Dear customers:
Thanks for choosing our cold spark machines, pls read the user manual carefully before using it to get a better user experience.

  1. Due to the manual content limited, pls understand missed some of the detail and safety directions in using, and did not undertake responsibility for the use result for missing.
  2. We will continue to focus on product research, development, and technical improvement to create better experience effects, so we reserve the right to make changes to the products, not to inform, the manual just for your reference, the final based on the products you received.

Package Contents

Included in delivery:

  • 1 x cold spark machine;
  • 1 x power cord;
  • 1 x signal cable;
  • 1 x remote controller

DMX Instruction

  1. The machine adopts a 3-pin signal wire connection (5-pin can be customized), with DMX IN and DMX OUT double interfaces, which can be used for multiple connections and is suitable for standard 512 signal control.
  2. Please refer to the attached for the channel occupied by DMX and its description
  3. DMX address code adjustment. : Means increasing DMX address code; long press helps increase fast.
    : Means decreasing DMX address code; long press helps decrease fast.

Note: When using DMX 512 signal control mode, each device is connected through the DMX signal socket INPUT and OUTPUT of the device. The 3-pin XLRXL plug terminals of the connected device must correspond to each other. It is recommended to use DMX signal terminators when connecting device signals, and using double-stranded shielded cables can avoid signal interference.

Indicator Description

MOKA SFX Mk e11 Ground 750W Cold Spark Machines - Fig
2

READY: Green light When the “READY” green light turns from flashing into the light on, it indicates that the machine is ready to work.
DMX: Blue light Flashing shows that the DMX signal is connected, otherwise is no signal.
FAULT: Yellow light The light is on with any malfunction.
HEAT: Red light When the machine is heating, the signal light is on.

Remote Controller

MOKA SFX Mk e11 Ground 750W Cold Spark Machines - Remote
Controller

  1. Suitable model instruction: this remote controller is suitable for all models with remote functions.
  2. Suitable machines instruction: the remote controller be suitable for the new machines, which already updated program, this remote also can control previous machines, but just do the basic control functions, and cannot realize special effects, which functions shown in the black line.
  3. Buttons usage instruction: the remote controller includes two parts, one for basic functions, and another for special effects(the functions within a black line)
    ➊. Power: (signal connection)short press 1second is connect the machine, and the display will show “FHH” after connection, then “FHH” will change to the special effects address as below show, that’s connected successfully. Long press 3 seconds is unconnected, the display shows “OFF”, then change to “001” as below:

Signal connected successfully| MOKA SFX Mk e11 Ground 750W Cold Spark
Machines - Fig 3
---|---
Signal unconnected|

➋. HEAT ON/OFF: (Heat ON/OFF) press the button start to heating, the red indicator light will lighting, and the display will show the heating temperature; long press 3 seconds to stop heating, and the heat indicator is off, show the address code of the special effects.
➌. STOP: (Emergency stop) stop do fountain.
➍. CLE: (Clear powder) the machine will clear powder for 30 seconds automatically. (pls pour out the rest powder from the powder box of a machine before doing this function)
➎. HIGH1/HIGH2/HIGH3: (Fountain height) high 1 – fountain lowest, high 3- fountain highest
➏. Speed: (Fountain time adjustment) multi-machines do fountain effects, the fountain time of each machine is 1-3seconds, and can be adjusted by a short press before doing the fountain.
➐. L-R A: from left to right each machine does a fountain on the sequence.
➑. LR-M A: from the left & right side to the middle, there have two machines doing the fountain at the same time.
➒. M-LR A: from the middle to the left & right sides, there have two machines fountain at the same time.
➓. L-R B: from left to right increase one machine to the fountain, till all the machines in the fountain.
⓫. LR-M B: from the left & right sides to the middle increase two machines do the fountain, till all the machines in the fountain.
⓬. M-LR B: from middle to left & right sides increase two machines do fountain, till all the machines in the fountain.
⓭. HIGH1/2/3: do special effects that can adjust fountain height, will show different fountain height presses every time.
⓮. +NO.-: the number of machines is adjusted, how many machines you need to use, then adjust the same number as used, the maximum add to fifteen machines.

Operation Instruction

There have two operation modes: DMX 512 console, remote controller

  1. Use the remote to do normal fountain:
    ➊. Connect the power cable of the machine, then turn on the green button.
    ➋. Press “power” to connect the machine, and the display shows “FHH” that be connected successfully.
    ➌. Press “HEAT ON/OFF” and start to heat till the green indicator light is always in the lighting.
    ➍. Press “HIGH1/HIGH2/HIGH3” to do the fountain.

  2. User remote do special effects fountain:
    ➊. Connect the power cable of the machine, then turn on the green button on the green.
    ➋. Press “power” to connect the machine, and the display shows “FHH” that be connected successfully.
    ➌.To adjust each machine’s special effects address code by each machine address code button as the picture show ; the display will show the number or letter(A、B、C、D、E、F are corresponding number10 to 15 respectively), like the below picture show “3” means this is the third machine.MOKA SFX Mk e11
Ground 750W Cold Spark Machines - Fig 6➍. Press “+NO.-” to adjust the number of machines to be used, and the display will show a number or letter(A、B、C、D、E、F corresponding numbers 10 to 15 respectively), as the below picture shows the right number “4” means total machines qty, the number must be adjusted to meet you need used machines qty. ➎. Press the “Heat ON/OFF” button to start to heat, till the green indicator light is always in the lighting, then can do the fountain, and the display will show the heating temperature.
    ➏. Press special effects A or B buttons will have related special effects.
    Eg: there have eight machines that do special effects, then the program will show as below: F18 F28 F38 F48 F58 F68 F78 F88

  3. Console operation:
    ➊. Connect the power cable and DMX signal cables of the machine, turn on the green button, and DMX blue indicator light in lighting, then connected the DMX signal successfully.
    ➋. The first channel pushes to the top and starts heating, till the green indicator light is always in lighting, then can do fountain.
    ➌. Push the second channel to the fountain.

Remark: For the detailed channel instruction, pls refer to the attached chain operation; if need uses the console to do special effects, then need to do the program by yourself.

Consumables

  1. The consumables are classified as:
    SMALL: the spark fountain height is 1.0-3.5m (error 0.5m), and the spot is rarely dropped, used indoors.
    LARGE: the spark fountain height is 2.0-5.0m (error 0.5m), and the sprayed spot has dropped ground, used for outdoor.

  2. Consumables choice: Consumables are the customized formula for the test of our machines. Please select our consumables to avoid affecting the effect of machine; (No warranty service is provided for machine damage caused by consumables, not from our company).

  3. Consumables save: Consumables should be kept in a dry and sealed environment to prevent moisture. (wet and sundry consumables should not be used)

  4. Consumables add: Pls stop running the machines before adding the consumables, to avoid accidental injury.

Clean and Maintenance

  1. Clear powder: Pls empty the remaining consumables after use, and power on using the Clear Powder process to clear the remaining material by remote controller or DMX controller. (Note: problems caused by improper cleaning will not be covered by the free warranty).
  2. Dust net cleaning: Please clean the dust net regularly, to avoid blocking the dust net and influencing heat dissipation of the machine. (The dust on the screen can be removed directly from the outside)
  3. External cleaning: Please wipe the machine gently with soft cotton, to avoid scratching the machine housing.
  4. Internal cleaning: There has a clear hole at the bottom of the machine, through which the internal dust can be poured out.

After-sales

  1. Warranty: 1 Year (Subject to the date of manufacture)
  2. Each machine is affixed with the factory code. The factory code shall be provided when enjoying the warranty service. It is invalid if torn.
  3. It’s may need to provide some videos or pictures to confirm the problems.

Fault light (yellow) display and processing method

Display content Fault causes Solution
E01 Heating failure 1: Check if the heat dissipation plate is normal. 2:

Replace the heat dissipation plate or heating board.
E02| The heating is not controlled| Replace the heating board.
E03| The internal temperature of the machine is extremely high| 1: Check the cooling fan.
2: stop heating and operating, restart after 10 minutes.
E04| The air blower does not work| 1: Check if there is any foreign object falling into the nozzle. 2: Replace the air blower motor.
E05| The sensor is faulty| 1: Check the sensor socket. 2: replace the sensor.
E6| The anti-tilt safety function is enabled| 1: Pls restart the machine, don’t tilt the machine again after powering it on.
E07| Safety protection of blower motor| Shut down the machine to check whether the blower motor is working properly

Note: when the fault light is on, pls turn off the power of the machine in time, to avoid extra damage, and users are expected to restart the machine until the fault light is off.

Warnings and Cautions

**** Warning: High-temperature warning, high temperature at the exit.
**** The hole for adding powder
**** The sign is to remind users of paying attention to risk and security.

Please note that the machines are not meant to be a continuous duration effect. The maximum running time is 30 seconds and can be repeated but should not be done to overheat the machine.
| The eye protection warning sign is to remind you to protect the eyes during the machine operation.
| Warning: Dangerous voltages are present in this machine when electrical power is applied. There is a danger of injury from electric shock. Under no circumstances are you to attempt to open the machine or attempt to remove or adjust any components fitted within the machine.
Only fully trained engineers can open the equipment.
| Use caution so that any liquids do not wet the machine. Keep the machine and controller dry and do not use rainy or snowy days unless covered.
Cleanin g| Please inspect the fountain nozzle before use and confirm whether there is accumulation granulates. If it does, please clean out by inverting the machine to clean out the port.

  1. The machine’s built-in protection procedures will stop the auto. once do fountain over the 30s each time. If need it to work again, please operate the second channel again. If the continuous shooting time is too long, the internal temperature will rise sharply and cause permanent damage. Suggest not doing continuous shooting over 1minutes.
  2. Max connection is 6 pieces via power connecting cables, too many devices working together will cause damage or fire.
  3. If there is no spark out with enough consumables or other abnormal situation, pls stop running the machine and contact after-sale service for help.
  4. After use, the machines, do not immediately turn off the power. The heat-dissipating fan should take out the internal air when the power is on. Otherwise, the internal heat is quickly transmitted to the surface of the housing.
  5. Please place the equipment in an open place and keep a safe distance of more than 5 meters from the personnel.
  6. Make sure the device is off before filling the consumables
  7. If the consumables are accidentally ignited, please use the sand to extinguish them, do not use water.
  8. Damage caused by improper use or human factors is not covered by the warranty.
  9. The final interpretation right belongs to our company.

Attached as below
Ground Big 750W

MOKA SFX Mk e11 Ground 750W Cold Spark Machines - Ground
Big

Outlook function description

1| QC| 8| Remote receiver signal| 15| Dust net
2| Cooling fan| 9| Display| 16| Spray hole
3| Indicator| 10| Adjust buttons| 17| Powder hole
4| Fuse| 11| Parameter label| 18| Pads
5| Power switch| 12| DMX port| 19| Cleaning hole
6| Power port| 13| Foldable handle| |
7| Factory code| 14| Access hole| |
Product Parameters

Working Height| 1-5m| Interface| Double DMX input, Double AC power
Fountain direction| Up| Control mode| DMX / Remote
Working Temperature| -10°C-50t| Housing material| Aluminum
Heating Power| 750w 6.8A(110V) 750w 3.4A (220V)| N.W| 7.8kg
Fuse| 110V/10A, 220V/6A| Size| 220250310mm
DMX Channel (2 Channels)

1st channel| 0-10| 11-220| 221-239| 240-255| |
Function| Pre-heat turn-off| Emergency stop| Clear Powder| Pre-heat turn on| |
Display| Add. code| 0.00E+00| CLE| 0-500| |
2nd channel| 0-15| 16-39| 40-63| 64-87| 88-111| 112-135
Function| Turn off| Fountain 1| Fountain 2| Fountain 3| Fountain 4| Fountai n5
Display| OFF| Fl| F2| F3| F4| F5
2nd channel| 136-159| 160-183| 184-207| 208-231| 232-255|
Function| Fountain 6| Fountain 7| Fountain 8| Fountain 9| Fountain 10|
Display| F6| F7| F8| F9| F10|