SYMBOLS
| READ AND UNDERSTAND ALL SAFETY INFORMATION BEFORE USING THIS PRODUCT.
Failure to follow these safety instructions may result in ELECTRICAL SHOCK,
EXPLOSION, FIRE, which may result in a SERIOUS INJURY, DEATH, or PROPERTY
DAMAGE.
---|---
| Electrical Shock. Product is an electrical device that can shock and
cause serious injury. Do not cut power cords. Do not submerge in water or get
wet.
| Explosion. Unmonitored, incompatible, or damaged batteries can explode
if used with product. Do not leave product unattended while in use. Do not
attempt to jump start a damaged or frozen battery. Use product only with
batteries of recommended voltage. Operate product in well ventilated areas.
| Fire. Product is an electrical device that emits heat and is capable of
causing burns. Do not cover product. Do not smoke or use any source of
electrical spark or fire when operating product. Keep product away from
combustible materials.
| Eye Injury. Wear eye protection when operating product. Batteries can
explode and cause flying debris. Battery acid can cause eye and skin
irritation. In the case of contamination of eyes or skin, flush affected area
with running clean water and contact poison control immediately.
| Explosive Gases. Working in the vicinity of a lead-acid is dangerous.
Batteries generate explosive gases during normal battery operation. To reduce
risk of battery explosion, follow all safety information instructions and
those published by the battery manufacturer and manufacturer of any equipment
intended to be used in the vicinity of battery. Review cautionary markings on
these products and on engine.
Important Safety Warnings
About GENIUS10
The NOCO GENIUS10 represents some of the most innovative and advanced technology on the market, making each charge simple and easy. It is quite possibly the safest and most efficient charger you will ever use. The GENIUS10 is designed for charging all types of 6V & 12V lead-acid batteries, including Lithium (LiFePO4), Wet (Flooded), Gel, MF (Maintenance-Free), CA (Calcium), EFB (Enhanced Flooded Battery), and AGM (Absorption Glass Mat) batteries. It is suitable for charging battery capacities up to 230 Amp-Hours and maintaining all battery sizes.
Getting Started
Before using the charger, carefully read the battery manufacturer’s specific precautions and recommended rates of charge for the battery. Make sure to determine the voltage and chemistry of the battery by referring to your battery owner’s manual prior to charging.
Mounting
It is important to keep in mind the distance to the battery. The DC cable length from the charger, with either the battery clamp or eyelet terminal connectors, is approximately 77.7 inches (1973.6mm). Allow for 12-inches (304mm) of slack between connections.
Proposition 65
Battery posts, terminals, and related accessories contain chemicals, including lead. These materials are known to the State of California to cause cancer and birth defects and other reproductive harm.
Personal Precaution
Only use product as intended. Someone should be within range of your voice or close enough to come to your aid in case of emergency. Have a supply of clean water and soap nearby in the case of battery acid contamination. Wear complete eye protection and protective clothing while working near a battery. Always wash hands after handling batteries and related materials. Do not handle or wear any metal objects when working with batteries including; tools, watches or jewelry. If metal is dropped onto battery, it may spark or create a short circuit resulting in electrical shock, fire, explosion which may result in injury, death or property damage.
Minors
If the product is intended by “Purchaser” to be used by a minor, purchasing adult agrees to provide detailed instructions and warnings to any minor prior to use. Failure to do so is the sole responsibility of the “Purchaser,” who agrees to indemnify NOCO for any unintended use or misuse by a minor.
Choking Hazard
Accessories may present a choking hazard to children. Do not leave children unattended with product or any accessory. The product is not a toy.
Handling
Handle product with care. The product can become damaged if impacted. Do not use a damaged product, including, but not limited to, cracks to the casing or damaged cables. Do not use product with a damaged power cord. Humidity and liquids may damage product. Do not handle product or any electrical components near any liquid. Store and operate product in dry locations. Do not operate product if it becomes wet. If product is already operating and becomes wet, disconnect it from the battery and discontinue use immediately. Do not disconnect the product by pulling on the cables.
Modifications
Do not attempt to alter, modify or repair any part of the product. Disassembling product may cause injury, death or damage to property. If product becomes damaged, malfunctions or comes in contact with any liquid, discontinue use, and contact NOCO. Any modifications to the product will void your warranty.
Accessories
This product is only approved for use with NOCO accessories. NOCO is not responsible for user safety or damage when using accessories not approved by NOCO.
Location
Prevent battery acid from coming in contact with the product. Do not operate the product in a closed-in area or an area with restricted ventilation. Do not set a battery on top of product. Position cable leads to avoid accidental damage by moving vehicle parts (including hoods and doors), moving engine parts (including fan blades, belts, and pulleys), or what could become a hazard that may cause injury or death.
Operating Temperature
This product is designed to work in ambient temperatures between -4° F and 104° F (-20° C and 40° C). Do not operate outside of temperature ranges. Do not charge a frozen battery. Discontinue use of product immediately if the battery becomes excessively warm.
Storage
Do not use or store your product in areas with high concentrations of dust or airborne materials. Store your product on flat; secure surfaces so it’s not prone to falling. Store your product in a dry location. The storage temperature is -20ºC – 25ºC (average temperature). Never exceed 80ºC under any condition.
Compatibility
The product is only compatible with 6V & 12-volt Lead-Acid, AGM, and Lithium batteries. Do not attempt to use product with any other type of battery. Charging other battery chemistries may result in injury, death or property damage. Contact the battery manufacturer prior to attempting to charge the battery. Do not charge a battery if you are unsure of the battery’s specific chemistry or voltage.
Medical Devices
Product may emit electromagnetic fields. Product contains magnetic components which may interfere with pacemakers, defibrillators, or other medical devises. These electromagnetic fields may interfere with pacemakers or other medical devices. Consult with your physician prior to use if you have any medical device including pacemakers. If you suspect the product is interfering with a medical device, stop using the product immediately and consult your physician.
Cleaning
Power off the product before attempting any maintenance or cleaning. Clean and dry product immediately if it comes in contact with liquid or any type of contaminant. Use a soft, lint-free (micro fiber) cloth. Avoid getting moisture in openings.
Explosive Atmospheres
Obey all signs and instructions. Do not operate product in any area with a potentially explosive atmosphere, including fueling areas or areas which contain chemicals or particles such as grain, dust or metal powders.
High-Consequence Activities
This product is not intended for use where the failure of the product could lead to injury, death or severe environmental damage.
Radio Frequency Interference
Product is designed, tested, and manufactured to comply with regulations governing radio frequency emissions. Such emissions from the product can negatively affect the operation of other electronic equipment, causing them to malfunction.
Model Number: GENIUS10
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
How To Use
Charging Modes
The GENIUS10 has nine (9) modes: Standby, 12V, 12V AGM, 12V LITHIUM, 6V, 6V AGM, REPAIR, SUPPLY and Force. Some charge modes must be pressed and held for three (3) to five (5) seconds to enter the mode. These “Press and Hold” modes are advanced charging modes that require your full attention before selecting. It is important to understand the differences and purpose of each charge mode. Do not operate the charger until you confirm the appropriate charge mode for your battery. Below is a brief description:
Mode| Explanation| (Peak Voltage Measured At 25°C, Amperage Rating
Is Bulk Amperage When Above 0°C)
---|---|---
Standby| In Standby mode, the charger is not charging or providing any power
to the battery. Energy Save is activated during this mode, drawing microscopic
power from the electrical outlet. Canbus is enabled in Standby mode. When in
Standby, the orange Standby LED will illuminate.
No Power
12V| For charging 12-volt Wet Cell, Gel Cell, Enhanced Flooded, Maintenance-
Free and Calcium batteries. When selected, the 12V white LED will illuminate.
14.5V | 10A | Up To 230AH Batteries
12V AGM| For charging 12-volt AGM batteries. When selected, the 12V AGM white
LED will illuminate.
14.8V | 10A | Up To 230AH Batteries
12V LITHIUM| For charging 12-volt lithium-ion batteries, including lithium
iron phosphate. When selected, the 12V Lithium blue LED will illuminate. For
use on batteries with Battery Management Systems (BMS) only.
14.6V | 10A | Up To 230AH Batteries
Press & Hold (3 Seconds)| For charging 6-volt Wet Cell, Gel Cell, Enhanced
Flooded, Maintenance-Free and Calcium batteries. When selected, the 6V white
LED will illuminate.
7.25V | 10A | Up To 230AH Batteries
Press & Hold (3 Seconds)| For charging 6-volt advanced AGM batteries, which
requires a higher than normal charging voltage. When selected, a white LED
will illuminate.
7.40V | 10A | Up To 230AH Batteries
Force Mode Press & Hold (5 Seconds)| For charging batteries with a voltage
lower than 1V. Press and Hold for five (5) seconds to enter Force Mode. The
selected charge mode will then operate under Force Mode for five (5) minutes
before returning to standard charging in the selected mode.
10A | Up To 230AH Batteries
12V SUPPLY| Converts to a DC power supply for powering any 12VDC device, like
a tire inflator, oil changer, or as a memory retainer when replacing a
battery. When selected, a red LED will illuminate.
13.6V @ 25°C | 10A | Max 12A
[Press and Hold 3 Seconds With Clamps Not Connected]
12V REPAIR| An advanced battery recovery mode for repairing and restoring,
old, idle, damaged, stratified or sulfated batteries. When selected, a red LED
will illuminate and flash.
Current conditioning up to 16.5V.
[From Standby Press and Hold 3 Seconds With Clamps Connected to the
Battery]
Using 6V. [Press & Hold for 3 seconds]
6V charge mode is designed for 6-volt lead-acid batteries only, like Wet Cell,
Gel Cell, Enhanced Flooded, Maintenance-Free and Calcium batteries. Press and
hold for three (3) seconds to enter 6V Charge Mode. Consult the battery
manufacturer before using this mode.
Using 12V Lithium.
12V Lithium charge mode is designed for 12-volt lithium-ion batteries only,
including lithium iron phosphate
CAUTION. USE THIS MODE WITH EXTREME CARE. THIS MODE SHOULD ONLY BE USED WITH 12-VOLT LITHIUM BATTERIES THAT HAVE A BUILT-IN BATTERY MANAGEMENT SYSTEM (BMS). LITHIUM-ION BATTERIES ARE MADE AND CONSTRUCTED IN DIFFERENT WAYS AND SOME MAY OR MAY NOT CONTAIN A BATTERY MANAGEMENT SYSTEM (BMS). CONSULT THE LITHIUM BATTERY MANUFACTURER BEFORE CHARGING AND ASK FOR RECOMMENDED CHARGING RATES ANDVOLTAGES. SOME LITHIUM-ION BATTERIES MAY BE UNSTABLE AND UNSUITABLE FOR CHARGING.
Using 13.6V Supply. [Press and Hold 3 Seconds With Clamps Not Connected]
13.6V Supply converts the charger to a constant current, constant voltage DC
power supply. It can be used to power 12VDC devices, tire inflators, seat
heaters and more. As a power supply, it can also be used to retain a vehicle’s
on-board computer settings during battery repair or replacement. 13.6V Supply
provides 13.6-volts at 10A with overload protection at 12A (Max).
CAUTION. USE THIS MODE WITH EXTREME CARE. SUPPLY MODE DISABLES SAFETY FEATURES AND LIVE POWER IS PRESENT AT THE CONNECTORS. DO NOT TOUCH CONNECTIONS TOGETHER. RISK OF SPARKS, FIRE, EXPLOSION, PROPERTY DAMAGE, INJURY, AND DEATH
Using 12V Repair. [From Standby Press and Hold 3 Seconds With Clamps Connected to the Battery] 12V Repair is an advanced battery recovery mode for repairing and storing, old, idle, damaged, stratified or sulfated batteries. Not all batteries can be recovered. Batteries tend to become damaged if kept at a low charge and/or never given the opportunity to receive a full charge. The most common battery problems are battery sulfation and stratification. Both battery sulfation and stratification will artificially raise the open circuit voltage of the battery, causing the battery to appear fully charged, while providing low capacity. Use 12V Repair in attempt to reverse these problems. For optimal results, take the 12-volt battery through a full charge cycle, bringing the battery to full charge, before using this mode. The level of sulfation found in the battery will determine the voltage driven into the battery (up to 16.5V). 12V Repair can take up to four (4) hours to complete the recovery process and will return to Standby when completed
CAUTION. USE THIS MODE WITH CARE. THIS MODE IS FOR 12-VOLT LEAD-ACID BATTERIES ONLY. THIS MODE COULD RESULT IN HIGH CHARGING VOLTAGE AND MAY CAUSE SOME WATER LOSS IN WET (FLOODED) CELL BATTERIES. BE ADVISED, SOME BATTERIES AND ELECTRONICS MAY BE SENSITIVE TO HIGH CHARGING VOLTAGES. TO MINIMIZE RISKS TO ELECTRONICS, DISCONNECT THE BATTERY BEFORE USING THIS MODE.
Force Mode. [Press & Hold for 5 seconds]
Force mode allow the charger to manually begin charging when the connected
battery’s voltage is too low to be detected. If battery voltage is too low for
the charger to detect, press and hold the mode button for 5 seconds to
activate Force Mode, then select the appropriate mode. All available modes
will flash. Once a charge mode is selected, the Charge Mode LED and Charge LED
will alternate between each other, indicating Force Mode is active. After five
(5) minutes the charger will return to the normal charge operation and low
voltage detection will be reactivated
CAUTION. USE THIS MODE WITH EXTREME CARE. FORCE MODE DISABLES SAFETY FEATURES AND LIVE POWER IS PRESENT AT THE CONNECTORS. ENSURE ALL CONNECTIONS ARE MADE PRIOR TO ENTERING FORCE MODE, AND DO NOT TOUCH CONNECTIONS TOGETHER. RISK OF SPARKS, FIRE, EXPLOSION, PROPERTY DAMAGE, INJURY, AND DEATH.
Connecting to the Battery.
Do not connect the AC power plug until all other connections are made.
Identify the correct polarity of the battery terminals on the battery. Do not
make any connections to the carburetor, fuel lines, or thin, sheet metal
parts. The below instructions are for a negative ground system (most common).
If your vehicle is a positive ground system (very uncommon), follow the below
instructions in reverse order.
- Connect the positive (red) eyelet terminal connector to the positive (POS,P,+) battery terminal.
- Connect the negative (black) eyelet terminal connector to the negative (NEG,N,-) battery terminal.
- Connect the battery charger into a suitable electrical outlet. Do not face the battery when making this connection.
- When disconnecting, disconnect in the reverse sequence, removing the negative first (or positive first for positive ground systems).
Begin Charging.
- Verify the voltage and chemistry of the battery.
- Confirm that you have connected the battery clamps or eyelet terminal connectors properly and the AC power plug is plugged into an electrical outlet.
- [First time use]The charger will begin in Standby mode, indicated by an orange LED. In Standby, the charger is not providing any power.
- Press the mode button to toggle to the appropriate charge mode (press and hold for three seconds to enter an advanced charge mode) for the voltage andchemistry of your battery.
- The mode LED will illuminate the selected charge mode and the Charge LEDs will illuminate (depending on the health of the battery) indicating the charging process has started.
- The charger can now be left connected to the battery at all times to provide maintenance charging.
Auto-Memory: The charger has built in auto-memory and will return to the last charge mode when connected. To change modes after the first use, press the mode button.
Charging Times
Charging Times.
The estimated time to charge a battery is shown below. The size of the battery
(Ah) and its depth of discharge (DOD) greatly affect its charging time. The
charge time is based on an average depth of discharge to a fully charged
battery and is for reference purposes only. Actual data may differ due to
battery conditions. The time to charge a normally discharged battery is based
on a 50% DOD. Temperature will also impact charging times. The GENIUS10
features thermal compensation that automatically adjusts charging profiles to
maximize charging performance.
Battery Size | Approximate Time to Charge In Hours |
---|---|
Ah (Amp hour) | 6V |
20 | 1.5 |
40 | 3.0 |
80 | 6.0 |
100 | 7.0 |
230 | 17.3 |
Understanding Charge LEDs
LED | Explanation |
---|---|
25% Red LED | The 25% Charge LED will slowly pulse “on” and |
“off”, when the battery is less than 25% fully charged. When the battery is
25% charged, the red Charge LED will be solid.
50% Red LED | The 50% Charge LED will slowly pulse “on” and
“off”, when the battery is less than 50% fully charged. When the battery is
50% charged, the red Charge LED will be solid.
75% Orange LED | The 75% Charge LED will slowly pulse “on” and “off”,
when the battery is less than 75% fully charged. When the battery is 75%
charged, the orange Charge LED will be solid.
100% Green LED | Pulsing Green LED – Bulk charge complete, optimizing
battery for extended life.
Solid Green LED – When the battery is 100% charged, the Charge LED will be solid green.
Maintenance Green LE | After the battery is fully charged, the charger will continue monitoring the battery, and provide ongoing maintenance and optimization. The 100% Charge LED will pulse “on” and “off” slowly during these cycles. The charger can be left connected to the battery indefinitely.
Understanding Error LEDs
Error Conditions will be indicated by the following LEDs
LED | Reason/Solution |
---|---|
Solid | Charger is in Standby mode or Battery voltage is too low for charger |
to detect.
Solid| Battery voltage is too high for the selected charge mode. Check the
battery and charge mode.
Solid| Possible battery short / Battery will not hold a charge. Have battery
checked by a professional.
Solid| Reverse polarity. Reverse the battery connections.
Flashing| Charger internal temperature too high / Charger will resume function
once the Charger internal temperature drops.
Charger ambient temperature too cold / Charger will resume function once the
Charger ambient temperature rises.
- Mode Button Push to cycle through charging Modes.
- Overvoltage Error LED Illuminates solid Red; Battery Voltage is above Protect voltage.
- Bad Battery Error LED Illuminates solid Red when connected battery will not hold a charge.
- Reverse Polarity Error LED Illuminates solid Red when reverse polarity is detected.
- Standby LED Illuminates when the charger is in Standby Mode, the charger is not charging or providing any power to the battery
- Charge LED indicates the connected battery(s) state-of-charge.
- Mode LED Indicates the Charge Mode the charger is currently in. Push the MODE button to cycle through charge Modes.
- «Press and Hold» Mode LED Mode button must be pressed and held for 3 seconds to enter the mode.
- Supply Mode LED Illuminates solid Red when Supply mode is selected.
- Repair Mode LED When selected, a red LED will illuminate and flash.
Technical Specifications
Input Voltage AC: | 120-240 VAC, 50-60Hz |
---|---|
Working Voltage AC: | 120-240 VAC, 50-60Hz |
Output Power: | 150 W Max |
Charging Voltage: | Various |
Charging Current: | 10A (12V), 10A (6V)) |
Low-Voltage Detection: | 1V (12V), 1V (6V) |
Back Current Drain | <0.5mA |
Ambient Temperature: | -20°C to +40°C |
Type of Batteries: | 6V, 12V |
Battery Chemistries: | Wet, Gel, MF, CA, EFB, AGM, Calcium, Lithium |
Battery Capacity: | Up to 230Ah, Maintains All Battery Sizes |
Housing Protection: | IP65 |
Cooling: | Natural Convection |
Dimensions (L x W x H): | 7.1 x 3.6 x 2.3 Inches |
Weight: | 3.43 Pounds |
3 Year Hassle-Free Warranty
NOCO warrants that this product (the “Product”) will be free from defects in material and workmanship for a period of Three (3) years from the date of purchase (the “Warranty Period”). For defects reported during the Warranty Period, NOCO will, at its discretion, and subject to NOCO’s technical support analysis, either repair or replace defective products. Replacement parts and products will be new or serviceably used, comparable infunction and performance to the original part and warranted for the remainder of the original Warranty Period.
NOCO’S LIABILITY HEREUNDER IS EXPRESSLY LIMITED TO REPLACEMENT OR REPAIR. TO THE MAXIMUM EXTENT PERMITTED BY LAW, NOCO SHALL NOT BE LIABLE TO ANY PURCHASER OF THE PRODUCT OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, CONSEQUENTIAL OR EXEMPLARY DAMAGES, INCLUDING, BUT NOT LIMITED
TO, LOST PROFITS, PROPERTY DAMAGE OR PERSONAL INJURY, RELATED IN ANY WAY TO THE PRODUCT, HOWSOEVER CAUSED, EVEN IF NOCO HAD KNOWLEDGE OF THE POSSIBILITY OF SUCH DAMAGES. THE WARRANTIES SET FORTH HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS, IMPLIED, STATUTORY OR OTHERWISE, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND THOSE ARISING FROM COURSE OF DEALING, USAGE OR TRADE PRACTICE. IN THE EVENT THAT ANY APPLICABLE LAWS IMPOSE WARRANTIES, CONDITIONS OR OBLIGATIONS THAT CANNOT BE EXCLUDED OR MODIFIED, THIS PARAGRAPH SHALL APPLY TO THE GREATEST EXTENT ALLOWED BY SUCH LAWS.
This Warranty is made solely for the benefit of the original purchaser of the Product from NOCO or from a NOCO approved reseller or distributor and is not assignable or transferable. To assert a warranty claim, the purchaser must: (1) request and obtain a return merchandise authorization (“RMA”) number and return location information (the “Return Location”) from NOCO Support by emailing support@no.co or by calling 1.800.456.6626; and (2) send the Product, including RMA number, and receipt to the Return Location. DO NOT SEND IN PRODUCT WITHOUT FIRST OBTAINING AN RMA FROM NOCO SUPPORT
The original purchaser is responsible (and must prepay) all packaging and transportation costs to ship products for warranty service.
NOTWITHSTANDING THE ABOVE, THIS HASSLE-FREE WARRANTY IS VOID AND DOES NOT APPLY TO PRODUCTS THAT: (a) are misused, mishandled,subjected to abuse or careless handling, accident, improperly stored, or operated under conditions of extreme voltage, temperature, shock, or vibration beyond NOCO’s recommendations for safe and effective use; (b) improperly installed, operated or maintained; (c) are/were modified without the express written consent of NOCO; (d) have been disassembled, altered or repaired by anyone other than NOCO; (e) the defects of which were reported after the Warranty Period.
THIS HASSLE-FREE WARRANTY DOES NOT COVER: (1) normal wear and tear; (2) cosmetic damage that does not affect functionality; or (3) Products where the NOCO serial number is missing, altered, or defaced.
HASSLE-FREE WARRANTY CONDITIONS
These conditions apply only to Product during the Warranty Period. The Hassle-
Free Warranty is void either by elapsed time from date of purchase (elapsed
time from serial number date, if no proof of purchase) or from the conditions
listed earlier in this document. Return Product with the appropriate
documentation.
With Receipt:
0-3 Years: NO Charge. With proof of purchase, The warranty period begins on
date of purchase
With NO Receipt:
0-3 Years: NO Charge. With NO proof of purchase, The warranty period begins on
the serial number date
We recommend registering your NOCO product in order to upload proof of purchase and extend your effective warranty dates. You may register your NOCO product online at: no.co/register. If you have any questions regarding your warranty or product, contact NOCO Support (email and phone number above) or write to: The NOCO Company, at 30339 Diamond Parkway,
102, Glenwillow, OH 44139 USA.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>