TEQ
Precision Hot Air Station without Extractor Desk
This manual corresponds to the following references:
TESE-1QA (100V / 120V)
TESE-2QA ( 230V)

Packing List

The following items are included:

Features

JT / TE Work Screen
JT/TE offers an intuitive user interface that provides quick access to station parameters.
Default PIN: 0105

Menu Options

| Set the station parameters
---|---
| Set the tool parameters
| Display the hours worked in each cycle
| It is possible to choose the language from a list.
| Allows you to carry out an overall station reset restoring all the parameters to their default values.

Troubleshooting
Station troubleshooting is available on the product page at www.jbctools.com

Advanced Functionalities
To work with profiles it is essential to use RWB / RWS / RWT rework arms. The Rework Arms supports the Hot Air Heater maintaining the distance and position of the component.
In this mode, you can set up or edit as many as 25 profiles of temperature and airflow.

JBC TESE 1QA \(100V 120V\) Precision Hot Air Station -
Functionalities

By pressing Graphics in the main MENU, temperature and power figures in real-time are displayed. This helps you decide which nozzle to use to obtain the best quality solder joints. JBC TESE 1QA \(100V 120V\) Precision Hot Air
Station - Graphics Display

****| The first system to optimize traceability in soldering
– Get greater quality and control in your production
– Manage your whole soldering process remotely in real-time 4m 38s
---|---
| Export Graphics
Insert a USB flash drive into the USB-A connector to save your soldering process in CSV format.
| Station Update
Download the JBC Update File from www.jbctools.com/software.html
Insert the USB flash drive with the file downloaded to the station. Suction

JBC TESE 1QA \(100V 120V\) Precision Hot Air Station -
Fig

System Notifications
The following icons will be displayed on the screen’s status bar.

| USB fl ash drive is connected.| | Station software update.
Press INFO to start the process.
---|---|---|---
| The station is controlled by a PC.| **| Warning.
Press INFO for failure description.
| The station is controlled by a robot.| |
Error.**
Press INFO for failure description, the type of error, and how to proceed.

Adjustable Stand

Adjust the tool holder angle to suit your work position. JBC TESE 1QA \(100V
120V\) Precision Hot Air Station - Adjustable Stand

Operation Modes

  1. From the Tool Settings Menu, select the mode to activate the tool depending on the task.
    Tool button| Pedal (not included)
    ---|---
    JBC TESE 1QA \(100V 120V\) Precision Hot Air Station - Tool
button| JBC TESE 1QA \(100V 120V\)
Precision Hot Air Station - Pedal
    Press the start/stop button to blow hot air.| Press the Pedal (Ref. P-305) to blow hot air and release to stop.
  2. The tool stops blowing when pressing the start/stop button.
    If the stand is connected to the station and for safety, it will also stop when returned to the stand. JBC TESE 1QA \(100V 120V\) Precision Hot Air
Station - stand

Operation

1. Placing 2. Heating 3. Extracting

JBC TESE 1QA \(100V 120V\) Precision Hot Air Station -
Placing| JBC TESE 1QA \(100V 120V\)
Precision Hot Air Station - Heating| JBC TESE 1QA \(100V 120V\) Precision Hot Air Station -
Extracting
Position the extractor with the appropriate suction cup and press the suction button.| Heat the component.| The component lifts off automatically when the solder melts.

Protectors & Extractors (not included)

For small components ( fig. 1 and 2).
We recommend using the protector + tripod| For large components (fig. 3 and 4).
We recommend using the manual extractors
---|---
JBC TESE 1QA \(100V 120V\) Precision Hot Air Station - small
components| JBC TESE 1QA \(100V
120V\) Precision Hot Air Station - arge components

Pick & Place (not included)
This tool helps you place and remove SMDs of any size easily thanks to the suction pump.

Pick & Place
Ref. T260-A| Bent Needles Set
Ref. 0861660| Straight Needles Set
Ref. 0901546
---|---|---
| |

Operation
Choose the needle and the suction cup that best fits the component and start as follows:

JBC TESE 1QA \(100V 120V\) Precision Hot Air Station -
Operation

1. Suction 2. Release

Once the suction is activated, cover the pen hole with your finger and lift off the component. 3m 18s 3m 18s| Lift your finger to release the component.

Accessories (not included)

Protectors

JBC TESE 1QA \(100V 120V\) Precision Hot Air Station -
Tripods

No.| Ref.| AxB (mm)| AxB (in)| No.| Ref.| AxB (mm)| AxB (in)
---|---|---|---|---|---|---|---
| P3353| 4,3 x 3| 0.16 x 0.12| | P1249| 12 x 23| 0.47 x 0.9
| P3786| 5,2 x 5,2| 0.20 x 0.20| 44| P4000| 12,5 x 12,5| 0.49 x 0.49
| P3352| 5,2 x 7,5| 0.20 x 0.29| | P3354| 13,2 x 13,2| 0.52 x 0.52
| P3355| 5,2 x 9,5| 0.20 x 0.37| | P4025| 13,5 x 21,5| 0.53 x 0.85
| P3356| 6,2 x 4,2| 0.24 x 0.16| 48| P2230| 15 x 15| 0.59 x 0.59
| P3785| 7,2 x 7,2| 0.28 x 0.28| 60| P4010| 17 x 17| 0.67 x 0.67
| P3784| 8,2 x 8,2| 0.32 x 0.32| | P4005| 18 x 29| 0.71 x 1.14
| P4035| 9 x 13| 0.35 x 0.51| | P4030| 18,5 x 18,5| 0.73 x 0.73
| P4040| 9,5 x 19| 0.7 x 0.74| | P1068| 18,5 x 24| 0.73 x 0.94
| P4080| 9,5 x 21| 9.5 x 0.83| | P2685| 28,5 x 28,5| 1.12 x 1.12
32| P2220| 10 x 10| 0.39 x 0.39| | P4085| 31,5 x 31,5| 1.24 x 1.24
| P4045| 10,5 x 21| 0.14 x 0.82| | P2672| 33 x 46| 1.30 x 1.18
| P4090| 11 x 16| 0.43 x 0.63| | P4002| 50 x 50| 1.97 x 1.97
24| P2235| 12 x 17| 0.47 x 0.67| | P3357| 52,5 x 14| 2.06 x 0.55

Extractors

No.| Ref.| AxB (mm)| AxB (in)    No.| Ref.| AxB (mm)| AxB (in)
---|---|---|---|---|---|---
52| E2052| 20 X 20| 0.79 x 0.79| | E4015| 31,5 X 31,5| 1.24 x 1.24
64| E2064| 20 X 26| 0.79 x 1.02| | E2084| 33 X 33| 1.30 x 1.30
80| E2184| 24 X 24| 0.94 x 0.94| | E2100| 38 X 38| 1.50 x 1.50
| E2068| 27 X 27| 1.06 x 1.06| | E2124| 45 X 45| 1.77 x 1.77
| E4020| 28,5 X 28,5| 1.12 x 1.12| |

Tripods

Ref. øC (mm) øC (in)
T2050 39 1.53
T2250 85 3.35

Manual extractor

Ref. øD (mm) øD (in)
E2190 7 0.27

Using the Thermocouple type K

Connect a TC type K (PH218) to the station and use it as a protection or regulation sensor.
You can define its use mode by means of the “Ext TC mode” option in the “Tool” menu.
You can choose from two work modes :

Regulation: the station regulates the air temperature automatically to maintain the External Thermocouple (TC) temperature.| Protection: the station cuts the air supply off when the External Thermocouple (TC) temperature is reached.
---|---
JBC TESE 1QA \(100V 120V\) Precision Hot Air Station -
Regulation
IPC* does not recommend exceeding ramp-up rates over 3-4ºC / sec. (5-7ºF / sec) so as to reduce the risk of thermal stress on the PCB.

  • IPC was founded in the U.S. in 1957 as the Institute for Printed Circuits. JBC TESE 1QA \(100V 120V\) Precision Hot Air Station - Printed Circuits

Quick Nozzle Changer

Changing nozzles quickly and safely.
Turn the tool off and handle it with care. The heating element and the nozzle are still hot. JBC TESE 1QA \(100V 120V\) Precision Hot Air Station - Nozzle
Changer

Compatible Nozzles
TET works with TE nozzles. Find the model that best suits your soldering needs at www.jbctools.com

***** Ref. Shape Size (mm) Size (in)
* TN9209 Straight Ø 3 Ø 0.12
* TN9208 Straight Ø 4 Ø 0.16
* TN9080 Straight Ø 5 Ø 0.20
TN9787 Bent Ø 3 Ø 0.12
TN9785 Bent Ø 4 Ø 0.16
TN9782 Bent Ø 5 Ø 0.20
TN8851 Bent Ø 3 / 45º Ø 0.12 / 45º
TN8905 Bent Ø 4 / 45º Ø 0.16 / 45º
TN9561 Bent Ø 5 / 45º Ø 0.20 / 45º

Replacing the Heating Element

Only perform this operation when the element is cold and the unit is disconnected from the mains.

  1. Loosen the screw.
  2. Pull the heating element away from the handle.
  3. Connect the new heating element, ensuring it is pushed all the way in.
  4. Tighten the screw. JBC TESE 1QA \(100V 120V\) Precision Hot Air Station - Heating Element

Changing the TET Heater Hose Set

  1. Ensure that the tool is turned off.
  2. Use a spanner to unscrew the nut.
  3. Make sure that the new heater tube fits into the grooves in the socket.
  4. Tighten the screw. JBC TESE 1QA \(100V 120V\) Precision Hot Air Station - Heater Hose

Maintenance

Before carrying out maintenance, always allow the equipment to cool down.

JBC TESE 1QA \(100V 120V\) Precision Hot Air Station - Clean
periodically

  • Clean the station screen with a glass cleaner or a damp cloth.
  • Use a damp cloth to clean the casing and the tool. Alcohol can only be used to clean the metal parts.
  • Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool status.
  • Periodically check all cables and tubes.
  • Replace a blown fuse as follows:
    1. Pull off the fuse holder and remove the fuse. If necessary use a tool to lever it off.| 2. Insert the new fuse into the fuse holder and return it to the station.
    ---|---
    JBC TESE 1QA \(100V 120V\) Precision Hot Air Station - Fuse
holder| JBC TESE 1QA \(100V 120V\)
Precision Hot Air Station - Fuse
  • Replace any defective or damaged pieces. Use original JBC spare parts only.
  • Repairs should only be performed by a JBC-authorized technical service.

Safety

It is imperative to follow safety guidelines to prevent electric shock, injury, fire, or explosion.

  • Do not use the units for any purpose other than soldering or rework. Incorrect use may cause a fire.
  • The power cord must be plugged into approved bases. Be sure that it is properly grounded before use. When unplugging it, hold the plug, not the wire.
  • Do not work on electrically live parts.
  • The tool should be placed on the stand when not in use in order to activate the sleep mode. The soldering tip or nozzle, the metal part of the tool, and the stand may still be hot even when the station is turned off. Handle with care, including when adjusting the stand position.
  • Do not leave the appliance unattended when it is on.
  • Do not cover the ventilation grills. Heat can cause inflammable products to ignite.
  • Avoid flux coming into contact with skin or eyes to prevent irritation.
  • Be careful with the fumes produced when soldering.
  • Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working to avoid personal harm.
  • Utmost care must be taken with liquid tin waste which can cause burns.
  • This appliance can be used by children over the age of eight and also persons with reduced physical, sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning the use of the appliance and understand the hazards involved. Children must not play with the appliance.
  • Maintenance must not be carried out by children unless supervised.

Specifications

TEQ
Precision Hot Air Station without Extractor Desk
Ref. TESE-1QA 100V-120V 50/60Hz. Input fuse: 8A. Rated current: 7A
Ref. TESE-2QA 230V 50/60Hz. Input fuse: 4A. Rated current: 3A

Temperature selection: Room temp. 150 – 450 °C / 300 – 840 °F
Nominal power: 300W
Cool mode: Toff. Used to blow air to room temperature
Ambient operating temp.: 10 – 50 ºC / 50 – 122 ºF
Air flow regulation: 2 – 17 SLPM
Vacuum: 30% / 228 mmHg / 9 inHg
Connectors: USB station-PC

Robot RS232
P-005 Pedal
Control Unit Dimension (L x W x H)| 230 x 148 x 160 mm
9.06 x 5.83 x 6.30 in
Total Net Weight:| 3.44 kg / 7.58 lb
Total Package Dimensions/Weight: (L x W x H)| 474 x 368 x 195 mm / 4.41 kg
18.66 x 14.49 x 7.68 in / 9.72 lb

Complies with CE standards.
ESD protected.

Warranty
JBC’s 2-year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labor.
The warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased.
Get 1 extra year of JBC warranty by registering here:https://www.jbctools.com/productregistration/ within 30 days of purchase.

This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility. a manual – color Gris

JBC Logowww.jbctools.com
0027954-0821

Documents / Resources

| JBC TESE-1QA (100V 120V) Precision Hot Air Station [pdf] Instruction Manual
TESE-1QA 100V 120V Precision Hot Air Station, Precision Hot Air Station, Hot Air Station, Air Station, TESE-2QA 230V
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals