ST eFuse (electronic fuse) User Guide

June 5, 2024
ST

ST eFuse (electronic fuse) User Guide

GLOSSARY AND DEVELOPMENT TOOLS

Accuracy – the maximum deviation from the specified over voltage, and over current protection levels.

Auto-retry – an auto-retrying device will turn itself back on after a thermal shutdown once the die temperature is below the hysteresis value.

Bias current – the current needed by the eFuse itself to maintain operation.

Overload current limit, or current limit trip-point – the eFuse reacts to overcurrent events by reducing the conductivity of the pass element once the current exceeds this limit

Short circuit current – when a strong overload occurs and the output voltage drops as a consequence, the device limits the current to a level below the regular current limit.

dV/dT – this refers to the internal circuitry that controls the output voltage rise at turn-on. The external dV/dT pin allows the user to adjust the soft-start time.

Enable-fault – the enable-fault pin is a dual-function pin: it lets the user enable and disable the device, and at the same time provides the device status through a three-state logic

Gate driver – to protect the supply and pass element, STEF01 and STEF12S include an internal charge pump to drive an external MOSFET that prevents reverse currents and large transient voltages which may occur during high- current limiting.

Hysteresis – to prevent an auto-retrying device from repeatedly turning ON and OFF after a thermal shutdown, the device only turns back on once the temperature has dropped by the hysteretic value.

Latch – when a thermal fault occurs, the device will remain OFF until the power or enable-signal is cycled by the user.

Output Voltage Clamp – if the input voltage exceeds the pre-defined voltage  clamp value, the internal protection circuit ensures the output voltage does not rise above this preset value.

Pass element – the voltage and current pass through a low-resistive power MOSFET which can be controlled to limit the output current and voltage in reaction to fault conditions.

Power dissipation – during normal operation, the power dissipated by the device depends on the pass element’s RDS(on) and the load current. When voltage/current is regulated, which happens during start-up and in case of faults, the excess power is dissipated in the form of heat. In persistent faulty conditions, this heat shuts the device down as a consequence of thermal protection.Thermal design and correct soft-start configurations are important to prevent unwanted shutdowns, which are most likely to occur during start-up phases or in high and continuous current conditions.

Power Good (PG) – a signal to indicate that the output voltage is very close to  the input and that no current/voltage limitation is in place. It can be used for power-sequencing, reset-triggering, and more.

Soft Start (SS) – a Soft Start is a controlled delivery of the output power , which minimizes inrush currents, thus protecting the power supply from overloading. The Soft Start time can be extended by adding a capacitor to the dV/dT pin.

Thermal shutdown – during a persistent fault, the eFuse die will heat up. Once the shutdown temperature (typically 175°C) is reached, the device will turn off the internal pass element and go in latch or auto-retry state.

UVLO (Undervoltage lockout) – the UVLO makes sure the device does not turn on until the supply voltage is high enough, thus contributing to the eFuse’s predictable and reliable performance.

DEMOBOARDS

Part number Product Description
STEVAL-EFUSE01 STEF01 Evaluation board based on the STEF01 fully

programmable universal electronic fuse
STEVAL-IFP021V1| STEF12/STEF05| 5 V and 12 V power line protection based on STEF05 and STEF12 electronic fuses

For more information, visit us on www.st.com/efuse

Ensuring safer designs and more efficient applications

HOW DOES AN eFuse WORK ?

An eFuse is a low-resistance switch connected in series to the main power rail and controlled by logic circuitry to protect loads and power supplies. Smaller, faster and more efficient than conventional fuses or polymeric PTCs, eFuses detect and react to overcurrent and overvoltage conditions, and do not require replacement after a fault event.

Main power rail

When an overload or short-circuit condition occurs, the eFuse limits the current to a pre-defined safe value. When an overvoltage condition occurs, the eFuse clamps the output voltage to a safe level,thus protecting the load from abnormalities caused by malfunctioning power supplies. The eFuse disconnects the load from the power supply if fault conditions are persistent. Depending on the version, the device operates either in latch-off mode, which means it is switched-off and must be re-armed manually, or in auto-retry mode where the device will automatically re-start.

KEY BENEFITS OF ELECTRONIC FUSES

Quick and intelligent response to faults

Unlike conventional fuses, which are based on the principle that a conductor will overheat and melt during an overload condition, the eFuse only clamps the output voltage and/or limits the throughput current, thus allowing the device to be supplied correctly, before eventually disconnecting the load in case of persistent failure. This prevents load and supply damage from occurring and avoids false triggering caused by transient conditions. Moreover, in applications powered by DC buses, eFuses reduce the bus droop due to faulty loads, avoiding the propagation of nuisance or undervoltage to other loads connected to the same bus.

Reduced maintenance
Since eFuses do not sacrifice their pass element, they can immediately be reset with a signal from the system by either cycling the supply power or by simply waiting, if auto-retry is used. The equipment’s uptime is maximized and the cost and complexity of maintenance are reduced.

Inrush current control
Inrush current conditions can occur during start-up or hot-plugging. eFuses ramp the output voltage up in a controlled manner to prevent large inrush currents from overloading the power supply. This feature is crucial when multiple loads are supplied by a single power supply

Flexible application design
Every eFuse can be programmed and tailored to your specific needs. Most eFuses allow users to set the current limit and start-up time. The undervoltage lockout and output clamp levels as well as the device’s operating mode (latch- off or auto-retry mode) can also be configured on certain part numbers.

KEY FEATURES

Output voltage clamping
Each eFuse has a predefined maximum output voltage safe value. If the input voltage exceeds this value, the eFuse clamps the output voltage to the preset value and allows the device to operate without damaging the load or system.If the overvoltage is persistent, the eFuse  disconnects the load.Most eFuses have a pre-set voltage clamp value. The STEF01 allows users to configure it.

Output voltage clamping

Current limiting
When an overload condition occurs, the eFuse reduces the conductivity of the internal pass element to effectively limit the current to a pre configured value. If a strong overload or short circuit occurs, the device enters the foldback current limit, and eventually disconnects the load, thus protecting the power supply. This value is usually configured using an external resistor.

Graph curve

Undervoltage lockout
The undervoltage lockout feature disconnects the load from the supply if the input voltage is lower than a preset minimum. By avoiding issues caused by too low supply voltage such as wrong voltages from bandgap references, incorrect control signals in logical circuitry, and transistors being only partially ON or OFF, the undervoltage lockout increases system predictability.The STEF01 allows users to set the undervoltage lockout threshold between 8 V and 45 V

Graph curve

Turn-on delay/Soft start
The eFuse provides a defined and predictable ramp-up of the output voltage during start-up, to ensure the inrush current is maintained within safe confines and protects both the load and the power supply.The soft start duration can be easily configured by an external capacitor.

Graph curve

Enable/Fault pin
All eFuses feature an enable/disable pin, to turn-on/off the device. In addition, some products offer the enable/fault pin, which is a dual-function pin that allows users to manually turn the output off and to read the current state of the device. The eFuse can be reset by toggling this pin after a thermal shutdown. The pin can be used as a regular enabling pin and can be connected to a monitoring circuit to notify thermal shutdown events. It can also be connected to the Enable/Fault pins of other eFuses, to achieve a simultaneous Enable/Disable operation for all devices.

PACKAGE RANGE

Package range

eFuses PORTFOLIO OVERVIEW

High Power

  • SERVER
  • TLC infrastructures
  • Industrial controls
  • NAS/SAN

12 V| STEF12H60M| 12 V, 60 A High precision eFuse with 0.85 mW RDSON current and temperature monitor pins. Parallel configuration. QFN 32 5×5 package
---|---|---
48 V| STEF01| 8 – 48 V, 4 – 5 A Fully programmable eFuse with 30 mW RDSON HTSSOP14 package

Low Power

  • Data-storage
  • Industrial
  • Consumer

12 V| STEF12S| 12 V, 4 A high-precision simple eFuse TSOT23-8L and DFN 3×3 packages
---|---|---
5 V| STEF05S| 5 V, 4 A high-precision simple eFuse TSOT23-8L package
Dual| STEF512GR| 5 V + 12V in one 3 A eFuse TSOT23-8L package
 | STEF512PUR| 5 V + 12 V in one 3 A eFuse with current monitor QFN 2×3 package
 | STEF512SR| 5 V + 12 V in one 3 A eFuse with reverse current protection on 5V channel DFN 2×3 package

eFuses portfolio overview

Legends: