RUPERT NEVE DESIGNS 5057 Orbit 16×2 Summing Mixer User Manual
- June 5, 2024
- Rupert Neve Designs
Table of Contents
- RUPERT NEVE DESIGNS 5057 Orbit 16×2 Summing Mixer
- Important Safety Instructions
- Rupert Neve Designs 5057 ORBIT: 16 x 2 Summing Mixer
- 5057 Front Panel
- 5057 Rear-Panel
- 5057 Front-Panel Features
- 5057 Rear-Panel Features
- 5057 Specifications
- 5057 Frequency Response
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
RUPERT NEVE DESIGNS 5057 Orbit 16×2 Summing Mixer
Important Safety Instructions
-
Read these instructions.
-
Keep these instructions.
-
Heed all warnings.
-
Follow all instructions.
-
Do not use this apparatus near water.
-
Clean only with a dry cloth.
-
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
-
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
-
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for the replacement of the obsolete outlet.
-
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
-
Only use attachments/accessories specified by the manufacturer.
-
Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
-
Unplug this apparatus during lightning storms or when unused for long periods of time.
-
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
-
This apparatus shall not be exposed to dripping or splashing, and no object filled with liquids, such as vases or beer glasses, shall be placed on the apparatus.
-
Do not overload wall outlets and extension cords as this can result in a risk of fire or electric shock.
-
This apparatus has been designed with Class-I construction and must be connected to a mains socket outlet with a protective earthing connection (the third grounding prong).
-
This apparatus has been equipped with a rocker-style AC main power switch. This switch is located on the rear panel and should remain readily accessible to the user.
-
The MAINS plug or an appliance coupler is used as the disconnect device, so the disconnect device shall remain readily operable.
CAUTION AVIS: RISK OF ELECTRIC SHOCK. DO NOT OPEN RISQUE DE CHOC ELECTRIQUE. NE PAS OUVRIR
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL
ATTENTION: POUR EVITER LES RISQUES DE CHOC ELECTRIQUE, NE PAS ENLEVER LE COUVERCLE. AUCUN ENTRETIEN DE PIECES INTERIEURES PAR L’USAGER.
The lightning flash with an arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure, that may be of sufficient magnitude to constitute a risk of electric shock to persons. -
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
CAUTION: Changes or modifications to this device not expressly approved by Rupert Neve Designs LLC, could void the user’s authority to operate the equipment under FCC rules.
-
This apparatus does not exceed the Class A/Class B (whichever is applicable) limits for radio noise emissions from digital apparatus as set out in the radio interference regulations of the Canadian Depar tment of Communications.
-
Exposure to extremely high noise levels may cause permanent hearing loss. Individuals vary considerably in susceptibility to noise-induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a period of time. The U.S. Government’s Occupational Safety and Health Administration (OSHA) has specified the permissible noise level exposures shown in the following chart. According to OSHA, any exposure in excess of these permissible limits could result in some hearing loss. To ensure against potentially dangerous exposure to high sound pressure levels, it is recommended that all persons exposed to equipment capable of producing high sound pressure levels use hearing protectors while the equipment is in operation. Ear plugs or protectors in the ear canals or over the ears must be worn when operating the equipment in order to prevent permanent hearing loss if exposure is in excess of the limits set forth here:
Duration, per day in hours| Sound Level dBA, Slow
Response
| Typical Example
---|---|---
8| 90| Duo in small club
6| 92|
4| 95| Subway Train
3| 97|
2| 100| Typical music via head phones
1.5| 102|
1| 105| Siren at 10 m distance
0.5| 110|
0.25 or less| 115| Loudest parts at a rock concert
WARNING — To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
Rupert Neve Designs 5057 ORBIT: 16 x 2 Summing Mixer
Thank you for purchasing the Rupert Neve Designs 5057 ORBIT. We hope you enjoy using this product as much as we have enjoyed designing and building it. The 5057 features Class-A analog signal paths, custom Rupert Neve Designs transformer-coupled outputs, and a high-accuracy stepped attenuator for mix output level control.
5057 Front Panel
5057 Rear-Panel
5057 Front-Panel Features
Mono
These four push-button switches allow the user to input mono signals for equal
summing to the left and right mix buss outputs. Each individual channel gets
summed to mono at unity gain from input to output (0dBu In = 0dBu Out). There
is no pan law associated with this feature. If an input signal is connected to
Channel 1 or Channel 2, and the MONO 1/2 button is depressed, that signal will
be equally summed to the left and right mix buss outputs. If two identical
input signals are connected to Channels 1 and 2, the output will be +6dB due
to standard voltage summing laws.
Silk
The SILK illuminated push-button switch allows the user to toggle between OFF,
RED and BLUE SILK transformer modes. Red SILK has adds high-frequency emphasis
to the transformer harmonic content. Blue SILK adds low-frequency em-phasis to
the transformer harmonic content.
Texture
This 31-detent potentiometer allows the user to control the amount of harmonic
saturation added to Main Out and -6dB Out signal path. The texture
potentiometer is only functional when Red or Blue SILK modes are engaged.
Signal Present / Overload (Left and Right)
The Signal Present / Overload LEDs illuminate green to show Signal Present
conditions (-20dBu) and subsequently illuminate Red to indicate Overload
conditions (+24dBu). The Overload LED illuminates when the signal is 2dB below
clip point in order to warn the user that the signal peaks are close to actual
clip point so that the user can adjust accordingly.
Trim
This 12-position rotary switch allows the user to accurately adjust the
desired attenuation level for the mix output. The TRIM control is accurate to
within +/- 0.1dB of the labeled attenuation steps on the front panel control.
(see pg. 2)
Power
The front-panel POWER LED illuminates GREEN to provide the user with power
status of the 5057.
5057 Rear-Panel Features
Power
An IEC 3-Pin grounded AC inlet with power switch is provided on the back of
the 5057. The 5057 can accept an input range of 100-240VAC, and draws a
maximum of 35 Watts. There are no user-accessible fuses, they are integrated
within the internal power supplies.
GND Lift
This slide switch lifts XLR Output Pin 1 from chassis ground. This switch
enables the user to more effectively eliminate ground loops if they are
present.
-6dB Out
This output is fed from the custom Rupert Neve Designs tapped transformer
output. This lower level output allows the user to drive the transformer
harder, achieving more harmonic saturation, without having to worry about
clipping the inputs of their DAW or other successive pieces of gear. The -6dB
Output and the Main Output can be connected simultaneously to feed two
different destinations.
5057 Rear-Panel Features
Main Out
The Main Output features a custom Rupert Neve Designs transformer and is
capable of a maximum output level of +26dBu. The transformer outputs on the
5057 maintain excellent signal-to-noise performance, wide bandwidth and are
driven by a fully Class-A signal path.
Link
The Link TRS jacks on the 5057 rear-panel allow the user to link multiple 5057
summing mixers for expansion of sum-ming channel count. The Link input and
output jacks are solely intended to be used to connect other 5057 summing
mixers. DO NOT use these jacks for any other purpose.
Note: Each TRS link jack (IN and OUT) connects to the Left (Tip) and
Right (Ring) UNBALANCED mix buss paths. It is therefore important to ONLY use
a TRS cable to connect 5057 units.
Input Channels 1-8
The first group of eight balanced Class-A input channels are made available on
this rear-panel female DB25.
Input Channels 9-16
The second group of eight balanced Class-A input channels are made available
on this rear-panel female DB25.
5057 Specifications
- Input Impedance: 16 kΩ
- Frequency Response: Z SOURCE = 40Ω Balanced, 30 ft. XLR Output Cable, 200k T
- 10 Hz to 50 kHz: +/- 0.1dB typical
- 150 kHz: -3dB typical
- Noise (BW 22 Hz – 22 kHz, Un-terminated): -90 dBu typical
- Maximum Input Level @ 1 kHz: + 26dBu typical
- Maximum Output Level @ 1 kHz: 26dBu typical
- THD+N%: BW 22 Hz – 22 kHz, Balanced Input to Main Out
- 0 dBu @ 1kHz: 0.003% typical
- +20 dBu @ 1kHz: 0.0006% typical
- Crosstalk: BW 22 Hz – 22 kHz, Balanced Input to Main Output
- 1 kHz: – 103 dBu typical
- 10 kHz: 93 dBu typical
- Product Dimensions (W x D x H): 19” (48.3 cm) x 9” (22.9 cm) x 1.75” (4.4 cm)
- Shipping Dimensions (L x W x H): 24” (61 cm) x 13” (33 cm) x 4” (10.2 cm)
- Shipping Weight: 10 lbs (4.5 kg)
5057 Frequency Response
PRODUCT WARRANTY
Rupert Neve Designs warrants this product to be free from defects in materials
and workmanship for a period of three (3) years from date of purchase, and
agrees to remedy any defect identified within such three year period by, at
our option, repairing or replacing the product.
LIMITATIONS AND EXCLUSIONS
This warranty, and any other express or implied warranty, does not apply to
any product which has been improperly installed, subjected to usage for which
the product was not designed, misused or abused, damaged during shipping,
damaged by any dry cell battery, or which has been altered or modified in any
way. This warranty is extended to the original end-user purchaser only. A
purchase receipt or other satisfactory proof of date of original purchase is
required before any warranty service will be performed. THIS EXPRESS, LIMITED
WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, TO THE EXTEND
ALLOWED UNDER APPLICABLE STATE LAW. IN NO EVENT SHALL RUPERT NEVE DESIGNS BE
LIABLE FOR ANY SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES RESULTING FROM
THE USE OF THIS PRODUCT. Some states do not allow the exclusion or limitation
of consequential damages or limitations on how long an implied warranty lasts,
so this exclusion may not apply to you.
WARRANTY SERVICE
If you suspect a defect in this product, please call us at
512-847-3013 or contact our support
staff (service@rupertneve. com) for
troubleshooting. If it is determined that the device is malfunctioning, we
will issue a Return Material Authorization and provide instructions for
shipping the device to our service department.
Rupert Neve Designs
PO Box 1969
Wimberley TX 78676
www.rupertneve.com
tel: +1 512-847-3013
fax: +1 512-847-8869
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>