Pass/Fail Autofocus Probe

All Lightel video microscopes are designed for eye-safe inspection of fiber optic connector endfaces in order to determine if the endface is contaminated or damaged. The DI-5000 video microscope provides one-touch focusing, a built in flashlight, and output of the camera image to various types of display devices via built-in WiFi or a removable USB connection. It is battery powered and rechargeable via that same USB connection. The CPU within the probe analyzes the condition of the inspected connector endface and the indicator lights will be green if the connector passes and red if it fails. A numbered dial on the probe enables changing the criteria used to analyze the connector condition.

Lightel Technologies, Inc.
2210 Lind Ave. SW, Suite 100 Renton WA 98057 USA
425-277-8000
www.lightel.com

LIGHTEL DI-5000 Digital Fiber Connector Inspector-fig2

Lightel offers more than 120 inspection tips for our DI model probes. Visit our Series 2 Tips webpage for a current list.
http://lightel.com/product/82/series-2-tips

Battery Safety Notice
This product contains a LI-ion battery. Please observe proper precautions when handling or disposing of the battery. CAUTION: Batteries may leak or explode if improperly handled.

  • Use only batteries approved for use with this product.
  • Ensure product is turned off and unplugged before replacing battery.
  • When replacing battery, ensure it is not installed backwards.
  • Do not expose battery to excessive heat or flame.
  • Do no immerse product in water.
  • Transport the battery in the device.
  •  Do not dispose of battery in household waste. This product is designated for separate collection at an appropriate facility.
  • Any replacement battery must be a lithium battery approved by IEC/EN 62133-2, and the approved use environment must meet 50⁰C (or above).

RF Safety Notices

Federal Communications Commission Statement
This device complies with FCC Rules Part 15. Operation is subject to the following two conditions:

  • This device may not cause harmful interference.
  • This device must accept any interference received, including interference that may cause undesired operation.

FCC Caution
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This equipment complies with the FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. To maintain compliance with FCC exposure compliance requirement, please follow operation instruction as documented in this manual.

Canada, Industry Canada (IC) Notices
This device complies with Industry Canada license exempt RSS standard(s). This Class B digital apparatus complies with Canadian ICES-003 and CAN ICES-3(B)/NMB-3(B).
Operation is subject to the following two conditions:

  1. this device may not cause interference, and
  2. this device must accept any interference, including interference that may cause undesired operation of the device. The IC for this device is 25924-DI30005000.

NCC Administrative Regulations on Low Power Radio Waves Radiated Devices:
Without permission granted by the NCC, any company, enterprise, or user is not allowed to change frequency, enhance transmitting power or alter original characteristic as well as performance to a approved low power radio-frequency devices. The low power radio-frequency devices shall not influence aircraft security and interfere legal communications; If found, the user shall cease operating immediately until no interference is achieved. The said legal communications means radio communications is operated in compliance with the Telecommunications Management Act. The low power radio-frequency devices must be susceptible with the interference from legal communications or ISM radio wave radiated devices.

Product Layout

  Product Setup

(Suggested software is for testing purposes only. Final Lightel software will be able to view both the WiFi signal and the USB signal.)

Product Use

  • WIFI:
    Once setup is complete, press the Power Button (Figure 3) on the rear of the DI-5000 until the Power Light turns on (green color). Then turn on the WiFi by pressing the WiFi button. The WiFi light will blink white. Once WiFi on the DI-5000 has been turned on, check the WiFi connections on your PC or other device for the WiFi signal “LT-DI-5000…” When you select the correct signal the blinking white light will light continuously and once your device has completed the connection the DI-5000 will be ready to use.

  • USB:
    Once setup is complete, insert the mini B cable into the port at the rear of the DI-5000. Attach the other end of the cable to a full USB port on a PC or other approved device. The Power Light will blink if the battery whenever the battery is charging. To use the USB for data output, please make sure the WiFi is turned off.

  • Both:

    • The battery can be recharged while using WiFi by inserting a mini B cable into the port at the rear of the DI-5000 and attaching the cable to a USB charging port. The Power Light will begin to blink when the battery charge falls below 25% and will continue to blink while the battery is charging. When fully charged, blinking will stop.
    • If you have not already done so, attach the appropriate tip for the connector you will be inspecting (see the next page for information on attaching and using Series 2 inspection tips).
    • For male connectors, you will insert the ferrule into the tip. For female connectors, the tip is inserted into the adapter. When properly inserted, a stop position in the tip ensures that the connector is within the focal range.
    • When ready, press and release the Autofocus Button. The lens will move to determine the focal point. When it is properly focused the Focus Status Light will again turn green. (If it remains red, you can try the Autofocus Button again, or use the Manual Focus Knob to refocus.) The Capture Button will send an electronic signal to your attached viewing device. Depending on the attached hardware and your settings, the Capture Button will freeze the image, capture the image, or analyze the image.
      The Flashlight Button turns the Flashlight on or off when additional external illumination is needed. The light has no effect on the illumination provided when viewing the connector ferrule.

  Attaching and Removing Inspection Tips

  • All DI-5000 tips are held in place with a locknut. All tips have a slot (some specialty tips have more than one slot) which will match up with the key at the top of the DI-5000 to ensure that the tip is properly aligned.

  • To attach a tip, hold the probe with the tip facing away from you and turn the locknut clockwise.

  • To remove a tip, hold the probe with the tip facing away from you and turn the locknut counterclockwise.

  Battery Replacement

  • Remove Battery Door
    Use a Phillips screwdriver to remove the two black Phillips screws, then open the battery door.

  • Remove Battery

  • Replace Battery
    Replace battery with the positive end facing the rear of the probe.

  • Replace Cover and Screws
    Close the battery door and reattach the two black Phillips screws to complete the process.

Specifications

Field of view ~ 640µm x 480µm
Detectable resolution 0.5μm
Focus Autofocus or manual adjustment, 2mm max travel
Autofocus time ~2 seconds
Camera 1/4” CMOS
Light source Blue LED
Power supply Rechargeable Li-ion battery or USB2.0 (or higher) port
Battery Single-cell, Li-ion, Panasonic NCR 18650
Power rating 5V __ 2A
Battery life >7 hours, continuous use
Dimensions 205mm x 37mm x 49mm (Probe with cap)
Weight 191g (including battery)
Operating temperature 0°C to 50°C (0°C to 45°C when charging)1
Storage temperature -20°C to 50°C
Frequency 2412-2462 MHz
Supported operating systems (ConnectorView Software) Windows 7®, Windows 8®,

Windows 10® 32-bit and 64-bit processors

Warranty

Lightel Technologies Inc. products are shipped after passing a final inspection by Lightel’s Quality Assurance program. In the event of
a product failure please contact the Lightel Sales Department at (425)277-8000 or email sales@lightel.com
The warranty period is for one year after the date of delivery. Should failure occur within that period, repair or replacement will be made, as necessary, free of charge. The Warranty will not be honored if:

  1. Failure is caused by usage non-conforming to the instruction manual or negligent operation.
  2. Failure is caused by an unauthorized electric or mechanical modification by the customer.
    The extent of the warranty shall be limited to repair or replacement of the defective unit.

About Lightel
LIGHTEL designs, develops, and manufactures a broad range of fiber optics products and services for telecommunications, CATV, and datacom industries. Our product line includes fused, micro-optic and planar lightwave circuit- based passive optical components (such as splitters, couplers, isolators, circulators, CWDMs, CCWDMs, DWDMs). In addition, we offer our technology leading connector end face video microscope products including the Connector Inspector, Digital Inspector and ViewConn. We also manufacture fiber optic component workstations for those customers who wish to fabricate their own devices for vertical integration, product development or R&D purposes.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals