RENPHO RF-EM001R Eye massager with remote User Manual
- June 5, 2024
- Renpho
Table of Contents
- RENPHO RF-EM001R Eye massager with remote
- Product structure
- Technical parameters
- What’s included
- Wearing the device
- During operation
- Charging
- Volume adjustment
- FAQ and troubleshooting
- Cleaning and maintenance
- Guarantee
- Declaration of Conformity
- FCC STATEMENT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
RENPHO RF-EM001R Eye massager with remote
Attention
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without Supervision. Please read and comprehend
all the contents of this manual and operate the product according to the
instructions.
- DO NOT use if you have had an eye operation, or if you have any eye diseases such as glaucoma, cataract, and amotio retinae.
- DO NOT clean the product with water; clean it with cotton soaked in alcohol
- This product has a hot surface; people sensitive to heat should take extra care when using this.
- Juveniles, disabled people, and the elderly should only use this product when properly supervised.
- The product is intended for personal use; it is not intended to replace medical care and medical devices.
- DO NOT use if you have any swlling in the eye area.
- DO NOT disassemble the product, DO NOT impact or squeeze its interior lithium battery or expose it to fire;
- DO NOT use if the battery has been immersed in water
- DO NOT use in high temperatures or humid environments. Avoid direct exposure to the sun.
- Consult your doctor if you have sensitive skin, allergic dermatitis, or orthopedic bio materials.
- Remove contact lenses, hairpins, and hair accessories before using.
- Start the eye massager after putting it on in order to avoid damage to the air bag due to over pressure.
- Only use the charger (5V 1A, not included) to recharge the eye massager.
- You must have your eyes closed while massaging.
- DO NOT use sharp objects to scratch this product
Product structure
Technical parameters
- Product name: RENPHO Eye Massager with Remote
- Model: RF-EM001R
- Input: 5V=1A
- Rated voltage: 3.7V
- Rated power: 5W
- Alkaline battery of remote: 23A/12V
- Color: White/ Black
What’s included
- 1x RENPHO Eye Massager
- 1x USB Cable
- 1x User Manual
- 1x Warranty Card
- 1x Remote
Wearing the device
Align the cloth cover to your eyes, put on the device, adjust the elastic band, adjust the device to the most comfortable position. Hold the power button for 3-5 seconds to turn on the eye massager
During operation
- Default Setting: Air Pressure + Heat + Music
- Default Timer: 15 minutes
Press power button on the device, or(MJon the remote to change mode:
Hold power button 3-5 seconds to turn on/off the eye massager. Gently press
power button to change modes. Audio voice will confirm mode change.
Charging
- Use the 5V mobile charger(not included) for charging your eye massager.
- Insert USB cable into the socket of the mobile charger.
- Softly insert the micro USB plug into the socket of the device, making sure the micro USB is inserted in the right direction.
- Plug the charger into power.
- While charging, the red LED indicator will show. When done charging, the LED will be green. The device will not work while charging is in progress.
- The charge duration will be 2-3 hours. Disconnect the power adapter after charging is complete.
Volume adjustment
A short press on the device or +/- on the remote to control volume, and the volume will turn up/down continuously, the volume change is No volume-volume 1-volume 2-volume 3-volume 4- volume 5(max)+no volume.
Wireless/BT pairing
Hold ” on the device for 3 seconds,or single press””on the remote to enter
Wireless/BT pairing mode, on your phone or tablet enter your Wireless/BT
settings and select “eye massager” to connect. To quit the wireless/BT pairing
mode, hold “( on device for 3 seconds,or single press” on the remote till the
LED indicator stop flashing.
FAQ and troubleshooting
Problem | Possible causes | Actions |
---|
There is a sound mechanical or air sound coming from device| Normal sound of air pump inflating, motor working , or air pressure|
No need to do anything
Device turns off automatically . Device does not turn on .
Buttons are not responsive. Air pressure is weak .
|
1. Battery is Low.
2. The 15 mintues timer.
|
1 . Charge the device . 2 . Turn on the
massager again .
If there are other problems, turn off the device and contact us at support@rerpho.com. RENPHO is not responsible for any damage or injuries that occur if you attempt to disassemble or repair the product yourself.
Cleaning and maintenance
Please turn off the power when cleaning, do not use corrosive detergents such as benzene or diluents to clean the product. Do not expose the device to excessive sun or hot temperatures.
Guarantee
This product comes with a two-year warranty from the date of purchase. Warranty will be voided due to any of the following: Damaged due to improper usage or storage. Damaged by attempting to repair or disassemble the device. Period of warranty exceeded.
Notice:
This symbol on the device or itS packaging indicates: Do not dispose or
electrical appliances as unsorted municipal waste; use separate collection
facilities. Contact your local authority for information regarding the
collection systems available. If electrical appliances are disposed of in
landfills or dumps, hazardous substances can leak into the groundwater and get
into the food chain, damaging your health and well-being. When replacing old
appliances with new ones, the retailer is legally obliged to take back your
old appliance for disposal at least free of charge.
Declaration of Conformity
We (EU Representative is responsible for this declaration)
-BellaCocool GmbH1 (Company name) Pettenkoferstraße 18 10247, Berlin, Germany_ (Company address) declare under our sole responsibility that the product Tradename: RENPHO Equipment:EYE MASSAGER Model No. : RF-EM001R to which this declaration relates is in conformity with the essential requirement set out in the Council Directive on the Approximation of the laws of the Member States relating to CE-RED 2014/53/EU ) &RoHS(2002/95/EC) product is responsible to affix CE marking, the following standards were applied
- EN 62368-1:2014+A11:2017
- EN 624792010
- ETSI EN301489-1 V2.2.3(2019-11)
- ETSI EN301489-17 V3.1.1(2017-02)
- ETSI EN 300328 V2.2.2(2019-07)
- EN 60335-1:2012+A11:2014+A13:2017 +A1:2019+A2:2019+A14:2019
- EN 60335-2-32:2003+A1:2008+A2:2015
- EN 62233:2008
- IEC 62321 Series
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Warning: Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures.
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
RF warning statement
The device has been evaluated to meet general RF exposure requirements. The
device can be used in portable exposure conditions without restriction.
JOICO cORPORATION
Address: 165 E. Freedom Ave., Anaheim, CA 92801
Richers & Vision Ltd.
Address: Unit 58B, Bordon Enterprise Park Budds Lane, Bordon, Hampshire, GU35
0JE, U.K.
BellaCocool GmbH
Address: Pettenkoferstraße 18, 10247, Berlin, Germany
Shenzhen Runfeng Digital Technology Co., LTD
Address: Chuanghui Building, Intersection of Banxuegang Boulevard and
Yongxiang Road, Bantian Subdistrict, Longgang District, Shenzhen, Guangdong,
China
E-mail: support@renpho.com
support-eu@renpho.com
support-jp@renpho.com
Web: https://www.renpho.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>