition (e.g. open flames, an active gas appliance or an electric heater).
  • Please note that the refrigerant is odourless.
  • Only install the device in compliance with the national installation regulations.
  • Observe the national gas regulations.
  • Only install, operate and store the device TTK 120 E /TTK 122 E in a room measuring more than 4 m2
  • Store the device in a way that no mechanical damage can occur.
  • Please note that the connected pipelines must not contain any sources of ignition.
  • R290 is a refrigerant that complies with European environmental regulations. No part of the cooling circuit may be perforated.
  • Observe the maximum refrigerant capacity in the technical data.
  • Do not drill through or burn.
  • Do not use any means other than those recommended by the manufacturer for accelerating the defrosting process.
  • Every person working with or at the refrigerant circuit must be able to provide a certificate of qualification issued by a body accredited by the industry, demonstrating their competence in the safe use of refrigerants based on a procedure well-known in the industry.
  • Service work may only be carried out in accordance with the manufacturer’s specifications. If maintenance and repair work require the support of additional persons, the person trained in handling flammable refrigerants shall continuously supervise the work carried out.
  • Unventilated rooms, in which the device is installed, operated or stored, must be built in a way to ensure that potentially leaking refrigerant cannot accumulate. This serves to avoid fire or explosion hazards resulting from an ignition of the refrigerant by an electric furnace, cooking stove or another ignition source.
  • The entire refrigerant circuit is a maintenance-free, hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air conditioning or by Trotec.

Intended use

Only use the device for drying and dehumidifying room air, while adhering to and following the technical data.
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry.

Intended use comprises:

  • dehumidifying and drying:
    – living rooms, bedrooms, bathrooms and basements
    – laundries, holiday homes, camper vans, boats

  • maintaining the dryness of:
    – storage spaces, archives, laboratories, garages
    – bathrooms, wash rooms, changing rooms etc.

Foreseeable misuse

The device is not intended for industrial use.

  • Do not place the device on wet or flooded ground.
  • Do not place any objects, e.g. clothing, on the device.
  • Do not use the device out of doors.
  • Do not make any unauthorised modifications, alterations or structural changes to the device.
  • Any use other than the intended use is regarded as a reasonably foreseeable misuse.

Personnel qualifications

People who use this device must:

  • be aware of the dangers that occur when working with electric devices in damp areas.
  • have read and understood the operating manual, especially the Safety chapter.

Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by Trotec.

Safety signs and labels on the device

Note

Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition.

The following safety signs and labels are attached to the device:

TTK 120 E / TTK 122 E

Follow the manual

This symbol indicates that the operating manual must be observed.

Follow the repair manual

Disposal, maintenance and repair work of the refrigerant circuit may only be carried out in accordance with the manufacturer’s specifications and by persons having a certificate of qualification. A corresponding repair manual is available from the manufacturer upon request.

Residual risks

Danger

Natural refrigerant propane (R290)!

H220 – Extremely flammable gas.
H280 – Contains gas under pressure; may explode if heated.

P210 – Keep away from heat, sparks, open flames and other ignition sources. No smoking.
P377 – Leaking gas fire: Do not extinguish, unless leak can be stopped safely.
P410+P403 – Protect from sunlight. Store in a well ventilated place.

Warning of electrical voltage

Work on the electrical components must only be carried out by an authorised specialist company!

Warning of electrical voltage

Before any work on the device, remove the mains plug from the mains socket!
Do not touch the mains plug with wet or damp hands.
Hold onto the mains plug while pulling the power cable out of the mains socket.

Warning

Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way!
Observe the personnel qualifications!

Warning

The device is not a toy and does not belong in the hands of children.

Warning

Risk of suffocation!
Do not leave the packaging lying around. Children may use it as a dangerous toy.

Note

Do not operate the device without an air filter inserted into the air inlet!
Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.

Behaviour in the event of an emergency

  1. Switch the device off.
  2. In an emergency, disconnect the device from the mains feed-in: Hold onto the mains plug while pulling the power cable out of the mains socket.
  3. Do not reconnect a defective device to the mains.

Information about the device

Device description

The device uses the principle of condensation to automatically dehumidify rooms.
The fan sucks damp room air through the air inlet, the air filter, the evaporator and to the condenser located behind it. The air is cooled at the cold evaporator until it is below the dew point. Water vapour contained in the room air precipitates on the evaporator fins as condensation or rime. The dehumidified, cooled air is slightly warmed at the condenser and blown out again. The drier air thus conditioned mixes with the air in the room. The humidity in the room where the device is positioned is reduced as air constantly circulates through the device.
Depending on the air temperature and the relative humidity, the condensed water either drops continuously or only during the defrost phase through the integrated drain nozzle into the condensation tank below. It is fitted with a float to measure the filling level.
The device has a control panel for operating and controlling the functions.
Once the maximum filling level of the condensation tank is reached or in case the condensation tank is not installed correctly, the condensation tank indicator light (see chapter Operation) on the control panel is illuminated. The device switches off. The condensation tank indicator light only goes out again once the emptied condensation tank is reinserted.
Optionally, the condensed water can be drained by attaching a hose at the condensation connection.
The device can reduce the relative humidity of a room to approx. 30 %.
In addition, the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces.
Because of the heat radiation generated during operation, the room temperature may rise slightly.

Device depiction

TROTEC TTK 120 E Comfort dehumidifier - Device
depiction

Transport and storage

Note

If you store or transport the device improperly, the device may be damaged.
Note the information regarding transport and storage of the device.

Transport

Please note that additional transport regulations might apply to devices containing flammable refrigerants. The equipment’s arrangement and the maximum number of components to be transported together can be gathered from the applicable transport regulations.
To make the device easier to transport, it is fitted with a carry handle.
To make the device easier to transport, it is fitted with wheels.

Before transporting the device, observe the following:

  • Switch the device off.
  • Hold onto the mains plug while pulling the power cable out of the mains socket.
  • Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance).
  • Do not use the power cable to drag the device.
  • Only wheel the device on a level and smooth surface.

After transporting the device, proceed as follows:

  • Set up the device in an upright position after transport.
  • Leave the device to rest for 12 to 24 hours, so the refrigerant can accumulate within the compressor.
    Wait 12 to 24 hours before switching the device back on!
    Acting contrary might lead to compressor damage and a malfunctioning device. If so, any warranty claims will be voided.

Storage

Before storing the device, observe the following:

  • Drain the remaining condensate from the device and the condensation drain hose (see chapter Maintenance).
  • Hold onto the mains plug while pulling the power cable out of the mains socket.

When the device is not being used, observe the following storage conditions:

  • Only store the device in a room measuring more than 4 m2.
  • dry and protected from frost and heat
  • in an upright position where it is protected from dust and direct sunlight
  • with a cover to protect it from invasive dust, if necessary
  • Place no further devices or objects on top of the device to prevent it from being damaged.

Assembly and installation

Scope of delivery

  • 1 x Device
  • 1 x Air filter
  • 1 x Activated carbon filter
  • 1 x Condensation drain hose, diameter: 16 mm
  • 1 x Manual

Unpacking the device

  1. Open the cardboard box and take the device out.
  2. Completely remove the packaging.
  3. Fully unwind the power cable. Make sure that the power cable is not damaged and that you do not damage it during unwinding.

Start-up

When positioning the device, observe the minimum distance from walls or other objects as described in the chapter Technical annex.

  • Before restarting the device, check the condition of the power cable. If there are doubts as to the sound condition, contact the customer service.
  • Only position the device in rooms where potentially leaking refrigerant cannot accumulate.
  • Only position the device in rooms where there is no source of ignition (e.g. open flames, an active gas appliance or an electric heater).
  • Only put up the device in an upright, stable position on firm ground.
  • Do not create tripping hazards when laying the power cable or other electric cables, especially when positioning the device in the middle of the room. Use cable bridges.
  • Make sure that extension cables are completely unrolled.
  • When positioning the device, keep a sufficient distance to heat sources.
  • Make sure that no curtains or other objects interfere with the air flow.
  • When positioning the device, particularly in wet areas, secure it locally with an RCD (residual current device) which complies with the respective regulations.

Inserting the air filter

Note

Do not operate the device without an air filter inserted into the air inlet!
Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device.

  • Make sure that the air filter is installed before switching the device on.

Inserting the condensation tank

  • Ensure that the float inside the condensation tank is inserted correctly.
  • Ensure that the condensation tank is empty and inserted correctly.

Connecting the power cable

  • Insert the mains plug into a properly secured mains socket.

Operation

Notes:

  • Avoid open doors and windows.
  • After being switched on, the device operates fully automatically.
  • The fan permanently runs in dehumidification mode even after the set nominal value has been reached until the device is switched off.

Operating elements

TROTEC TTK 120 E Comfort dehumidifier - Operating
elements

TROTEC TTK 120 E Comfort dehumidifier - Operating elements
2

Switching the device on

Once you have completely installed the device as described in the chapter Assembly and start-up, you can switch it on.

  1. Press the On/Off button (19).
    ⇒The On/Off LED (18) is illuminated.
    ⇒The device starts to dehumidify.

Setting the operating mode

  • Dehumidification
  • Continuous operation
  • Drying laundry
  • Ventilation

dehumidification

The device keeps running until reaching the desired relative room humidity. Then the compressor switches off and the fan keeps running. Once the desired relative room humidity is exceeded, the compressor switches back on.
The desired relative room humidity can be set at any time within a setting range of 30 % to 90 %.
You can choose between low and high fan speed (laundry drying function).
Please proceed as follows to activate the dehumidification mode:

  1. Press the Mode button (24) until the dehumidification LED (9) is illuminated.
  2. Press the Speed button (23) to set the desired fan stage.
    ⇒ If the fan speed is set to a low level, the Speed LED (12) of stage 1 is illuminated.
    ⇒ If the fan speed is set to a high level, the Speed LED (12) of stage 2 is illuminated.

Setting the desired relative room humidity

  1. Use the plus (21) or minus (22) buttons to select the desired relative humidity value. Setting is possible in the range between 30 % and 90 %.
    ⇒ The desired relative room humidity is shown on the control panel (13) for approx. 5 seconds. Then the current relative room humidity is displayed again.

Continuous operation

Please proceed as follows to set continuous operation:

√ The dehumidification mode is activated.

  1. Press the plus button (21) and set the relative humidity level to above 90 %.
    ⇒ “Co” is indicated on the control panel.
    ⇒ Continuous operation is activated.

  2. If you press the minus button (22) and set the relative humidity level to below 90 %, continuous operation is deactivated.
    ⇒ The device switches to dehumidification mode.

Info

For continuous operation a condensation drain hose can be connected in order to continuously drain the accumulating condensate.

Laundry drying function

This special function improves the clothes drying process by continuous operation of the dehumidifier at full capacity.
Please proceed as follows to adjust the laundry drying function:

  1. Press the Mode button (24) until the laundry drying LED (10) is illuminated.
    ⇒ The device dehumidifies the air constantly and regardless of the room humidity.
    ⇒ The room humidity and the fan speed cannot be set in this operating mode.

Ventilation

Using this function you can change between a low and a high fan speed.

  1. Press the Mode button (24) until the ventilation LED (11) is illuminated.
  2. Press the Speed button (23) to set the desired fan stage.
    ⇒ If the fan speed is set to a low level, the Speed LED (12) of stage 1 is illuminated.
    ⇒ If the fan speed is set to a high level, the Speed LED (12) of stage 2 is illuminated.

Setting the timer

Note

The device must not be left unattended in a freely accessible room with an activated timer.

The timer has two modes of operation:

  • Automatic switch-on upon expiry of a preset number of hours
  • Automatic switch-off upon expiry of a preset number of hours

The function can be set in addition in all operating modes. The number of hours can be set in hourly increments (1 h to max. 24 h).

Automatic switch-on

√ The device is now in standby mode.

  1. Repeatedly press the timer button (20) until the desired number of hours is displayed.
    ⇒ The set number of hours appears on the control panel indicates the remaining (13).
    ⇒ After the predefined time, the device switches itself on.

Notes regarding automatic switch-on:

  • Manually switching the device on disables the automatic switch-on function.
  • If you select 00 hours, the timer will be off.

Automatic switch-off

√The device is switched on.

  1. Repeatedly press the timer button (20) until the desired number of hours is displayed.
    ⇒ The set number of hours appears on the control panel indicates the remaining (13).
    ⇒ The device switches off after the predefined time.

Notes regarding automatic switch-off:

  • Manually switching the device off disables the automatic switch-off function.
  • If you select 00 hours, the timer will be off.

Auto stop function

If the condensation tank is full, not inserted correctly or the desired relative room humidity has been reached, the device will stop automatically. The Condensation tank full LED (17) is illuminated. In addition, the device emits an acoustic signal several times.

Memory function

After a power failure during operation the device will automatically be switched back on.

The previous settings are saved except for the timer.

Locking function

Please proceed as follows to activate the locking function:

  1. Press the Mode button (24) for 5 seconds.
    ⇒ The locking function is activated.

  2. Press the Mode button (24) for 5 seconds again to disable the child lock.
    ⇒ Now all buttons can be actuated as usual.

Indication of the room temperature

Proceed as follows to display the room temperature:

  1. Simultaneously press the plus (21) and minus (22) buttons.
    ⇒ The current room temperature will be indicated on the control panel (13).

Operation with hose attached to the condensation connection

For continuous operation or unattended dehumidification, please connect a suitable condensation drain hose to the device.

√ The supplied hose (diameter = 16 mm) and the metal clamp are ready for use.
√ The device is switched off.

  1. Remove the condensation tank.
    ⇒ Make sure not to damage the float when removing the condensation tank.
    TROTEC TTK 120 E Comfort dehumidifier - Remove the condensation
tank

  2. Push one end of the hose onto the hose connection.
    TROTEC TTK 120 E Comfort dehumidifier - Push one end of the hose onto the
hose connection.

  3. Secure the end of the hose with a metal clamp.

TROTEC TTK 120 E Comfort dehumidifier - Secure the end of the hose with a
metal clamp

  1. Guide the other hose end to a suitable drain or sufficiently dimensioned collection container. Please note that the hose must not be kinked.
    ⇒The device can now be switched on.

TROTEC TTK 120 E Comfort dehumidifier - The device can now be switched
on

Automatic defrost by means of hot gas feed

At low ambient temperatures, ice may form at the evaporator during dehumidification. The device then carries out an automatic defrost by means of the hot gas feed. Here, a hot cooling agent is led into the iced evaporator for its surfaces to defrost.

The hot gas automatic defrost system integrated in the device automatically switches on the defrost cycle at regular intervals.
The automatic defrost LED (16) is illuminated throughout the defrost process.

The duration of the defrost process can vary. Do not switch off the device during automatic defrost. Do not remove the mains plug from the mains socket.

Drying laundry

In addition, the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces.
When positioning the device or a clothes horse, please observe the minimum distances specified in the technical data.
For drying laundry the following values should be selected:

  • cupboard dry = 46 % relative humidity
  • iron dry = 58 % relative humidity
  • slightly dried = 65 % relative humidity

If necessary, use a measuring device to determine the humidity level.

Shutdown

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

  • Switch off the device.
  • Hold onto the mains plug while pulling the power cable out of the mains socket.
  • If necessary, remove the condensation drain hose and any residual fluid from it.
  • Empty the condensation tank, if need be.
  • Clean the device according to the Maintenance chapter.
  • Store the device according to the Transport and storage chapter.

Errors and faults

The device has been checked for proper functioning several times during production. If malfunctions occur nonetheless, check the device according to the following list.

The device does not start:

  • Check the power connection.
  • Check the power cable and mains plug for damage.
  • Check the on-site fusing.
  • Check the filling level of the condensation tank and empty it if necessary. The condensation tank full LED (17) must not be illuminated on the control panel.
  • Check the condensation tank for correct seating.
  • Check the room temperature. Observe the device’s permissible operating range according to the technical data.
  • Wait for 10 minutes before restarting the device. If the device is not starting, have the electrics checked by a specialist company or by Trotec.

The device is running, but there is no formation of condensate:

  • Check the float in the condensation tank for dirt. If necessary, clean the condensation tank. The float must be able to move freely
  • Ensure that the relative room humidity complies with the technical data.
  • Check the preselected relative room humidity. The humidity in the room must be above the selected range.
  • Check the air filter for dirt. If necessary, clean or replace the air filter.
  • From the outside, check the condenser for dirt (see chapter Maintenance). If the condenser is dirty, have it cleaned by a specialist company or by Trotec.
  • The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify.

The device is loud or vibrates:

  • Check whether the device is set up in a stable and upright position.

Condensate is leaking:

  • Check the device for leaks.

The compressor does not start:

  • Check the room temperature. Observe the device’s permissible operating range according to the technical data.
  • Ensure that the relative room humidity complies with the technical data.
  • Check the preselected relative room humidity. The humidity in the room must be above the selected range.
  • Check whether the overheating protection of the compressor has tripped. Disconnect the device from the mains and let it cool down for approx. 10 minutes before reconnecting it.
  • The device might carry out an automatic defrost. During automatic defrost, the device does not dehumidify.

The device gets very warm, is loud or is losing performance:

  • Check the air inlets and air filters for dirt. Remove external dirt.
  • From the outside, check the device for dirt (see chapter Maintenance). If the inside of the device is dirty, have it cleaned by a specialist company for cooling and air conditioning or by Trotec.

Note
Wait for at least 3 minutes after maintenance and repair work. Only then switch the device back on.

The device still does not operate correctly after these checks:

Please contact the customer service. If necessary, bring the device to a specialist company for cooling and air-conditioning or to Trotec for repair.

Error codes

The following error codes can be indicated on the control panel:

TROTEC TTK 120 E Comfort dehumidifier - Error codes

Maintenance

Maintenance intervals

TROTEC TTK 120 E Comfort dehumidifier - Maintenance

Maintenance and care log

TROTEC TTK 120 E Comfort dehumidifier - Maintenance and care
log

Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

  • Switch the device off.
  • Hold onto the mains plug while pulling the power cable out of the mains socket.

Warning of electrical voltage

Tasks which require the device to be opened must only be carried out by authorised specialist companies or by Trotec.

Refrigerant circuit

Danger

Natural refrigerant propane (R290)!

H220 – Extremely flammable gas.
H280 – Contains gas under pressure; may explode if heated.

P210 – Keep away from heat, sparks, open flames and other ignition sources. No smoking.
P377 – Leaking gas fire: Do not extinguish, unless leak can be stopped safely.
P410+P403 – Protect from sunlight. Store in a well ventilated place.

  • The entire refrigerant circuit is a maintenance-free, hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air conditioning or by Trotec.

Safety signs and labels on the device

Check the safety signs and labels attached to the device at regular intervals. Replace illegible safety signs!

Cleaning the housing

Clean the housing with a soft, damp and lint-free cloth. Make sure that no moisture enters the housing. Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth.

Visual inspection of the inside of the device for dirt

  1. Remove the air filter.
  2. Use a torch to illuminate the openings of the device.
  3. Check the inside of the device for dirt.
  4. If you see a thick layer of dust, have the inside of the device cleaned by a specialist company for cooling and air conditioning or by Trotec.
  5. Put the air filter back in.

TROTEC TTK 120 E Comfort dehumidifier - Put the air filter back
in

Cleaning the air filter and changing the activated carbon filter

Note
Ensure that the air filter is not worn or damaged. The corners and edges of the air filter must not be deformed or rounded. Before reinserting the air filter, make sure that it is undamaged and dry!

Note
Do not operate the device without an inserted activated carbon filter and air filter!

Note
The activated carbon filter cannot be washed and must be replaced if necessary.

Note
The lifetime of the activated carbon filter depends on the ambient conditions and the application period of the device.

  • The activated carbon filter must be cleaned or replaced if it is very dirty. This is brought to light e.g. by a reduced capacity (see chapter Errors and faults).
  • Make sure that the air filter and the activated carbon filter are installed before switching the device on.

The air filter has to be cleaned as soon as it is dirty. This is brought to light e.g. by a reduced capacity (see chapter Errors and faults).

If required, visually inspect the filters for dirt.

√ The device is switched off.
√ The device is disconnected from the mains.

  1. Remove the air inlet by loosening and removing both screws.

  2. Remove the air filter.
    TROTEC TTK 120 E Comfort dehumidifier - Remove the air
filter

  3. Clean the filter using a slightly damp, soft, lint-free cloth. If the filter is heavily contaminated, clean it with warm water mixed with a neutral cleaning agent.
    TROTEC TTK 120 E Comfort dehumidifier - Clean the filter using a slightly
damp

  4. Allow the filter to dry completely. Do not insert a wet filter into the device!

  5. Remove the activated carbon filter.

  6. Clean the activated carbon filter with a dry, lint-free cloth or a hoover if it is slightly dirty.
    If heavily soiled, dispose of the activated carbon filter in accordance with the national regulations and remove the new activated carbon filter from the plastic cover.

  7. Insert the cleaned or the new activated carbon filter.

  8. Put the air filter back in.

  9. Refit the air inlet by inserting and tightening both screws.
    TROTEC TTK 120 E Comfort dehumidifier - Refit the air inlet by inserting and
tightening both screws

Emptying the condensation tank

If the condensation tank is full or not installed correctly, the condensation tank full LED (17) will be illuminated. The compressor and fan will switch off.

  1. Take the condensation tank out of the device.
    ⇒ Make sure not to damage the float when removing the condensation tank.

  2. Empty the condensation tank over a drain or sink.

  3. Rinse the condensation tank with clear water. Regularly clean the condensation tank using a mild cleaning agent (no detergent!).

  4. Refit the condensation tank into the device. Make sure not to damage the float when inserting the condensation tank.
    In doing so, make sure that the float is positioned correctly.
    In doing so, make sure that the condensation tank is inserted correctly, for otherwise the device cannot be switched back on.
    TROTEC TTK 120 E Comfort dehumidifier - Refit the condensation tank into the
device

Activities required after maintenance

If you want to continue using the device:

  • Leave the device to rest for 12 to 24 hours, so the refrigerant can accumulate within the compressor.
    Wait 12 to 24 hours before switching the device back on!
    Acting contrary might lead to compressor damage and a malfunctioning device. If so, any warranty claims will be voided.

  • Reconnect the device to the mains.
    If you do not intend to use the device for a considerable time:

  • Store the device according to the Transport and storage chapter.

Technical annex

Technical data

TROTEC TTK 120 E Comfort dehumidifier - Technical
annex

Wiring diagram

TROTEC TTK 120 E Comfort dehumidifier - Wiring diagram

Overview of spare parts

Note : The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual.

TROTEC TTK 120 E Comfort dehumidifier - Overview of spare
parts

Disposal

The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life. You will find collection points for free return of waste electrical and electronic equipment in your vicinity. The addresses can be obtained from your municipality or local administration. You can also find out about other return options that apply for many EU countries on the website https://hub.trotec.com/?id=45090. Otherwise, please contact an
official recycling centre for electronic and electrical equipment authorised for your country.

The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment.

Have the refrigerant (propane) disposed of appropriately and according to the national regulations by a company with the relevant certification (European Waste Catalogue 160504).

Trotec GmbH
Grebbener Str. 7
D-52525 Heinsberg
+49 2452 962-400
+49 2452 962-200
info@trotec.com
www.trotec.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals